Comparison of real data and simulated data analysis of a stopping rule based on the standard error of measurement in computerized adaptive testing for medical examinations in Korea: a psychometric study.
{"title":"Comparison of real data and simulated data analysis of a stopping rule based on the standard error of measurement in computerized adaptive testing for medical examinations in Korea: a psychometric study.","authors":"Dong Gi Seo, Jeongwook Choi, Jinha Kim","doi":"10.3352/jeehp.2024.21.18","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study aimed to compare and evaluate the efficiency and accuracy of computerized adaptive testing (CAT) under 2 stopping rules (standard error of measurement [SEM]=0.3 and 0.25) using both real and simulated data in medical examinations in Korea.</p><p><strong>Methods: </strong>This study employed post-hoc simulation and real data analysis to explore the optimal stopping rule for CAT in medical examinations. The real data were obtained from the responses of 3rd-year medical students during examinations in 2020 at Hallym University College of Medicine. Simulated data were generated using estimated parameters from a real item bank in R. Outcome variables included the number of examinees’ passing or failing with SEM values of 0.25 and 0.30, the number of items administered, and the correlation. The consistency of real CAT result was evaluated by examining consistency of pass or fail based on a cut score of 0.0. The efficiency of all CAT designs was assessed by comparing the average number of items administered under both stopping rules.</p><p><strong>Results: </strong>Both SEM 0.25 and SEM 0.30 provided a good balance between accuracy and efficiency in CAT. The real data showed minimal differences in pass/ fail outcomes between the 2 SEM conditions, with a high correlation (r=0.99) between ability estimates. The simulation results confirmed these findings, indicating similar average item numbers between real and simulated data.</p><p><strong>Conclusion: </strong>The findings suggest that both SEM 0.25 and 0.30 are effective termination criteria in the context of the Rasch model, balancing accuracy and efficiency in CAT.</p>","PeriodicalId":46098,"journal":{"name":"Journal of Educational Evaluation for Health Professions","volume":"21 ","pages":"18"},"PeriodicalIF":9.3000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Educational Evaluation for Health Professions","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3352/jeehp.2024.21.18","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/9 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"EDUCATION, SCIENTIFIC DISCIPLINES","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: This study aimed to compare and evaluate the efficiency and accuracy of computerized adaptive testing (CAT) under 2 stopping rules (standard error of measurement [SEM]=0.3 and 0.25) using both real and simulated data in medical examinations in Korea.
Methods: This study employed post-hoc simulation and real data analysis to explore the optimal stopping rule for CAT in medical examinations. The real data were obtained from the responses of 3rd-year medical students during examinations in 2020 at Hallym University College of Medicine. Simulated data were generated using estimated parameters from a real item bank in R. Outcome variables included the number of examinees’ passing or failing with SEM values of 0.25 and 0.30, the number of items administered, and the correlation. The consistency of real CAT result was evaluated by examining consistency of pass or fail based on a cut score of 0.0. The efficiency of all CAT designs was assessed by comparing the average number of items administered under both stopping rules.
Results: Both SEM 0.25 and SEM 0.30 provided a good balance between accuracy and efficiency in CAT. The real data showed minimal differences in pass/ fail outcomes between the 2 SEM conditions, with a high correlation (r=0.99) between ability estimates. The simulation results confirmed these findings, indicating similar average item numbers between real and simulated data.
Conclusion: The findings suggest that both SEM 0.25 and 0.30 are effective termination criteria in the context of the Rasch model, balancing accuracy and efficiency in CAT.
期刊介绍:
Journal of Educational Evaluation for Health Professions aims to provide readers the state-of-the art practical information on the educational evaluation for health professions so that to increase the quality of undergraduate, graduate, and continuing education. It is specialized in educational evaluation including adoption of measurement theory to medical health education, promotion of high stakes examination such as national licensing examinations, improvement of nationwide or international programs of education, computer-based testing, computerized adaptive testing, and medical health regulatory bodies. Its field comprises a variety of professions that address public medical health as following but not limited to: Care workers Dental hygienists Dental technicians Dentists Dietitians Emergency medical technicians Health educators Medical record technicians Medical technologists Midwives Nurses Nursing aides Occupational therapists Opticians Oriental medical doctors Oriental medicine dispensers Oriental pharmacists Pharmacists Physical therapists Physicians Prosthetists and Orthotists Radiological technologists Rehabilitation counselor Sanitary technicians Speech-language therapists.