Corneal densitometry changes after femtosecond laser-assisted intracorneal ring segments implantation in keratoconus.

Q2 Medicine
Amr Mounir, Engy Mohamed Mostafa, Ibrahim Amer, Ahmed Abdelaleem Abdelgbar, Hamdy Osman Osman, Mostafa Abdelrahman Ahmed, Hossam Ziada, Abdel Ghany Ali El Gabbar, Mohamed Alsadawy Hassan, Alaa Mahmoud
{"title":"Corneal densitometry changes after femtosecond laser-assisted intracorneal ring segments implantation in keratoconus.","authors":"Amr Mounir, Engy Mohamed Mostafa, Ibrahim Amer, Ahmed Abdelaleem Abdelgbar, Hamdy Osman Osman, Mostafa Abdelrahman Ahmed, Hossam Ziada, Abdel Ghany Ali El Gabbar, Mohamed Alsadawy Hassan, Alaa Mahmoud","doi":"10.51329/mehdiophthal1491","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Intrastromal corneal ring segments are commonly implanted in the corneas of eyes with mild-to-moderate keratoconus; however, changes in corneal densitometry (CD) after implantation are a matter of debate in the current literature. We evaluated the changes in CD 1 and 3 months after femtosecond laser-assisted Keraring implantation.</p><p><strong>Methods: </strong>This retrospective, non-comparative, multicenter, case series study included patients with keratoconus who underwent femtosecond laser-assisted implantation of double segments with 90° and 160° arc lengths or two 160° arc length Keraring segments. Demographic and baseline clinical ophthalmic data were recorded. Corneal topography and tomography data acquired using a Pentacam HR Scheimpflug tomography system (Pentacam High Resolution; Oculus, Wetzlar, Germany) with a best-fit sphere were used as a reference surface. Using the Pentacam HR, CD measurements were acquired over a corneal area of 12 mm in total and at four concentric zones (0-2, 2-6, 6-10, and 10-12 mm) of three corneal stromal depths: 120 μm of the anterior corneal stromal layer, 60 μm of the posterior corneal stromal layer, and the central layer of stroma lying between these two layers.</p><p><strong>Results: </strong>We included 40 eyes of 40 patients, including 8 (20%) male and 32 (80%) female individuals, with a mean (standard deviation) age of 21.0 (6.4) years. We observed a significant improvement in the topographic values of steep keratometry (K), flat K, maximum K, and corneal astigmatism (all P < 0.05), but not in the mean K, thinnest corneal pachymetry, corneal thickness at the apex, back elevation, or front elevation (all P > 0.05). The mean total anterior, central, and posterior CD differed significantly among the time points, with a significant increase from the preoperative to the 1-month and 3-month postoperative visits (all P < 0.05) and no difference between those of the 1-month and 3-month postoperative visits (all P > 0.05). The mean CD for the anterior layer in the central, paracentral, and mid-peripheral zones, and the central layer in all four zones, differed significantly among time points, with a significant increase from the preoperative to the 1-month and 3-month postoperative visits (all P < 0.05), which remained unchanged from the 1-month to the 3-month postoperative visit (all P < 0.05), except for the central 2-6-mm zone, which decreased significantly from the 1-month to the 3-month postoperative visit (P < 0.001). The CD of the central 10-12-mm zone did not differ significantly in each pairwise comparison (all P > 0.05). In contrast, CD for the posterior layer in the paracentral zone decreased significantly from the preoperative to the 1-month and 3-month postoperative visits but increased, to a lesser extent, from the 1-month to the 3-month postoperative visit (all P < 0.05).</p><p><strong>Conclusions: </strong>Femtosecond laser-assisted Keraring implantation significantly changes CD, with improvement in most topography parameters. Further longitudinal studies with larger sample sizes are required to verify these preliminary findings.</p>","PeriodicalId":36524,"journal":{"name":"Medical Hypothesis, Discovery, and Innovation in Ophthalmology","volume":"13 1","pages":"27-34"},"PeriodicalIF":0.0000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11227663/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical Hypothesis, Discovery, and Innovation in Ophthalmology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.51329/mehdiophthal1491","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Intrastromal corneal ring segments are commonly implanted in the corneas of eyes with mild-to-moderate keratoconus; however, changes in corneal densitometry (CD) after implantation are a matter of debate in the current literature. We evaluated the changes in CD 1 and 3 months after femtosecond laser-assisted Keraring implantation.

Methods: This retrospective, non-comparative, multicenter, case series study included patients with keratoconus who underwent femtosecond laser-assisted implantation of double segments with 90° and 160° arc lengths or two 160° arc length Keraring segments. Demographic and baseline clinical ophthalmic data were recorded. Corneal topography and tomography data acquired using a Pentacam HR Scheimpflug tomography system (Pentacam High Resolution; Oculus, Wetzlar, Germany) with a best-fit sphere were used as a reference surface. Using the Pentacam HR, CD measurements were acquired over a corneal area of 12 mm in total and at four concentric zones (0-2, 2-6, 6-10, and 10-12 mm) of three corneal stromal depths: 120 μm of the anterior corneal stromal layer, 60 μm of the posterior corneal stromal layer, and the central layer of stroma lying between these two layers.

Results: We included 40 eyes of 40 patients, including 8 (20%) male and 32 (80%) female individuals, with a mean (standard deviation) age of 21.0 (6.4) years. We observed a significant improvement in the topographic values of steep keratometry (K), flat K, maximum K, and corneal astigmatism (all P < 0.05), but not in the mean K, thinnest corneal pachymetry, corneal thickness at the apex, back elevation, or front elevation (all P > 0.05). The mean total anterior, central, and posterior CD differed significantly among the time points, with a significant increase from the preoperative to the 1-month and 3-month postoperative visits (all P < 0.05) and no difference between those of the 1-month and 3-month postoperative visits (all P > 0.05). The mean CD for the anterior layer in the central, paracentral, and mid-peripheral zones, and the central layer in all four zones, differed significantly among time points, with a significant increase from the preoperative to the 1-month and 3-month postoperative visits (all P < 0.05), which remained unchanged from the 1-month to the 3-month postoperative visit (all P < 0.05), except for the central 2-6-mm zone, which decreased significantly from the 1-month to the 3-month postoperative visit (P < 0.001). The CD of the central 10-12-mm zone did not differ significantly in each pairwise comparison (all P > 0.05). In contrast, CD for the posterior layer in the paracentral zone decreased significantly from the preoperative to the 1-month and 3-month postoperative visits but increased, to a lesser extent, from the 1-month to the 3-month postoperative visit (all P < 0.05).

Conclusions: Femtosecond laser-assisted Keraring implantation significantly changes CD, with improvement in most topography parameters. Further longitudinal studies with larger sample sizes are required to verify these preliminary findings.

飞秒激光辅助角膜内环节段植入术后角膜密度的变化。
背景:在轻度至中度角膜炎患者的角膜上通常会植入基质内角膜环段;然而,植入后角膜密度(CD)的变化在目前的文献中还存在争议。我们评估了飞秒激光辅助角膜塑形镜植入术后 1 个月和 3 个月 CD 的变化:这项回顾性、非比较性、多中心、病例系列研究纳入了在飞秒激光辅助下植入 90° 和 160° 弧长双节段或两个 160° 弧长 Keraring 节段的角膜炎患者。记录了人口统计学和眼科临床基线数据。使用 Pentacam HR Scheimpflug 层析成像系统(Pentacam 高分辨率;Oculus,德国,Wetzlar)采集的角膜地形图和层析成像数据以最佳拟合球面为参考面。使用 Pentacam HR,在总长度为 12 毫米的角膜区域和三个角膜基质深度的四个同心区(0-2、2-6、6-10 和 10-12 毫米)进行了 CD 测量:角膜前基质层 120 微米,角膜后基质层 60 微米,以及位于这两层之间的中央基质层:我们共纳入了 40 名患者的 40 只眼睛,其中男性 8 名(占 20%),女性 32 名(占 80%),平均年龄(标准差)为 21.0(6.4)岁。我们观察到,陡角膜度数(K)、平角膜度数、最大角膜度数和角膜散光的地形学值均有明显改善(P 均小于 0.05),但平均角膜度数、最薄角膜厚度、角膜顶点厚度、后方抬高和前方抬高的地形学值均无明显改善(P 均大于 0.05)。术前、术后 1 个月和 3 个月的前层、中央层和后层平均总 CD 值在不同时间点之间差异显著,术前显著增加(所有 P 均小于 0.05),术后 1 个月和 3 个月没有差异(所有 P 均大于 0.05)。中央区、旁中心区和中外周区前层以及所有四个区中央层的平均 CD 在不同时间点有显著差异,术前至术后 1 个月和 3 个月的平均 CD 显著增加(均 P < 0.05),从术后 1 个月到术后 3 个月就诊时保持不变(均 P <0.05),只有中央 2-6 mm 区从术后 1 个月到术后 3 个月就诊时明显减少(P <0.001)。中央 10-12 毫米区的 CD 在每对比较中均无明显差异(均 P > 0.05)。与此相反,旁中心区后层的 CD 从术前到术后 1 个月和 3 个月时明显减少,但从术后 1 个月到术后 3 个月时增加较少(均 P <0.05):结论:飞秒激光辅助下的 Keraring 植入术能显著改变 CD,改善大多数地形参数。要验证这些初步研究结果,还需要更多样本量的纵向研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
2.00
自引率
0.00%
发文量
19
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信