Measurement of the distance between tumor micro-foci and gross tumor in rectal cancer pathological specimens: implication on margin distance of clinical target volume treated with high-dose radiotherapy for rectal cancer.
Xu-Jie Bao, Xiao-Yan Chen, Lu Wen, Yuan-Yuan Liu, En-Hao Yu, Zheng Wu, Ke Liu, Ju-Mei Zhou, Su-Yu Zhu
{"title":"Measurement of the distance between tumor micro-foci and gross tumor in rectal cancer pathological specimens: implication on margin distance of clinical target volume treated with high-dose radiotherapy for rectal cancer.","authors":"Xu-Jie Bao, Xiao-Yan Chen, Lu Wen, Yuan-Yuan Liu, En-Hao Yu, Zheng Wu, Ke Liu, Ju-Mei Zhou, Su-Yu Zhu","doi":"10.1007/s10147-024-02582-4","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To measure the micro-foci distance away from gross tumor and to provide reference to create the clinical target volume (CTV) margin for boost radiotherapy in rectal adenocarcinoma.</p><p><strong>Methods: </strong>Twenty-eight rectal cancer surgical specimens of only total mesorectal excision were collected. The pathological specimens were retrospectively measured, and the nearest distance between the tumor micro-foci and gross tumor was microscopically measured. The \"in vivo-in vitro\" retraction factor was calculated as the ratio of the deepest thickness laterally and the vertical height superior/inferiorly of the rectal tumor measured in MRI and those measured in immediate pathological specimens. The retraction factor during pathological specimen processing was calculated as the distance ratio before and after dehydration in the lateral, superior, and inferior sides by the \"knot marking method.\" The distances of tumor micro-foci were individually corrected with these two retraction factors.</p><p><strong>Results: </strong>The mean \"in vivo-in vitro\" tumor retraction factors were 0.913 peripherally and 0.920 superior/inferiorly. The mean tumor specimen processing retraction factors were 0.804 peripherally, 0.815 inferiorly, and 0.789 superiorly. Of 28 patients, 14 cases (50.0%) had 24 lateral micro-foci, 8 cases (28.6%) had 13 inferior micro-foci, and 7 cases (25.0%) had 19 superior micro-foci. The 95th percentiles of the micro-foci distance for 28 patients were 6.44 mm (peripheral), 5.54 mm (inferior), and 5.42 mm (superior) after retraction correction.</p><p><strong>Conclusion: </strong>The micro-foci distances of 95% of rectal adenocarcinoma patients examined were within 6.44 mm peripherally, 5.54 mm inferiorly, and 5.42 mm superiorly. These findings provide reference to set the boost radiotherapy CTV margin for rectal cancer.</p>","PeriodicalId":13869,"journal":{"name":"International Journal of Clinical Oncology","volume":" ","pages":"1491-1499"},"PeriodicalIF":2.4000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11420390/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Clinical Oncology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10147-024-02582-4","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/8 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ONCOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: To measure the micro-foci distance away from gross tumor and to provide reference to create the clinical target volume (CTV) margin for boost radiotherapy in rectal adenocarcinoma.
Methods: Twenty-eight rectal cancer surgical specimens of only total mesorectal excision were collected. The pathological specimens were retrospectively measured, and the nearest distance between the tumor micro-foci and gross tumor was microscopically measured. The "in vivo-in vitro" retraction factor was calculated as the ratio of the deepest thickness laterally and the vertical height superior/inferiorly of the rectal tumor measured in MRI and those measured in immediate pathological specimens. The retraction factor during pathological specimen processing was calculated as the distance ratio before and after dehydration in the lateral, superior, and inferior sides by the "knot marking method." The distances of tumor micro-foci were individually corrected with these two retraction factors.
Results: The mean "in vivo-in vitro" tumor retraction factors were 0.913 peripherally and 0.920 superior/inferiorly. The mean tumor specimen processing retraction factors were 0.804 peripherally, 0.815 inferiorly, and 0.789 superiorly. Of 28 patients, 14 cases (50.0%) had 24 lateral micro-foci, 8 cases (28.6%) had 13 inferior micro-foci, and 7 cases (25.0%) had 19 superior micro-foci. The 95th percentiles of the micro-foci distance for 28 patients were 6.44 mm (peripheral), 5.54 mm (inferior), and 5.42 mm (superior) after retraction correction.
Conclusion: The micro-foci distances of 95% of rectal adenocarcinoma patients examined were within 6.44 mm peripherally, 5.54 mm inferiorly, and 5.42 mm superiorly. These findings provide reference to set the boost radiotherapy CTV margin for rectal cancer.
期刊介绍:
The International Journal of Clinical Oncology (IJCO) welcomes original research papers on all aspects of clinical oncology that report the results of novel and timely investigations. Reports on clinical trials are encouraged. Experimental studies will also be accepted if they have obvious relevance to clinical oncology. Membership in the Japan Society of Clinical Oncology is not a prerequisite for submission to the journal. Papers are received on the understanding that: their contents have not been published in whole or in part elsewhere; that they are subject to peer review by at least two referees and the Editors, and to editorial revision of the language and contents; and that the Editors are responsible for their acceptance, rejection, and order of publication.