{"title":"Response characteristics of PWR primary circuit under SBLOCAs considering steam bypass discharging","authors":"Shuai Yang, Xiang-Bin Li, Yu-Sheng Liu, Jia‑Ning Xu, De‑Chen Zhang","doi":"10.1007/s41365-024-01457-7","DOIUrl":null,"url":null,"abstract":"<p>Small-break superposed station blackout (SBO) accidents are the basic design accidents of nuclear power plants. Under the condition of a small break in the cold leg, SBO further increases the severity of the accident, and the steam bypass discharging system (GCT) in the second circuit can play an important role in guaranteeing core safety. To explore the influence of the GCT on the thermal–hydraulic characteristics of the primary circuit, RELAP5 software was used to establish a numerical model based on a typical pressurized water reactor nuclear power plant. Five different small breaks in the cold-leg superposed SBO were selected, and the impact of the GCT operation on the transient response characteristics of the primary and secondary circuit systems was analyzed. The results show that the GCT plays an indispensable role in core heat removal during an accident; otherwise, core safety cannot be guaranteed. The GCT was used in conjunction with the primary safety injection system during the placement process. When the break diameter was greater than a certain critical value, the core cooling rate could not be guaranteed to be less than 100 K/h; however, the core remained in a safe state.</p>","PeriodicalId":19177,"journal":{"name":"Nuclear Science and Techniques","volume":"15 1","pages":""},"PeriodicalIF":3.6000,"publicationDate":"2024-06-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nuclear Science and Techniques","FirstCategoryId":"101","ListUrlMain":"https://doi.org/10.1007/s41365-024-01457-7","RegionNum":1,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"NUCLEAR SCIENCE & TECHNOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Small-break superposed station blackout (SBO) accidents are the basic design accidents of nuclear power plants. Under the condition of a small break in the cold leg, SBO further increases the severity of the accident, and the steam bypass discharging system (GCT) in the second circuit can play an important role in guaranteeing core safety. To explore the influence of the GCT on the thermal–hydraulic characteristics of the primary circuit, RELAP5 software was used to establish a numerical model based on a typical pressurized water reactor nuclear power plant. Five different small breaks in the cold-leg superposed SBO were selected, and the impact of the GCT operation on the transient response characteristics of the primary and secondary circuit systems was analyzed. The results show that the GCT plays an indispensable role in core heat removal during an accident; otherwise, core safety cannot be guaranteed. The GCT was used in conjunction with the primary safety injection system during the placement process. When the break diameter was greater than a certain critical value, the core cooling rate could not be guaranteed to be less than 100 K/h; however, the core remained in a safe state.
期刊介绍:
Nuclear Science and Techniques (NST) reports scientific findings, technical advances and important results in the fields of nuclear science and techniques. The aim of this periodical is to stimulate cross-fertilization of knowledge among scientists and engineers working in the fields of nuclear research.
Scope covers the following subjects:
• Synchrotron radiation applications, beamline technology;
• Accelerator, ray technology and applications;
• Nuclear chemistry, radiochemistry, radiopharmaceuticals, nuclear medicine;
• Nuclear electronics and instrumentation;
• Nuclear physics and interdisciplinary research;
• Nuclear energy science and engineering.