{"title":"Comparative assessment of two in-house-built isothermal assays for visual detection of African swine fever virus","authors":"Gyanendra Singh Sengar, Soumendu Chakravarti, Rajib Deb, Seema Rani Pegu, Pranav Anjaria, Joyshikh Sonowal, Swaraj Rajkhowa, Pranab Joyti Das, Vivek Kumar Gupta","doi":"10.1007/s12038-024-00451-w","DOIUrl":null,"url":null,"abstract":"<p>Owing to the lack of effective vaccines, current control measures and eradication strategies for the African swine fever virus (ASFV) rely on early detection and stringent stamping-out procedures. In the present study, we developed two independent isothermal amplification assays, namely, loop-mediated isothermal amplification (LAMP) and polymerase spiral reaction (PSR), for quick visualization of the ASFV genome in clinical samples. Additionally, a quantitative real-time PCR (qRT-PCR)-based hydrolysis probe assay was developed for comparative assessment of sensitivity with the developed isothermal assays. The analytical sensitivity of the LAMP, PSR, and qRT-PCR was found to be 2.64 ×10<sup>5</sup> copies/µL, 2.64 ×10<sup>2</sup> copies/µL, and 2.64 ×10<sup>1</sup> copies/µL, respectively. A total of 165 clinical samples was tested using the developed visual assays. The relative accuracy, relative specificity, and relative diagnostic sensitivity for LAMP vs PSR were found to be 95.37% vs 102.48%, 97.46% vs 101.36%, and 73.33% vs 113.33%, respectively.</p>","PeriodicalId":15171,"journal":{"name":"Journal of Biosciences","volume":"147 1","pages":""},"PeriodicalIF":2.1000,"publicationDate":"2024-06-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Biosciences","FirstCategoryId":"99","ListUrlMain":"https://doi.org/10.1007/s12038-024-00451-w","RegionNum":4,"RegionCategory":"生物学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"BIOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Owing to the lack of effective vaccines, current control measures and eradication strategies for the African swine fever virus (ASFV) rely on early detection and stringent stamping-out procedures. In the present study, we developed two independent isothermal amplification assays, namely, loop-mediated isothermal amplification (LAMP) and polymerase spiral reaction (PSR), for quick visualization of the ASFV genome in clinical samples. Additionally, a quantitative real-time PCR (qRT-PCR)-based hydrolysis probe assay was developed for comparative assessment of sensitivity with the developed isothermal assays. The analytical sensitivity of the LAMP, PSR, and qRT-PCR was found to be 2.64 ×105 copies/µL, 2.64 ×102 copies/µL, and 2.64 ×101 copies/µL, respectively. A total of 165 clinical samples was tested using the developed visual assays. The relative accuracy, relative specificity, and relative diagnostic sensitivity for LAMP vs PSR were found to be 95.37% vs 102.48%, 97.46% vs 101.36%, and 73.33% vs 113.33%, respectively.
期刊介绍:
The Journal of Biosciences is a quarterly journal published by the Indian Academy of Sciences, Bangalore. It covers all areas of Biology and is the premier journal in the country within its scope. It is indexed in Current Contents and other standard Biological and Medical databases. The Journal of Biosciences began in 1934 as the Proceedings of the Indian Academy of Sciences (Section B). This continued until 1978 when it was split into three parts : Proceedings-Animal Sciences, Proceedings-Plant Sciences and Proceedings-Experimental Biology. Proceedings-Experimental Biology was renamed Journal of Biosciences in 1979; and in 1991, Proceedings-Animal Sciences and Proceedings-Plant Sciences merged with it.