Self-Sampling by Adolescents at Home: Assessment of the Feasibility to Successfully Collect Blood Microsamples by Inexperienced Individuals.

IF 5 3区 医学 Q1 PHARMACOLOGY & PHARMACY
Laura Boffel, Anskje Van Mensel, Janne Pauwels, Elly Den Hond, Jos Bessems, Katleen Van Uytfanghe, Christophe P Stove
{"title":"Self-Sampling by Adolescents at Home: Assessment of the Feasibility to Successfully Collect Blood Microsamples by Inexperienced Individuals.","authors":"Laura Boffel, Anskje Van Mensel, Janne Pauwels, Elly Den Hond, Jos Bessems, Katleen Van Uytfanghe, Christophe P Stove","doi":"10.1208/s12248-024-00947-1","DOIUrl":null,"url":null,"abstract":"<p><p>Blood microsampling has increasingly attracted interest in the past decades as a more patient-centric sampling approach, offering the possibility to collect a minimal volume of blood following a finger or arm prick at home. In addition to conventional dried blood spots (DBS), many different devices allowing self-sampling of blood have become available. Obviously, the success of home-sampling can only be assured when (inexperienced) users collect samples of good quality. Therefore, the feasibility of six different microsampling devices to collect capillary blood by inexperienced adolescents at home was evaluated. Participants (n = 95) were randomly assigned to collect blood (dried or liquid) at different time points using four of six different self-sampling devices (i.e., DBS, Mitra volumetric absorptive microsampling (VAMS), Capitainer B, Tasso M20, Minicollect tube and Tasso<sup>+</sup> serum separator tube (SST)). The quality of the samples was visually inspected and analytically determined. Moreover, the participants' satisfaction was assessed via questionnaires. Although a majority succeeded based on the visual inspection, the success rate differed largely between the different devices. In general, the lowest success rate was obtained for the Minicollect tubes, although there is an opportunity and need for improvement for the other self-sampling devices as well. Hence, this also emphasizes the importance to assess the quality of samples collected by the target population prior to study initiation. In addition, visual classification by a trained individual was confirmed based on assessment of the analytical variability between replicates. Finally, self-sampling at home was overall (very) positively received by the participants.</p>","PeriodicalId":50934,"journal":{"name":"AAPS Journal","volume":"26 4","pages":"75"},"PeriodicalIF":5.0000,"publicationDate":"2024-07-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"AAPS Journal","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1208/s12248-024-00947-1","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"PHARMACOLOGY & PHARMACY","Score":null,"Total":0}
引用次数: 0

Abstract

Blood microsampling has increasingly attracted interest in the past decades as a more patient-centric sampling approach, offering the possibility to collect a minimal volume of blood following a finger or arm prick at home. In addition to conventional dried blood spots (DBS), many different devices allowing self-sampling of blood have become available. Obviously, the success of home-sampling can only be assured when (inexperienced) users collect samples of good quality. Therefore, the feasibility of six different microsampling devices to collect capillary blood by inexperienced adolescents at home was evaluated. Participants (n = 95) were randomly assigned to collect blood (dried or liquid) at different time points using four of six different self-sampling devices (i.e., DBS, Mitra volumetric absorptive microsampling (VAMS), Capitainer B, Tasso M20, Minicollect tube and Tasso+ serum separator tube (SST)). The quality of the samples was visually inspected and analytically determined. Moreover, the participants' satisfaction was assessed via questionnaires. Although a majority succeeded based on the visual inspection, the success rate differed largely between the different devices. In general, the lowest success rate was obtained for the Minicollect tubes, although there is an opportunity and need for improvement for the other self-sampling devices as well. Hence, this also emphasizes the importance to assess the quality of samples collected by the target population prior to study initiation. In addition, visual classification by a trained individual was confirmed based on assessment of the analytical variability between replicates. Finally, self-sampling at home was overall (very) positively received by the participants.

Abstract Image

青少年在家自行采样:评估无经验者成功采集血液微量样本的可行性。
在过去的几十年里,血液微量采样作为一种更加以病人为中心的采样方法,吸引了越来越多的人关注,因为这种方法只需在家中刺破手指或手臂,就能采集到极少量的血液。除了传统的干血点(DBS)外,许多不同的自采血设备也已面世。显然,只有当(没有经验的)用户采集到高质量的样本时,才能确保家庭采样的成功。因此,我们评估了六种不同的微型采样设备对没有经验的青少年在家中采集毛细血管血液的可行性。参与者(n = 95)被随机分配在不同的时间点使用六种不同的自我采样装置中的四种(即 DBS、Mitra 体积吸收式微型采样器 (VAMS)、Capitainer B、Tasso M20、Minicollect 管和 Tasso+ 血清分离管 (SST))采集血液(干血或液血)。对样本的质量进行了目测和分析测定。此外,还通过调查问卷对参与者的满意度进行了评估。尽管大多数人都通过目测获得了成功,但不同设备的成功率却大相径庭。总体而言,Minicollect 管的成功率最低,尽管其他自采样装置也有改进的机会和必要。因此,这也强调了在研究开始前对目标人群采集的样本质量进行评估的重要性。此外,根据对重复样本之间分析差异的评估,由受过培训的人员进行的目视分类也得到了确认。最后,参与者对在家自行采样的总体评价(非常)积极。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
AAPS Journal
AAPS Journal 医学-药学
CiteScore
7.80
自引率
4.40%
发文量
109
审稿时长
1 months
期刊介绍: The AAPS Journal, an official journal of the American Association of Pharmaceutical Scientists (AAPS), publishes novel and significant findings in the various areas of pharmaceutical sciences impacting human and veterinary therapeutics, including: · Drug Design and Discovery · Pharmaceutical Biotechnology · Biopharmaceutics, Formulation, and Drug Delivery · Metabolism and Transport · Pharmacokinetics, Pharmacodynamics, and Pharmacometrics · Translational Research · Clinical Evaluations and Therapeutic Outcomes · Regulatory Science We invite submissions under the following article types: · Original Research Articles · Reviews and Mini-reviews · White Papers, Commentaries, and Editorials · Meeting Reports · Brief/Technical Reports and Rapid Communications · Regulatory Notes · Tutorials · Protocols in the Pharmaceutical Sciences In addition, The AAPS Journal publishes themes, organized by guest editors, which are focused on particular areas of current interest to our field.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信