In vitro evaluation of the impact of intraoral scanner, scanning aids, and the scanned arch on the scan accuracy of edentulous arches.

IF 3.4 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE
Faris Z Jamjoom, Adhwaa Aldghim, Omar Aldibasi, Burak Yilmaz
{"title":"In vitro evaluation of the impact of intraoral scanner, scanning aids, and the scanned arch on the scan accuracy of edentulous arches.","authors":"Faris Z Jamjoom, Adhwaa Aldghim, Omar Aldibasi, Burak Yilmaz","doi":"10.1111/jopr.13891","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To assess the accuracy of complete maxillary and mandibular edentulous arch scans obtained using two different intraoral scanners (IOSs), with and without scanning aids, and to compare these results to those obtained using conventional impression methods.</p><p><strong>Materials and methods: </strong>Two IOSs were used (TRIOS 4 [TRI] and Emerald S [EMR]) to scan maxillary and mandibular typodonts. The typodonts were scanned without scanning aids [TRI_WSA and EMR_WSA groups] (n = 10). The typodonts were then scanned under four scanning aid conditions (n = 10): composite markers [TRI_MRK and EMR_MRK groups], scanning spray [TRI_SPR and EMR_SPR groups], pressure indicating paste [TRI_PIP and EMR_PIP groups], and liquid-type scanning aid [TRI_LQD and EMR_LQD groups]. Conventional impressions of both arches were also made using irreversible hydrocolloids in stock trays [IHC] and using polyvinyl siloxane (PVS) impression material in custom trays (n = 10) which were digitized using a laboratory scanner. Using a metrology software program, all scans were compared to a reference scan in order to assess trueness and to each other to assess precision. Trueness and precision were expressed as the root mean square (RMS) of the absolute deviation values and the statistical analysis was modeled on a logarithmic scale using fixed-effects models to meet model assumptions (α = 0.05).</p><p><strong>Results: </strong>The main effect of arch (p = 0.004), scanner (p < 0.001), scanning aid (p = 0.041), and the interaction between scanner and scanning aid (p = 0.027) had a significant effect on mean RMS values of trueness. The arch (p = 0.015) and scanner (p < 0.001) had a significant effect on the mean RMS values of precision. The maxillary arch had better accuracy compared to the mandible. The TRIOS 4 scanner had better accuracy than both the Emerald S scanner and conventional impressions. The Emerald S had better precision than conventional impressions. The scanning spray and liquid-type scanning aids produced the best trueness with the TRIOS 4 scanner, while the liquid-type scanning aid and composite markers produced the best trueness for the Emerald S scanner.</p><p><strong>Conclusion: </strong>The scanned arch and the type of scanner had a significant effect on the accuracy of digital scans of completely edentulous arches. The scanning aid had a significant effect on the trueness of digital scans of completely edentulous arches which varied depending on the scanner used.</p>","PeriodicalId":49152,"journal":{"name":"Journal of Prosthodontics-Implant Esthetic and Reconstructive Dentistry","volume":null,"pages":null},"PeriodicalIF":3.4000,"publicationDate":"2024-07-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Prosthodontics-Implant Esthetic and Reconstructive Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/jopr.13891","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To assess the accuracy of complete maxillary and mandibular edentulous arch scans obtained using two different intraoral scanners (IOSs), with and without scanning aids, and to compare these results to those obtained using conventional impression methods.

Materials and methods: Two IOSs were used (TRIOS 4 [TRI] and Emerald S [EMR]) to scan maxillary and mandibular typodonts. The typodonts were scanned without scanning aids [TRI_WSA and EMR_WSA groups] (n = 10). The typodonts were then scanned under four scanning aid conditions (n = 10): composite markers [TRI_MRK and EMR_MRK groups], scanning spray [TRI_SPR and EMR_SPR groups], pressure indicating paste [TRI_PIP and EMR_PIP groups], and liquid-type scanning aid [TRI_LQD and EMR_LQD groups]. Conventional impressions of both arches were also made using irreversible hydrocolloids in stock trays [IHC] and using polyvinyl siloxane (PVS) impression material in custom trays (n = 10) which were digitized using a laboratory scanner. Using a metrology software program, all scans were compared to a reference scan in order to assess trueness and to each other to assess precision. Trueness and precision were expressed as the root mean square (RMS) of the absolute deviation values and the statistical analysis was modeled on a logarithmic scale using fixed-effects models to meet model assumptions (α = 0.05).

Results: The main effect of arch (p = 0.004), scanner (p < 0.001), scanning aid (p = 0.041), and the interaction between scanner and scanning aid (p = 0.027) had a significant effect on mean RMS values of trueness. The arch (p = 0.015) and scanner (p < 0.001) had a significant effect on the mean RMS values of precision. The maxillary arch had better accuracy compared to the mandible. The TRIOS 4 scanner had better accuracy than both the Emerald S scanner and conventional impressions. The Emerald S had better precision than conventional impressions. The scanning spray and liquid-type scanning aids produced the best trueness with the TRIOS 4 scanner, while the liquid-type scanning aid and composite markers produced the best trueness for the Emerald S scanner.

Conclusion: The scanned arch and the type of scanner had a significant effect on the accuracy of digital scans of completely edentulous arches. The scanning aid had a significant effect on the trueness of digital scans of completely edentulous arches which varied depending on the scanner used.

体外评估口内扫描仪、扫描辅助工具和扫描牙弓对无牙颌牙弓扫描精度的影响。
目的:评估使用两种不同的口内扫描仪(IOS)在使用和不使用扫描辅助工具的情况下获得的完整上颌和下颌无牙弓扫描结果的准确性,并将这些结果与使用传统印模方法获得的结果进行比较:使用两台口内扫描仪(TRIOS 4 [TRI]和 Emerald S [EMR])扫描上颌和下颌排牙。在没有扫描辅助工具的情况下对排牙进行扫描[TRI_WSA 组和 EMR_WSA 组](n = 10)。然后在四种扫描辅助条件下扫描排牙(n = 10):复合标记[TRI_MRK 和 EMR_MRK 组]、扫描喷雾[TRI_SPR 和 EMR_SPR 组]、压力指示膏[TRI_PIP 和 EMR_PIP 组]以及液体型扫描辅助[TRI_LQD 和 EMR_LQD 组]。此外,还使用不可逆水胶体在库存托盘[IHC]中制作了两个牙弓的传统印模,并使用聚乙烯硅氧烷(PVS)印模材料在定制托盘(n = 10)中制作了两个牙弓的传统印模,并使用实验室扫描仪对这些印模进行了数字化处理。使用计量软件程序将所有扫描结果与参考扫描结果进行比较,以评估真实度,并相互比较以评估精确度。真实度和精确度以绝对偏差值的均方根(RMS)表示,统计分析采用对数刻度,使用固定效应模型,以满足模型假设(α = 0.05):拱形(p = 0.004)、扫描仪(p < 0.001)、扫描辅助工具(p = 0.041)的主效应以及扫描仪和扫描辅助工具之间的交互作用(p = 0.027)对真实度的平均有效值有显著影响。牙弓(p = 0.015)和扫描仪(p < 0.001)对精确度的平均有效值有显著影响。与下颌相比,上颌牙弓的精确度更高。TRIOS 4扫描仪的精确度高于Emerald S扫描仪和传统印模。Emerald S扫描仪的精确度高于传统印模。TRIOS 4扫描仪的扫描喷雾和液体型扫描辅助工具产生的真实度最好,而Emerald S扫描仪的液体型扫描辅助工具和复合标记产生的真实度最好:结论:扫描的牙弓和扫描仪类型对完全无牙颌牙弓数字扫描的准确性有显著影响。扫描辅助工具对全口无牙颌牙弓数字化扫描的真实度有显著影响,而真实度因所使用的扫描仪而异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
7.90
自引率
15.00%
发文量
171
审稿时长
6-12 weeks
期刊介绍: The Journal of Prosthodontics promotes the advanced study and practice of prosthodontics, implant, esthetic, and reconstructive dentistry. It is the official journal of the American College of Prosthodontists, the American Dental Association-recognized voice of the Specialty of Prosthodontics. The journal publishes evidence-based original scientific articles presenting information that is relevant and useful to prosthodontists. Additionally, it publishes reports of innovative techniques, new instructional methodologies, and instructive clinical reports with an interdisciplinary flair. The journal is particularly focused on promoting the study and use of cutting-edge technology and positioning prosthodontists as the early-adopters of new technology in the dental community.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信