Dynamic parameters of fluid responsiveness in the operating room : An analysis of intraoperative ventilation framework conditions.

Die Anaesthesiologie Pub Date : 2024-07-01 Epub Date: 2024-06-28 DOI:10.1007/s00101-024-01428-y
M Prütz, A Bozkurt, B Löser, S A Haas, D Tschopp, P Rieder, S Trachsel, G Vorderwülbecke, M Menk, F Balzer, S Treskatsch, D A Reuter, A Zitzmann
{"title":"Dynamic parameters of fluid responsiveness in the operating room : An analysis of intraoperative ventilation framework conditions.","authors":"M Prütz, A Bozkurt, B Löser, S A Haas, D Tschopp, P Rieder, S Trachsel, G Vorderwülbecke, M Menk, F Balzer, S Treskatsch, D A Reuter, A Zitzmann","doi":"10.1007/s00101-024-01428-y","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Reliable assessment of fluid responsiveness with pulse pressure variation (PPV) depends on certain ventilation-related preconditions; however, some of these requirements are in contrast with recommendations for protective ventilation.</p><p><strong>Objective: </strong>The aim of this study was to evaluate the applicability of PPV in patients undergoing non-cardiac surgery by retrospectively analyzing intraoperative ventilation data.</p><p><strong>Material and methods: </strong>Intraoperative ventilation data from three large medical centers in Germany and Switzerland from January to December 2018 were extracted from electronic patient records and pseudonymized; 10,334 complete data sets were analyzed with respect to the ventilation parameters set as well as demographic and medical data.</p><p><strong>Results: </strong>In 6.3% of the 3398 included anesthesia records, patients were ventilated with mean tidal volumes (mTV) > 8 ml/kg predicted body weight (PBW). These would qualify for PPV-based hemodynamic assessment, but the majority were ventilated with lower mTVs. In patients who underwent abdominal surgery (75.5% of analyzed cases), mTVs > 8 ml/kg PBW were used in 5.5% of cases, which did not differ between laparoscopic (44.9%) and open (55.1%) approaches. Other obstacles to the use of PPV, such as elevated positive end-expiratory pressure (PEEP) or increased respiratory rate, were also identified. Of all the cases 6.0% were ventilated with a mTV of > 8 ml/kg PBW and a PEEP of 5-10 cmH<sub>2</sub>O and 0.3% were ventilated with a mTV > 8 ml/kg PBW and a PEEP of > 10 cmH<sub>2</sub>O.</p><p><strong>Conclusion: </strong>The data suggest that only few patients meet the currently defined TV (of > 8 ml/kg PBW) for assessment of fluid responsiveness using PPV during surgery.</p>","PeriodicalId":72805,"journal":{"name":"Die Anaesthesiologie","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11222210/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Die Anaesthesiologie","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s00101-024-01428-y","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/28 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Reliable assessment of fluid responsiveness with pulse pressure variation (PPV) depends on certain ventilation-related preconditions; however, some of these requirements are in contrast with recommendations for protective ventilation.

Objective: The aim of this study was to evaluate the applicability of PPV in patients undergoing non-cardiac surgery by retrospectively analyzing intraoperative ventilation data.

Material and methods: Intraoperative ventilation data from three large medical centers in Germany and Switzerland from January to December 2018 were extracted from electronic patient records and pseudonymized; 10,334 complete data sets were analyzed with respect to the ventilation parameters set as well as demographic and medical data.

Results: In 6.3% of the 3398 included anesthesia records, patients were ventilated with mean tidal volumes (mTV) > 8 ml/kg predicted body weight (PBW). These would qualify for PPV-based hemodynamic assessment, but the majority were ventilated with lower mTVs. In patients who underwent abdominal surgery (75.5% of analyzed cases), mTVs > 8 ml/kg PBW were used in 5.5% of cases, which did not differ between laparoscopic (44.9%) and open (55.1%) approaches. Other obstacles to the use of PPV, such as elevated positive end-expiratory pressure (PEEP) or increased respiratory rate, were also identified. Of all the cases 6.0% were ventilated with a mTV of > 8 ml/kg PBW and a PEEP of 5-10 cmH2O and 0.3% were ventilated with a mTV > 8 ml/kg PBW and a PEEP of > 10 cmH2O.

Conclusion: The data suggest that only few patients meet the currently defined TV (of > 8 ml/kg PBW) for assessment of fluid responsiveness using PPV during surgery.

手术室液体反应的动态参数:术中通气框架条件分析。
背景:利用脉压变异(PPV)对液体反应性进行可靠评估取决于某些与通气相关的先决条件;然而,其中一些要求与保护性通气的建议相悖:本研究旨在通过回顾性分析术中通气数据,评估 PPV 在非心脏手术患者中的适用性:从电子病历中提取了德国和瑞士三家大型医疗中心2018年1月至12月的术中通气数据,并进行了化名处理;分析了10334个完整数据集的通气参数设置以及人口统计学和医学数据:在纳入的 3398 份麻醉记录中,有 6.3% 的患者通气时平均潮气量 (mTV) > 8 毫升/千克预测体重 (PBW)。这些患者有资格进行基于 PPV 的血液动力学评估,但大多数患者的通气潮气量较低。在接受腹部手术的患者中(占分析病例的 75.5%),5.5% 的病例使用的 mTV > 8 毫升/千克预测体重(PBW),腹腔镜手术(44.9%)和开腹手术(55.1%)之间没有差异。还发现了使用 PPV 的其他障碍,如呼气末正压(PEEP)升高或呼吸频率增加。在所有病例中,6.0%的患者在 mTV > 8 ml/kg PBW 和 PEEP 5-10 cmH2O 的情况下通气,0.3%的患者在 mTV > 8 ml/kg PBW 和 PEEP > 10 cmH2O 的情况下通气:数据表明,只有极少数患者符合目前规定的 TV(> 8 毫升/千克 PBW),可在手术期间使用 PPV 评估液体反应性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信