Christopher N Carender, Dirk R Larson, Robert T Trousdale, David G Lewallen, Daniel J Berry, Matthew P Abdel
{"title":"Aseptic Revision Total Hip Arthroplasty Using Modular Fluted Tapered Stems: Long-Term Follow-up of 515 Cases.","authors":"Christopher N Carender, Dirk R Larson, Robert T Trousdale, David G Lewallen, Daniel J Berry, Matthew P Abdel","doi":"10.2106/JBJS.23.00921","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Modular fluted tapered (MFT) femoral components are frequently utilized in aseptic revision total hip arthroplasties (THAs). However, long-term follow-up has been limited. The purpose of this study was to update our prior series at long-term follow-up, with specific emphasis on implant survivorship, radiographic results, and complications in a large cohort of aseptic revision THAs using MFT stems.</p><p><strong>Methods: </strong>We retrospectively identified 515 aseptic femoral revisions performed with 2 MFT stem designs in the total joint registry of a single tertiary care academic institution from 1999 to 2013. Serial radiographs were reviewed for subsidence of >5 mm. The mean follow-up (and standard deviation) was 10 ± 5 years (range, 2 to 21 years). A competing risk model accounting for death was utilized.</p><p><strong>Results: </strong>The 15-year cumulative incidence of any revision was 12%. There were 57 revisions, 27 of which involved revision of the fluted tapered component (FTC). Dislocation (n = 19), periprosthetic joint infection (n = 15), and aseptic loosening of the FTC (n = 11) were the most common reasons for revision. The 15-year cumulative incidence of any reoperation was 16%. The 15-year cumulative incidences were 6% for any FTC revision and 2% for FTC revision for aseptic loosening. Stem subsidence of >5 mm occurred in 2% of unrevised cases, and all but 1 stem was stable at the most recent follow-up.</p><p><strong>Conclusions: </strong>This large series of MFT stems used in aseptic revision THAs had a 2% incidence of subsequent revision of the FTC for aseptic loosening at 15 years. Dislocation and infection were the most common reasons for any revision.</p><p><strong>Level of evidence: </strong>Therapeutic Level III . See Instructions for Authors for a complete description of levels of evidence.</p>","PeriodicalId":15273,"journal":{"name":"Journal of Bone and Joint Surgery, American Volume","volume":" ","pages":"1470-1478"},"PeriodicalIF":4.4000,"publicationDate":"2024-08-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Bone and Joint Surgery, American Volume","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2106/JBJS.23.00921","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/28 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Modular fluted tapered (MFT) femoral components are frequently utilized in aseptic revision total hip arthroplasties (THAs). However, long-term follow-up has been limited. The purpose of this study was to update our prior series at long-term follow-up, with specific emphasis on implant survivorship, radiographic results, and complications in a large cohort of aseptic revision THAs using MFT stems.
Methods: We retrospectively identified 515 aseptic femoral revisions performed with 2 MFT stem designs in the total joint registry of a single tertiary care academic institution from 1999 to 2013. Serial radiographs were reviewed for subsidence of >5 mm. The mean follow-up (and standard deviation) was 10 ± 5 years (range, 2 to 21 years). A competing risk model accounting for death was utilized.
Results: The 15-year cumulative incidence of any revision was 12%. There were 57 revisions, 27 of which involved revision of the fluted tapered component (FTC). Dislocation (n = 19), periprosthetic joint infection (n = 15), and aseptic loosening of the FTC (n = 11) were the most common reasons for revision. The 15-year cumulative incidence of any reoperation was 16%. The 15-year cumulative incidences were 6% for any FTC revision and 2% for FTC revision for aseptic loosening. Stem subsidence of >5 mm occurred in 2% of unrevised cases, and all but 1 stem was stable at the most recent follow-up.
Conclusions: This large series of MFT stems used in aseptic revision THAs had a 2% incidence of subsequent revision of the FTC for aseptic loosening at 15 years. Dislocation and infection were the most common reasons for any revision.
Level of evidence: Therapeutic Level III . See Instructions for Authors for a complete description of levels of evidence.
期刊介绍:
The Journal of Bone & Joint Surgery (JBJS) has been the most valued source of information for orthopaedic surgeons and researchers for over 125 years and is the gold standard in peer-reviewed scientific information in the field. A core journal and essential reading for general as well as specialist orthopaedic surgeons worldwide, The Journal publishes evidence-based research to enhance the quality of care for orthopaedic patients. Standards of excellence and high quality are maintained in everything we do, from the science of the content published to the customer service we provide. JBJS is an independent, non-profit journal.