Long-Term Results of Physician-Modified Endografts for the Treatment of Elective, Symptomatic, and Ruptured Juxtarenal Abdominal Aortic Aneurysms.

IF 7.5 1区 医学 Q1 SURGERY
Annals of surgery Pub Date : 2024-10-01 Epub Date: 2024-06-26 DOI:10.1097/SLA.0000000000006422
Benjamin W Starnes, Sara Zettervall, Allison Larimore, Niten Singh
{"title":"Long-Term Results of Physician-Modified Endografts for the Treatment of Elective, Symptomatic, and Ruptured Juxtarenal Abdominal Aortic Aneurysms.","authors":"Benjamin W Starnes, Sara Zettervall, Allison Larimore, Niten Singh","doi":"10.1097/SLA.0000000000006422","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>The objective of this study was to report long-term results of an ongoing physician-sponsored, investigational device exemption (IDE) pivotal clinical trial using physician-modified endovascular grafts (PMEGs) for the treatment of patients with juxtarenal aortic aneurysms.</p><p><strong>Methods: </strong>Data from a nonrandomized, prospective, consecutively enrolling IDE clinical trial were used. Data collection began on April 1, 2011, and data lock occurred on January 2, 2024, with outcomes analysis through December 31, 2023. Primary safety and effectiveness end points were used to measure treatment success. The safety end point was defined as the proportion of subjects who experienced a major adverse event within 30 days of the procedure. The effectiveness end point was the proportion of subjects who achieved treatment success. Treatment success required the following at 12 months: technical success, defined as successful delivery and deployment of a PMEG with preservation of intended branch vessels; and freedom from: type I and III endoleak, stent graft migration >10 mm, aortic aneurysm sack enlargement >5 mm, and aortic aneurysm rupture or open conversion.</p><p><strong>Results: </strong>Over the 12-year study period, 228 patients were enrolled; 205 began the implant procedure, and 203 received PMEG. Thirteen patients withdrew prior to PMEG. Two withdrew (<1.0%) after failure to deploy due to tortuous iliac anatomy and are tracked as intent to treat, and a total of 24 withdrew after receiving the PMEG implant. Forty-four patients died during the study period. A total of 14 were deemed lost to follow-up. Fifty-nine completed the 5-year follow-up period, and 62 remain active in follow-up visits.Aneurysm anatomy, operative details, and lengths of stay were recorded and included: aneurysm diameter (mean, 67.5 mm; range, 49-124 mm), proximal seal zone length (mean, 41.6 mm; range, 18.9-92.9 mm), graft modification time (mean, 48.7 min), procedure time (mean, 137.7 min), fluoroscopy time (mean, 33.8 min), contrast material use (mean, 93.0 mL), estimated blood loss (mean, 118.8 mL), length of hospital stay (mean, 3.7 d), and intensive care unit length of stay (mean, 1.6 d).A total of 575 fenestrations were created for 387 renal arteries, 181 superior mesenteric arteries (SMAs), and 7 celiac arteries. Renal arteries were in 96% of patients and included 410 renal artery stents in 203 patients. The SMA was stented as needed and included one patient with an SMA stent placed before the procedure, 19 during the procedure, and 2 patients who underwent stent placement after the procedure. There were no open conversions or device migrations and 1 partial explant due to late distal graft occlusion. Three ruptures (1.4%) were recorded on days 830, 1346, and 1460. There was 1 presumed graft infection at 750 days (<0.5%) treated with? Thirty-day all-cause mortality was 2.9% (6/204). One type Ia, 1 type Ib, and 7 type III endoleaks were identified during follow-up and treated with successful reintervention at the 1-year period. The overall rate of major adverse events at 30 days was 15% (29/194). Technical success was 93.7%, and overall treatment success was 82.6%.</p><p><strong>Conclusions: </strong>PMEG can be performed with low rates of long-term morbidity and mortality, confirming our early and midterm reports that endovascular repair with PMEG is safe, durable, and effective for managing patients with juxtarenal aortic aneurysms. While historically considered experimental, these results suggest that PMEG is a safe and durable option and should be considered for patients where off-the-shelf devices are not available.</p>","PeriodicalId":8017,"journal":{"name":"Annals of surgery","volume":null,"pages":null},"PeriodicalIF":7.5000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11379358/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/SLA.0000000000006422","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/26 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: The objective of this study was to report long-term results of an ongoing physician-sponsored, investigational device exemption (IDE) pivotal clinical trial using physician-modified endovascular grafts (PMEGs) for the treatment of patients with juxtarenal aortic aneurysms.

Methods: Data from a nonrandomized, prospective, consecutively enrolling IDE clinical trial were used. Data collection began on April 1, 2011, and data lock occurred on January 2, 2024, with outcomes analysis through December 31, 2023. Primary safety and effectiveness end points were used to measure treatment success. The safety end point was defined as the proportion of subjects who experienced a major adverse event within 30 days of the procedure. The effectiveness end point was the proportion of subjects who achieved treatment success. Treatment success required the following at 12 months: technical success, defined as successful delivery and deployment of a PMEG with preservation of intended branch vessels; and freedom from: type I and III endoleak, stent graft migration >10 mm, aortic aneurysm sack enlargement >5 mm, and aortic aneurysm rupture or open conversion.

Results: Over the 12-year study period, 228 patients were enrolled; 205 began the implant procedure, and 203 received PMEG. Thirteen patients withdrew prior to PMEG. Two withdrew (<1.0%) after failure to deploy due to tortuous iliac anatomy and are tracked as intent to treat, and a total of 24 withdrew after receiving the PMEG implant. Forty-four patients died during the study period. A total of 14 were deemed lost to follow-up. Fifty-nine completed the 5-year follow-up period, and 62 remain active in follow-up visits.Aneurysm anatomy, operative details, and lengths of stay were recorded and included: aneurysm diameter (mean, 67.5 mm; range, 49-124 mm), proximal seal zone length (mean, 41.6 mm; range, 18.9-92.9 mm), graft modification time (mean, 48.7 min), procedure time (mean, 137.7 min), fluoroscopy time (mean, 33.8 min), contrast material use (mean, 93.0 mL), estimated blood loss (mean, 118.8 mL), length of hospital stay (mean, 3.7 d), and intensive care unit length of stay (mean, 1.6 d).A total of 575 fenestrations were created for 387 renal arteries, 181 superior mesenteric arteries (SMAs), and 7 celiac arteries. Renal arteries were in 96% of patients and included 410 renal artery stents in 203 patients. The SMA was stented as needed and included one patient with an SMA stent placed before the procedure, 19 during the procedure, and 2 patients who underwent stent placement after the procedure. There were no open conversions or device migrations and 1 partial explant due to late distal graft occlusion. Three ruptures (1.4%) were recorded on days 830, 1346, and 1460. There was 1 presumed graft infection at 750 days (<0.5%) treated with? Thirty-day all-cause mortality was 2.9% (6/204). One type Ia, 1 type Ib, and 7 type III endoleaks were identified during follow-up and treated with successful reintervention at the 1-year period. The overall rate of major adverse events at 30 days was 15% (29/194). Technical success was 93.7%, and overall treatment success was 82.6%.

Conclusions: PMEG can be performed with low rates of long-term morbidity and mortality, confirming our early and midterm reports that endovascular repair with PMEG is safe, durable, and effective for managing patients with juxtarenal aortic aneurysms. While historically considered experimental, these results suggest that PMEG is a safe and durable option and should be considered for patients where off-the-shelf devices are not available.

医生改良内移植物治疗择期、有症状和破裂的腹主动脉瘤的长期效果。
研究目的本研究旨在报告一项由医生发起、正在进行的研究性设备豁免(IDE)关键临床试验的长期结果,该试验使用医生改良型血管内移植物(PMEGs)治疗并arenal主动脉瘤患者:采用了一项非随机、前瞻性、连续注册的 IDE 临床试验的数据。数据收集始于 2011 年 4 月 1 日,数据锁定于 2024 年 1 月 2 日,结果分析截至 2023 年 12 月 31 日。主要安全性和有效性终点用于衡量治疗成功与否。安全性终点的定义是在手术后 30 天内发生重大不良事件的受试者比例。有效性终点是获得治疗成功的受试者比例。治疗成功要求在 12 个月内达到以下标准:技术成功,即成功输送和部署 PMEG 并保留预定分支血管;无 I 型和 III 型内漏、支架移植物移位 >10 毫米、主动脉瘤袋扩大 >5 毫米、主动脉瘤破裂或开放性转换:在长达 12 年的研究期间,共有 228 名患者入选;其中 205 人开始了植入手术,203 人接受了 PMEG。13 名患者在接受 PMEG 之前退出。两名患者退出(结论:PMEG 手术的长期发病率和死亡率都很低,证实了我们的早期和中期报告,即使用 PMEG 进行血管内修复对于治疗并arenal 主动脉瘤患者是安全、持久和有效的。虽然 PMEG 一直被认为是实验性的,但这些结果表明,PMEG 是一种安全、耐用的选择,对于没有现成设备的患者,应该考虑使用 PMEG。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Annals of surgery
Annals of surgery 医学-外科
CiteScore
14.40
自引率
4.40%
发文量
687
审稿时长
4 months
期刊介绍: The Annals of Surgery is a renowned surgery journal, recognized globally for its extensive scholarly references. It serves as a valuable resource for the international medical community by disseminating knowledge regarding important developments in surgical science and practice. Surgeons regularly turn to the Annals of Surgery to stay updated on innovative practices and techniques. The journal also offers special editorial features such as "Advances in Surgical Technique," offering timely coverage of ongoing clinical issues. Additionally, the journal publishes monthly review articles that address the latest concerns in surgical practice.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信