Noninvasive bipolar radiofrequency - vaginal application on swine model

Q4 Medicine
P. Kolczewski, M. Barwijuk, M. Parafiniuk, A. Kolasa, J. Udała, D. Gączarzewicz, M. Łukaszuk, N. Zerbinati, R. Kuźlik, A. Kordek, D. Branecka-Woźniak, M. Kozłowski, A. Cymbaluk-Płoska
{"title":"Noninvasive bipolar radiofrequency - vaginal application on swine model","authors":"P. Kolczewski, M. Barwijuk, M. Parafiniuk, A. Kolasa, J. Udała, D. Gączarzewicz, M. Łukaszuk, N. Zerbinati, R. Kuźlik, A. Kordek, D. Branecka-Woźniak, M. Kozłowski, A. Cymbaluk-Płoska","doi":"10.56609/jac.v42i1.340","DOIUrl":null,"url":null,"abstract":"The aim of the study was to evaluate the concentration of collagen and elastin fibers, the number of fibroblasts/fibrocytes and vessels, as well as depth of action in the vaginal wall in a swine model before and after intravaginal 480 kHz bipolar radiofrequency heating created by a 360-degree intravaginal applicator (Berger and Kraft Medical). Three swine’s were treated with a bipolar radiofrequency vaginal probe. Exposure to RF was administered twice, every 4 weeks, and then the vaginas were removed after slaughter, four weeks after the last RF exposure. Histology specimens were obtained from control and exposed areas. Tissue samples were stained by hematoxylin-eosin, orcein, and Mallory trichrome. The concentration of elastin and collagen fibers increased distinctly after a treatment protocol: elastin, on average, was 52.8%, and collagen, on average, was 103.6%. After the treatment protocol, we revealed a significant dispersion of fibroblasts-fibrocytes nuclei for particular animals in segmented areas, with a slightly marked falling trend. A degree of data variability cannot lead to a conclusion concerning the influence of RF heating on several vessels in evaluated areas. The depth of action of the RF heating, measured by collagen concentration, reached up to 1.3 mm of the vaginal wall thickness. Results imply that heating of the vaginal wall, created by radiofrequency, induces neocollagenogenesis and neoelastogenesis, leading to a distinctive rise of collagen and elastin fibers concentration at a depth of up to 1.3 mm of the thickness of the vaginal wall in the animal model.","PeriodicalId":15008,"journal":{"name":"Journal of applied cosmetology","volume":"3 3","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-06-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of applied cosmetology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.56609/jac.v42i1.340","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

The aim of the study was to evaluate the concentration of collagen and elastin fibers, the number of fibroblasts/fibrocytes and vessels, as well as depth of action in the vaginal wall in a swine model before and after intravaginal 480 kHz bipolar radiofrequency heating created by a 360-degree intravaginal applicator (Berger and Kraft Medical). Three swine’s were treated with a bipolar radiofrequency vaginal probe. Exposure to RF was administered twice, every 4 weeks, and then the vaginas were removed after slaughter, four weeks after the last RF exposure. Histology specimens were obtained from control and exposed areas. Tissue samples were stained by hematoxylin-eosin, orcein, and Mallory trichrome. The concentration of elastin and collagen fibers increased distinctly after a treatment protocol: elastin, on average, was 52.8%, and collagen, on average, was 103.6%. After the treatment protocol, we revealed a significant dispersion of fibroblasts-fibrocytes nuclei for particular animals in segmented areas, with a slightly marked falling trend. A degree of data variability cannot lead to a conclusion concerning the influence of RF heating on several vessels in evaluated areas. The depth of action of the RF heating, measured by collagen concentration, reached up to 1.3 mm of the vaginal wall thickness. Results imply that heating of the vaginal wall, created by radiofrequency, induces neocollagenogenesis and neoelastogenesis, leading to a distinctive rise of collagen and elastin fibers concentration at a depth of up to 1.3 mm of the thickness of the vaginal wall in the animal model.
无创双极射频--在猪模型上的阴道应用
这项研究的目的是评估猪阴道模型中胶原蛋白和弹性纤维的浓度、成纤维细胞/纤维细胞和血管的数量,以及阴道壁在使用 360 度阴道内涂抹器(Berger 和 Kraft Medical 公司生产)进行阴道内 480 kHz 双极射频加热前后的作用深度。三头猪接受了双极射频阴道探头的治疗。射频照射每 4 周进行两次,然后在最后一次射频照射 4 周后屠宰并切除阴道。从对照区和暴露区获取组织学标本。组织样本用苏木精-伊红、橙皮苷和马洛里三色染色。治疗方案后,弹性蛋白和胶原纤维的浓度明显增加:弹性蛋白平均为 52.8%,胶原蛋白平均为 103.6%。治疗方案结束后,我们发现在分割区域的特定动物中,成纤维细胞-纤维细胞核明显分散,并略有明显的下降趋势。由于数据存在一定程度的差异,因此无法就射频加热对评估区域内若干血管的影响得出结论。根据胶原蛋白浓度测量,射频加热的作用深度可达阴道壁厚度的 1.3 毫米。研究结果表明,射频加热阴道壁可诱导新胶原生成和新弹性生成,导致胶原蛋白和弹性纤维浓度明显增加,其深度可达动物模型阴道壁厚度的 1.3 毫米。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of applied cosmetology
Journal of applied cosmetology Medicine-Dermatology
CiteScore
0.40
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信