Effect of Apical Preparation on Different Needle Depth Penetration.

Samara Gurgis Essa, R. K. Saeed, Diyar Khalid Baker
{"title":"Effect of Apical Preparation on Different Needle Depth Penetration.","authors":"Samara Gurgis Essa, R. K. Saeed, Diyar Khalid Baker","doi":"10.15218/edj.2024.7","DOIUrl":null,"url":null,"abstract":"Introduction: Irrigation is a fundamental part of endodontic debridement as because it allows for cleaning beyond what might be accomplished by root canal instrumentation. The flushing action produced by the irrigant and the penetration of the irrigant is not dependent only on the anatomy of the root canal system, but also on the depth of placement, system of delivery, the volume and fluid properties of the irrigant. Aim: The aim of the study was to evaluate the effect of apical preparation on the penetration depth of different types of needles. Methods: Thirty single-rooted lower premolar teeth were involved in this study. The access opening was performed by using a round diamond bur turbine (diameter 12) and Kfiles (diameter 15) were used for initial penetration in the canal. Stereo- microscope under 20 magnifications was used to determine the working length of the canal. Then the canals were prepared using protaper next in continuos rotation according to manufacture instructions with sequence files reached the WL (X1, X2, X3, X4). 4 mL of 5.25% NaOCI was used between each instrument. Three different types of endodontic needles were used. Needles size 27, 30-gauge stainless steel and IRRIFLEX endodontic irrigation needle. Each needle was inserted in the canal and its length of penetration was measured before canal preparation and after finishing files then the depth of penetration was measured. Results: ANOVA test showed that there are significant differences among all groups also results show a significant difference when comparing 27 with 30 needle gauge irriflex but there was no significant difference between the needle gauge 30 and irriflex. Conclusion: This study shows that the penetration depth of needles influences on apical preparation it appears that 27 -gauge needles show less depth penetration when compared to irriflex and 30- gauge needles. Keywords: apical, needle, penetration depth, endodontics.","PeriodicalId":257297,"journal":{"name":"Erbil Dental Journal","volume":"17 9","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-06-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Erbil Dental Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15218/edj.2024.7","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Irrigation is a fundamental part of endodontic debridement as because it allows for cleaning beyond what might be accomplished by root canal instrumentation. The flushing action produced by the irrigant and the penetration of the irrigant is not dependent only on the anatomy of the root canal system, but also on the depth of placement, system of delivery, the volume and fluid properties of the irrigant. Aim: The aim of the study was to evaluate the effect of apical preparation on the penetration depth of different types of needles. Methods: Thirty single-rooted lower premolar teeth were involved in this study. The access opening was performed by using a round diamond bur turbine (diameter 12) and Kfiles (diameter 15) were used for initial penetration in the canal. Stereo- microscope under 20 magnifications was used to determine the working length of the canal. Then the canals were prepared using protaper next in continuos rotation according to manufacture instructions with sequence files reached the WL (X1, X2, X3, X4). 4 mL of 5.25% NaOCI was used between each instrument. Three different types of endodontic needles were used. Needles size 27, 30-gauge stainless steel and IRRIFLEX endodontic irrigation needle. Each needle was inserted in the canal and its length of penetration was measured before canal preparation and after finishing files then the depth of penetration was measured. Results: ANOVA test showed that there are significant differences among all groups also results show a significant difference when comparing 27 with 30 needle gauge irriflex but there was no significant difference between the needle gauge 30 and irriflex. Conclusion: This study shows that the penetration depth of needles influences on apical preparation it appears that 27 -gauge needles show less depth penetration when compared to irriflex and 30- gauge needles. Keywords: apical, needle, penetration depth, endodontics.
根尖准备对不同针刺深度的影响
导言:冲洗是根管清创的一个基本组成部分,因为它可以使根管器械无法达到的清洁效果得以实现。冲洗剂产生的冲洗作用和冲洗剂的渗透不仅取决于根管系统的解剖结构,还取决于根管的置入深度、输送系统、冲洗剂的容量和液体特性。目的:本研究旨在评估根尖预备对不同类型针头渗透深度的影响。方法:对 30 颗单根下前臼齿进行根尖预备:研究对象为 30 颗单根下前磨牙。使用圆形金刚石毛刺涡轮机(直径 12)打开通路,并使用 Kfiles(直径 15)初步穿透牙管。使用 20 倍放大镜下的立体显微镜确定牙管的工作长度。然后,根据生产说明,使用连续旋转的下一个原牙器制备根管,顺序文件达到 WL(X1、X2、X3、X4)。每个器械之间使用 4 毫升 5.25% NaOCI。使用了三种不同类型的根管针。27 号针、30 号不锈钢针和 IRRIFLEX 根管冲洗针。将每种针插入牙管,在牙管预备前测量其穿透长度,在完成锉磨后测量穿透深度。结果方差分析测试表明,各组之间存在显著差异,27 号针头和 30 号irriflex 相比也存在显著差异,但 30 号针头和irriflex 之间没有显著差异。结论这项研究表明,针的穿刺深度对根尖预备有影响,与irriflex和30号针相比,27号针的穿刺深度较小。关键词:根尖、针、穿透深度、根管治疗。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信