SPATIAL RESOLUTION IMPROVEMENT OF THE NUCLEAR SCANNING MICROPROBE CHANNEL OF THE ANALYTICAL ACCELERATOR COMPLEX OF THE API NAS OF UKRAINE

A.G. Ponomarev, V.I. Vozny, I.H. Ihnatiev, S. Kolinko, D. V. Magilin, V. Rebrov
{"title":"SPATIAL RESOLUTION IMPROVEMENT OF THE NUCLEAR SCANNING MICROPROBE CHANNEL OF THE ANALYTICAL ACCELERATOR COMPLEX OF THE API NAS OF UKRAINE","authors":"A.G. Ponomarev, V.I. Vozny, I.H. Ihnatiev, S. Kolinko, D. V. Magilin, V. Rebrov","doi":"10.46813/2024-151-087","DOIUrl":null,"url":null,"abstract":"The probe-forming system of a nuclear scanning microprobe based on a quadruplet of magnetic quadrupole lenses with three independent power supplies has been studied. In the stigmatic focusing mode, the third power supply is a free parameter affecting the ion-optical properties of the microprobe. The optimal system was selected as\na result of solving an optimization problem in which the figure of merit was the reduced collimated acceptance. The numerical simulation of the beam focusing process in that one-parametric system, taking into account the experimentally measured distribution of protons in the trajectory phase space, showed that the dimensions of the beam\nspot on the target can be reduced several times compared to the working system. At the same time, the current density in the focused spot increases by about one order.","PeriodicalId":510408,"journal":{"name":"Problems of Atomic Science and Technology","volume":" 939","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-06-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Problems of Atomic Science and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.46813/2024-151-087","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The probe-forming system of a nuclear scanning microprobe based on a quadruplet of magnetic quadrupole lenses with three independent power supplies has been studied. In the stigmatic focusing mode, the third power supply is a free parameter affecting the ion-optical properties of the microprobe. The optimal system was selected as a result of solving an optimization problem in which the figure of merit was the reduced collimated acceptance. The numerical simulation of the beam focusing process in that one-parametric system, taking into account the experimentally measured distribution of protons in the trajectory phase space, showed that the dimensions of the beam spot on the target can be reduced several times compared to the working system. At the same time, the current density in the focused spot increases by about one order.
提高乌克兰国家科学院分析加速器综合体核扫描微探针通道的空间分辨率
我们研究了核扫描微探针的探针形成系统,该系统基于带有三个独立电源的四极磁透镜。在柱状聚焦模式下,第三个电源是影响微探针离子光学特性的自由参数。最优系统是在解决优化问题后选出的,优化问题的优点是减少了准直接受度。考虑到实验所测得的质子在轨迹相空间中的分布情况,对该单参数系统中的光束聚焦过程进行了数值模拟,结果表明,与工作系统相比,靶上光束光斑的尺寸可缩小数倍。同时,聚焦光斑中的电流密度增加了约一个数量级。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书