{"title":"Comparison of Baska Mask Versus Endotracheal Tube for General Anesthesia in Laparoscopic Cholecystectomy: A Randomized Controlled Trial","authors":"Singaravelan Mariyappan, Anjana R, P. S, Naveena P, Sabapathy Appavoo V A, Arbind Kumar Choudhary","doi":"10.5812/jcma-145475","DOIUrl":null,"url":null,"abstract":": This study aimed to compare the Baska mask and the endotracheal tube, two devices used to manage patient airways during laparoscopic surgery. Fifty patients undergoing laparoscopic cholecystectomy were randomly assigned to receive either the Baska mask or the endotracheal tube. Data on patients’ demographic and physical status, as well as their heart rate, blood pressure, oxygen level, and ease of device insertion, were collected. The mean BMI for the Baska mask group was 24.68 kg/m² (± 4), and for the Endotracheal tube group, it was 24.83 kg/m² (± 4.14), showing no significant difference (P = 0.9768). However, significant differences were observed in hemodynamic parameters. Patients in the endotracheal tube group exhibited higher heart rates, blood pressure, and mean arterial pressure, indicating more cardiovascular stress than those in the Baska mask group. The endotracheal tube also caused more throat irritation, with more patients reporting post-surgery sore throat. The Baska mask was found to be easier and quicker to insert, requiring less skill and time. Both devices provided adequate oxygenation, but the endotracheal tube had more negative effects on the cardiovascular system and throat. In conclusion, the Baska mask could be a better alternative for laparoscopic surgery, improving both physiological parameters and patient comfort.","PeriodicalId":36599,"journal":{"name":"Journal of Cellular and Molecular Anesthesia","volume":"8 18","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-06-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Cellular and Molecular Anesthesia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5812/jcma-145475","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

: This study aimed to compare the Baska mask and the endotracheal tube, two devices used to manage patient airways during laparoscopic surgery. Fifty patients undergoing laparoscopic cholecystectomy were randomly assigned to receive either the Baska mask or the endotracheal tube. Data on patients’ demographic and physical status, as well as their heart rate, blood pressure, oxygen level, and ease of device insertion, were collected. The mean BMI for the Baska mask group was 24.68 kg/m² (± 4), and for the Endotracheal tube group, it was 24.83 kg/m² (± 4.14), showing no significant difference (P = 0.9768). However, significant differences were observed in hemodynamic parameters. Patients in the endotracheal tube group exhibited higher heart rates, blood pressure, and mean arterial pressure, indicating more cardiovascular stress than those in the Baska mask group. The endotracheal tube also caused more throat irritation, with more patients reporting post-surgery sore throat. The Baska mask was found to be easier and quicker to insert, requiring less skill and time. Both devices provided adequate oxygenation, but the endotracheal tube had more negative effects on the cardiovascular system and throat. In conclusion, the Baska mask could be a better alternative for laparoscopic surgery, improving both physiological parameters and patient comfort.
腹腔镜胆囊切除术中全身麻醉使用巴斯卡面罩与气管插管的比较:随机对照试验
:这项研究旨在比较巴斯卡喉罩和气管插管这两种在腹腔镜手术中用于管理患者气道的装置。50 名接受腹腔镜胆囊切除术的患者被随机分配到使用巴斯卡喉罩或气管插管。研究人员收集了患者的人口统计学、身体状况、心率、血压、血氧水平和装置插入难易程度等数据。巴斯卡喉罩组患者的平均体重指数为 24.68 kg/m²(± 4),气管导管组患者的平均体重指数为 24.83 kg/m²(± 4.14),两者无显著差异(P = 0.9768)。不过,在血液动力学参数方面观察到了明显的差异。气管插管组患者的心率、血压和平均动脉压均高于巴斯卡面罩组患者,表明心血管压力更大。气管插管对咽喉的刺激也更大,有更多患者报告术后咽喉疼痛。巴斯卡喉罩插入更容易、更快,所需的技能和时间更少。两种装置都能提供充足的氧气,但气管插管对心血管系统和喉咙的负面影响更大。总之,巴斯卡喉罩可能是腹腔镜手术的更好选择,既能改善生理参数,又能提高病人的舒适度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Cellular and Molecular Anesthesia
Journal of Cellular and Molecular Anesthesia Medicine-Anesthesiology and Pain Medicine
CiteScore
2.30
自引率
0.00%
发文量
0
审稿时长
6 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信