QUALIPAED—A retrospective quality control study evaluating pediatric long axial field-of-view low-dose FDG-PET/CT

Sabrina Honoré d’Este, F. L. Andersen, C. Schulze, E. Saxtoft, B. M. Fischer, K. F. Andersen
{"title":"QUALIPAED—A retrospective quality control study evaluating pediatric long axial field-of-view low-dose FDG-PET/CT","authors":"Sabrina Honoré d’Este, F. L. Andersen, C. Schulze, E. Saxtoft, B. M. Fischer, K. F. Andersen","doi":"10.3389/fnume.2024.1398773","DOIUrl":null,"url":null,"abstract":"Pediatric patients have an increased risk of radiation-induced malignancies due to their ongoing development and long remaining life span. Thus, optimization of PET protocols is an important task in pediatric nuclear medicine. Long axial field-of-view (LAFOV) PET/CT has shown a significant increase in sensitivity, which provides an ideal opportunity for reduction of injected tracer activity in the pediatric population. In this study we aim to evaluate the clinical performance of a 2-[18F]FDG-tracer reduction from 3 MBq/kg to 1.5 MBq/kg on the Biograph Vision Quadra LAFOV PET/CT.The first 50 pediatric patients referred for clinical whole-body PET/CT with 1.5 MBq/kg 2-[18F]FDG, were included. A standard pediatric protocol was applied. Five reconstructions were created with various time, filter and iteration settings. Image noise was computed as coefficient-of-variance (COV = SD/mean standardized-uptake-value) calculated from a spherical 20–50 mm (diameter) liver volume-of-interest. Sets of reconstructions were reviewed by one nuclear medicine physicians, who reported image lesions on a pre-defined list of sites. Paired comparison analysis was performed with significance at PB < 0.05 (Bonferroni corrected).All reconstructions, except one, achieved a COVmean (0.08–0.15) equal to or lower than current clinical acceptable values (COVref ≤ 0.15). Image noise significantly improved with increasing acquisition time, lowering iterations (i) from 6i to 4i (both with five subsets) and when applying a 2 mm Gauss filter (PB < 0.001). Significant difference in lesion detection was seen from 150s to 300s and from 150s to 600s (PB = 0.006–0.007). 99% of all lesions rated as malignant could be found on the 150s reconstruction, while 100% was found on the 300s, when compared to the 600s reconstruction.Injected activity and scan time can be reduced to 1.5 MBq/kg 2-[18F]FDG with 5 min acquisition time on LAFOV PET/CT, while maintaining clinical performance in the pediatric population. These results can help limit radiation exposure to patients and personnel as well as shorten total scan time, which can help increase patient comfort, lessen the need for sedation and provide individually tailored scans.","PeriodicalId":505895,"journal":{"name":"Frontiers in Nuclear Medicine","volume":"61 36","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-06-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Frontiers in Nuclear Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3389/fnume.2024.1398773","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Pediatric patients have an increased risk of radiation-induced malignancies due to their ongoing development and long remaining life span. Thus, optimization of PET protocols is an important task in pediatric nuclear medicine. Long axial field-of-view (LAFOV) PET/CT has shown a significant increase in sensitivity, which provides an ideal opportunity for reduction of injected tracer activity in the pediatric population. In this study we aim to evaluate the clinical performance of a 2-[18F]FDG-tracer reduction from 3 MBq/kg to 1.5 MBq/kg on the Biograph Vision Quadra LAFOV PET/CT.The first 50 pediatric patients referred for clinical whole-body PET/CT with 1.5 MBq/kg 2-[18F]FDG, were included. A standard pediatric protocol was applied. Five reconstructions were created with various time, filter and iteration settings. Image noise was computed as coefficient-of-variance (COV = SD/mean standardized-uptake-value) calculated from a spherical 20–50 mm (diameter) liver volume-of-interest. Sets of reconstructions were reviewed by one nuclear medicine physicians, who reported image lesions on a pre-defined list of sites. Paired comparison analysis was performed with significance at PB < 0.05 (Bonferroni corrected).All reconstructions, except one, achieved a COVmean (0.08–0.15) equal to or lower than current clinical acceptable values (COVref ≤ 0.15). Image noise significantly improved with increasing acquisition time, lowering iterations (i) from 6i to 4i (both with five subsets) and when applying a 2 mm Gauss filter (PB < 0.001). Significant difference in lesion detection was seen from 150s to 300s and from 150s to 600s (PB = 0.006–0.007). 99% of all lesions rated as malignant could be found on the 150s reconstruction, while 100% was found on the 300s, when compared to the 600s reconstruction.Injected activity and scan time can be reduced to 1.5 MBq/kg 2-[18F]FDG with 5 min acquisition time on LAFOV PET/CT, while maintaining clinical performance in the pediatric population. These results can help limit radiation exposure to patients and personnel as well as shorten total scan time, which can help increase patient comfort, lessen the need for sedation and provide individually tailored scans.
QUALIPAED--评估儿科长轴视场低剂量FDG-PET/CT的回顾性质量控制研究
小儿患者由于正在发育且剩余寿命较长,因此辐射诱发恶性肿瘤的风险较高。因此,优化 PET 方案是儿科核医学的一项重要任务。长轴视场(LAFOV)PET/CT 显示灵敏度显著提高,这为减少儿科患者的注射示踪剂活性提供了理想的机会。在本研究中,我们旨在评估在 Biograph Vision Quadra LAFOV PET/CT 上将 2-[18F]FDG 示踪剂从 3 MBq/kg 减少到 1.5 MBq/kg 的临床表现。采用标准儿科方案。以不同的时间、滤波器和迭代设置进行了五次重建。图像噪声以方差系数(COV = SD/平均标准化摄取值)计算,方差系数是根据20-50毫米(直径)的球形肝脏感兴趣体积计算得出的。一组重建图像由一名核医学医生审查,该医生报告预先确定的部位的图像病变。除一次外,所有重建的 COVmean(0.08-0.15)均等于或低于目前的临床可接受值(COVref ≤ 0.15)。随着采集时间的延长、迭代次数 (i) 从 6i 降至 4i(均为五个子集)以及应用 2 mm 高斯滤波器,图像噪声明显改善(PB < 0.001)。病变检测时间从 150 秒到 300 秒以及从 150 秒到 600 秒之间存在显著差异(PB = 0.006-0.007)。与 600s 重建相比,在 150s 重建中可发现 99% 的恶性病变,而在 300s 重建中则可发现 100% 的恶性病变。在 LAFOV PET/CT 上,注射活性和扫描时间可减少到 1.5 MBq/kg 2-[18F]FDG,采集时间为 5 分钟,同时还能保持儿科人群的临床表现。这些结果有助于限制对患者和工作人员的辐射照射,缩短总扫描时间,从而有助于提高患者的舒适度,减少镇静剂的需求,并提供量身定制的扫描。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信