{"title":"Intra-aortic balloon pump treatment in an adult patient with a Fontan circulation and acute heart failure: a case report","authors":"M. S. Langseth, N. Nordstrand, Gunnar Erikssen","doi":"10.1093/ehjcr/ytae289","DOIUrl":null,"url":null,"abstract":"\n \n \n There is limited evidence for the use of an intra-aortic balloon pump (IABP) in adult patients with a total cavopulmonary, or Fontan circulation.\n \n \n \n A patient in his twenties with a Fontan circulation presented with sepsis, pneumonia, and pulmonary edema. He was born with a hypoplastic left ventricle, atrioventricular septal defect, and hypoplastic aortic arch, and a total cavopulmonary circulation had been established within his first years of life. Standard of care treatment with antibiotics, non-invasive ventilatory support, loop diuretics and vasopressors was initiated. Due to persistent pulmonary congestion and increasing general fatigue, an IABP was placed via a femoral artery to offload the failing systemic ventricle. Secondary to IABP treatment, mean arterial pressure rose, and vasodilatory nitroprusside could be introduced. Over four days of IABP treatment, the patient´s general condition and ventricular systolic function improved significantly.\n \n \n \n This case suggests that IABP treatment was important in the recovery of our patient with a Fontan circulation, pneumonia and heart failure. We propose that during IABP treatment, an increase in stroke volume and a reduction in ventricular filling pressure is achieved, thereby increasing the transpulmonary pressure gradient that is central to pulmonary blood flow in Fontan patients. More definitive evidence is necessary to confirm our hypotheses.\n","PeriodicalId":507701,"journal":{"name":"European Heart Journal - Case Reports","volume":"9 8","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-06-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Heart Journal - Case Reports","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/ehjcr/ytae289","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
There is limited evidence for the use of an intra-aortic balloon pump (IABP) in adult patients with a total cavopulmonary, or Fontan circulation.
A patient in his twenties with a Fontan circulation presented with sepsis, pneumonia, and pulmonary edema. He was born with a hypoplastic left ventricle, atrioventricular septal defect, and hypoplastic aortic arch, and a total cavopulmonary circulation had been established within his first years of life. Standard of care treatment with antibiotics, non-invasive ventilatory support, loop diuretics and vasopressors was initiated. Due to persistent pulmonary congestion and increasing general fatigue, an IABP was placed via a femoral artery to offload the failing systemic ventricle. Secondary to IABP treatment, mean arterial pressure rose, and vasodilatory nitroprusside could be introduced. Over four days of IABP treatment, the patient´s general condition and ventricular systolic function improved significantly.
This case suggests that IABP treatment was important in the recovery of our patient with a Fontan circulation, pneumonia and heart failure. We propose that during IABP treatment, an increase in stroke volume and a reduction in ventricular filling pressure is achieved, thereby increasing the transpulmonary pressure gradient that is central to pulmonary blood flow in Fontan patients. More definitive evidence is necessary to confirm our hypotheses.