{"title":"Precision dose prediction for breast cancer patients undergoing IMRT: The Swin-UMamba-Channel Model","authors":"Hui Xie , Hua Zhang , Zijie Chen , Tao Tan","doi":"10.1016/j.compmedimag.2024.102409","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>Radiation therapy is one of the crucial treatment modalities for cancer. An excellent radiation therapy plan relies heavily on an outstanding dose distribution map, which is traditionally generated through repeated trials and adjustments by experienced physicists. However, this process is both time-consuming and labor-intensive, and it comes with a degree of subjectivity. Now, with the powerful capabilities of deep learning, we are able to predict dose distribution maps more accurately, effectively overcoming these challenges.</p></div><div><h3>Methods</h3><p>In this study, we propose a novel Swin-UMamba-Channel prediction model specifically designed for predicting the dose distribution of patients with left breast cancer undergoing radiotherapy after total mastectomy. This model integrates anatomical position information of organs and ray angle information, significantly enhancing prediction accuracy. Through iterative training of the generator (Swin-UMamba) and discriminator, the model can generate images that closely match the actual dose, assisting physicists in quickly creating DVH curves and shortening the treatment planning cycle. Our model exhibits excellent performance in terms of prediction accuracy, computational efficiency, and practicality, and its effectiveness has been further verified through comparative experiments with similar networks.</p></div><div><h3>Results</h3><p>The results of the study indicate that our model can accurately predict the clinical dose of breast cancer patients undergoing intensity-modulated radiation therapy (IMRT). The predicted dose range is from 0 to 50 Gy, and compared with actual data, it shows a high accuracy with an average Dice similarity coefficient of 0.86. Specifically, the average dose change rate for the planning target volume ranges from 0.28 % to 1.515 %, while the average dose change rates for the right and left lungs are 2.113 % and 0.508 %, respectively. Notably, due to their small sizes, the heart and spinal cord exhibit relatively higher average dose change rates, reaching 3.208 % and 1.490 %, respectively. In comparison with similar dose studies, our model demonstrates superior performance. Additionally, our model possesses fewer parameters, lower computational complexity, and shorter processing time, further enhancing its practicality and efficiency. These findings provide strong evidence for the accuracy and reliability of our model in predicting doses, offering significant technical support for IMRT in breast cancer patients.</p></div><div><h3>Conclusion</h3><p>This study presents a novel Swin-UMamba-Channel dose prediction model, and its results demonstrate its precise prediction of clinical doses for the target area of left breast cancer patients undergoing total mastectomy and IMRT. These remarkable achievements provide valuable reference data for subsequent plan optimization and quality control, paving a new path for the application of deep learning in the field of radiation therapy.</p></div>","PeriodicalId":50631,"journal":{"name":"Computerized Medical Imaging and Graphics","volume":"116 ","pages":"Article 102409"},"PeriodicalIF":5.4000,"publicationDate":"2024-06-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Computerized Medical Imaging and Graphics","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0895611124000867","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Background
Radiation therapy is one of the crucial treatment modalities for cancer. An excellent radiation therapy plan relies heavily on an outstanding dose distribution map, which is traditionally generated through repeated trials and adjustments by experienced physicists. However, this process is both time-consuming and labor-intensive, and it comes with a degree of subjectivity. Now, with the powerful capabilities of deep learning, we are able to predict dose distribution maps more accurately, effectively overcoming these challenges.
Methods
In this study, we propose a novel Swin-UMamba-Channel prediction model specifically designed for predicting the dose distribution of patients with left breast cancer undergoing radiotherapy after total mastectomy. This model integrates anatomical position information of organs and ray angle information, significantly enhancing prediction accuracy. Through iterative training of the generator (Swin-UMamba) and discriminator, the model can generate images that closely match the actual dose, assisting physicists in quickly creating DVH curves and shortening the treatment planning cycle. Our model exhibits excellent performance in terms of prediction accuracy, computational efficiency, and practicality, and its effectiveness has been further verified through comparative experiments with similar networks.
Results
The results of the study indicate that our model can accurately predict the clinical dose of breast cancer patients undergoing intensity-modulated radiation therapy (IMRT). The predicted dose range is from 0 to 50 Gy, and compared with actual data, it shows a high accuracy with an average Dice similarity coefficient of 0.86. Specifically, the average dose change rate for the planning target volume ranges from 0.28 % to 1.515 %, while the average dose change rates for the right and left lungs are 2.113 % and 0.508 %, respectively. Notably, due to their small sizes, the heart and spinal cord exhibit relatively higher average dose change rates, reaching 3.208 % and 1.490 %, respectively. In comparison with similar dose studies, our model demonstrates superior performance. Additionally, our model possesses fewer parameters, lower computational complexity, and shorter processing time, further enhancing its practicality and efficiency. These findings provide strong evidence for the accuracy and reliability of our model in predicting doses, offering significant technical support for IMRT in breast cancer patients.
Conclusion
This study presents a novel Swin-UMamba-Channel dose prediction model, and its results demonstrate its precise prediction of clinical doses for the target area of left breast cancer patients undergoing total mastectomy and IMRT. These remarkable achievements provide valuable reference data for subsequent plan optimization and quality control, paving a new path for the application of deep learning in the field of radiation therapy.
期刊介绍:
The purpose of the journal Computerized Medical Imaging and Graphics is to act as a source for the exchange of research results concerning algorithmic advances, development, and application of digital imaging in disease detection, diagnosis, intervention, prevention, precision medicine, and population health. Included in the journal will be articles on novel computerized imaging or visualization techniques, including artificial intelligence and machine learning, augmented reality for surgical planning and guidance, big biomedical data visualization, computer-aided diagnosis, computerized-robotic surgery, image-guided therapy, imaging scanning and reconstruction, mobile and tele-imaging, radiomics, and imaging integration and modeling with other information relevant to digital health. The types of biomedical imaging include: magnetic resonance, computed tomography, ultrasound, nuclear medicine, X-ray, microwave, optical and multi-photon microscopy, video and sensory imaging, and the convergence of biomedical images with other non-imaging datasets.