Davide Farronato, Leonardo Romano, Gabriele Dani, Giuseppe Messina, Benedetta Miceli, Lorenzo Azzi
{"title":"A Conservative Technique for Fractured Implant Abutment Screw Retrieval on an Internal Connection Implant: Proof of Concept.","authors":"Davide Farronato, Leonardo Romano, Gabriele Dani, Giuseppe Messina, Benedetta Miceli, Lorenzo Azzi","doi":"10.1563/aaid-joi-D-24-00064","DOIUrl":null,"url":null,"abstract":"<p><p>Broken screw removal from the implant connection is a common but challenging process. Several proposed methods and technical solutions may result in unsuccessful removal; thus, a novel, more conservative, risk-free method is proposed as a first attempt. The proposal is to use a silicon restoration holder to be twisted counterclockwise on the dried surface of the broken fragment inside the implant connection. This method, within the limitations of a minimal case series, yielded 100% results; however, despite previous attempts with less conservative techniques, this approach showed no efficacy. This article aims to promote the use of silicon restoration holders as a minimally invasive first attempt at broken screw retrieval treatment before considering other options.</p>","PeriodicalId":519890,"journal":{"name":"The Journal of oral implantology","volume":" ","pages":"519-523"},"PeriodicalIF":0.0000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Journal of oral implantology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1563/aaid-joi-D-24-00064","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Broken screw removal from the implant connection is a common but challenging process. Several proposed methods and technical solutions may result in unsuccessful removal; thus, a novel, more conservative, risk-free method is proposed as a first attempt. The proposal is to use a silicon restoration holder to be twisted counterclockwise on the dried surface of the broken fragment inside the implant connection. This method, within the limitations of a minimal case series, yielded 100% results; however, despite previous attempts with less conservative techniques, this approach showed no efficacy. This article aims to promote the use of silicon restoration holders as a minimally invasive first attempt at broken screw retrieval treatment before considering other options.