Posterolateral wall integrity in reverse oblique intertrochanteric fracture fixation: A new perspective in evaluation.

Ahmed Majid Heydar, Görkem Kıyak
{"title":"Posterolateral wall integrity in reverse oblique intertrochanteric fracture fixation: A new perspective in evaluation.","authors":"Ahmed Majid Heydar, Görkem Kıyak","doi":"10.14744/tjtes.2024.35808","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Treatment of reverse oblique fractures has the highest complication rate among proximal femur fractures. Although intramedullary nailing is the preferred treatment option, a high failure rate has been reported. Previous studies have identified several contributing factors to these failures, yet the significance of posterolateral wall integrity in ensuring postoperative stability has not been emphasized. This study aims to investigate the impact of posterolateral wall integrity on the failure rates of reverse oblique intertrochanteric fractures treated with intramedullary nails (IMN) and assess the vulnerability of certain IMN designs to these failures.</p><p><strong>Methods: </strong>Between 2010 and 2016, 53 patients with reverse oblique fractures were analyzed to identify factors associated with IMN failure. Variables such as posterolateral wall integrity, quality of reduction, posteromedial support, and IMN design were considered as potential risk factors. Logistic regression analysis was conducted to evaluate these risk factors, with statistical significance defined as p<0.05.</p><p><strong>Results: </strong>Eleven cases of implant failure were identified. Univariate statistical analysis indicated that loss of posterolateral support (p=0.002), IMN with single-screw proximal fixation (p=0.048), poor reduction quality (p=0.004), and loss of posteromedial support (p=0.040) were associated with implant failure. Multivariate analysis confirmed loss of posterolateral support (p=0.009), poor reduction quality (p=0.039), and loss of posteromedial support (p=0.020) as independent risk factors for failure. However, IMN with single proximal fixation (p=0.859) did not significantly impact fixation failure.</p><p><strong>Conclusion: </strong>Reverse oblique intertrochanteric fractures with compromised posterolateral support exhibit a high rate of mechanical failure when treated with IMN. Additionally, poor reduction quality and loss of posteromedial support increase the risk for failure of these fractures. An IMN design featuring dual separate proximal screw fixations could provide better stability compared to a design with a single proximal screw, thereby reducing the risk of mechanical failure.</p>","PeriodicalId":94263,"journal":{"name":"Ulusal travma ve acil cerrahi dergisi = Turkish journal of trauma & emergency surgery : TJTES","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11230043/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ulusal travma ve acil cerrahi dergisi = Turkish journal of trauma & emergency surgery : TJTES","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14744/tjtes.2024.35808","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Treatment of reverse oblique fractures has the highest complication rate among proximal femur fractures. Although intramedullary nailing is the preferred treatment option, a high failure rate has been reported. Previous studies have identified several contributing factors to these failures, yet the significance of posterolateral wall integrity in ensuring postoperative stability has not been emphasized. This study aims to investigate the impact of posterolateral wall integrity on the failure rates of reverse oblique intertrochanteric fractures treated with intramedullary nails (IMN) and assess the vulnerability of certain IMN designs to these failures.

Methods: Between 2010 and 2016, 53 patients with reverse oblique fractures were analyzed to identify factors associated with IMN failure. Variables such as posterolateral wall integrity, quality of reduction, posteromedial support, and IMN design were considered as potential risk factors. Logistic regression analysis was conducted to evaluate these risk factors, with statistical significance defined as p<0.05.

Results: Eleven cases of implant failure were identified. Univariate statistical analysis indicated that loss of posterolateral support (p=0.002), IMN with single-screw proximal fixation (p=0.048), poor reduction quality (p=0.004), and loss of posteromedial support (p=0.040) were associated with implant failure. Multivariate analysis confirmed loss of posterolateral support (p=0.009), poor reduction quality (p=0.039), and loss of posteromedial support (p=0.020) as independent risk factors for failure. However, IMN with single proximal fixation (p=0.859) did not significantly impact fixation failure.

Conclusion: Reverse oblique intertrochanteric fractures with compromised posterolateral support exhibit a high rate of mechanical failure when treated with IMN. Additionally, poor reduction quality and loss of posteromedial support increase the risk for failure of these fractures. An IMN design featuring dual separate proximal screw fixations could provide better stability compared to a design with a single proximal screw, thereby reducing the risk of mechanical failure.

反向斜行转子间骨折固定中的后侧壁完整性:评估的新视角。
背景:在股骨近端骨折中,反向斜行骨折的并发症发生率最高。虽然髓内钉是首选的治疗方案,但有报道称失败率很高。以往的研究发现了导致这些失败的几个因素,但并没有强调后侧壁完整性对确保术后稳定性的重要意义。本研究旨在调查后侧壁完整性对使用髓内钉(IMN)治疗反向斜转子间骨折失败率的影响,并评估某些 IMN 设计对这些失败的脆弱性:方法: 在2010年至2016年期间,对53例反向斜行骨折患者进行了分析,以确定与IMN失败相关的因素。后侧壁完整性、还原质量、后内侧支撑和IMN设计等变量被视为潜在风险因素。对这些风险因素进行了逻辑回归分析,统计显著性定义为 pResults:共发现 11 例种植失败病例。单变量统计分析显示,后外侧支持缺失(p=0.002)、单螺钉近端固定的 IMN(p=0.048)、还原质量差(p=0.004)和后内侧支持缺失(p=0.040)与种植失败有关。多变量分析证实,后外侧支持丧失(p=0.009)、还原质量差(p=0.039)和后内侧支持丧失(p=0.020)是导致失败的独立风险因素。然而,单近端固定的IMN(p=0.859)对固定失败没有显著影响:结论:采用 IMN 治疗后外侧支撑受损的反向斜行转子间骨折时,机械固定失败率较高。此外,较差的还原质量和后内侧支撑的丧失也会增加这些骨折失败的风险。与使用单根近端螺钉的设计相比,采用双根独立近端螺钉固定的 IMN 设计可以提供更好的稳定性,从而降低机械性骨折失败的风险。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信