{"title":"Identifying time-varying dynamics of heart rate and oxygen uptake from single ramp incremental running tests.","authors":"Jasper Gielen, Loes Stessens, Romain Meeusen, Jean-Marie Aerts","doi":"10.1088/1361-6579/ad56f7","DOIUrl":null,"url":null,"abstract":"<p><p><i>Objective.</i>The fact that ramp incremental exercise yields quasi-linear responses for pulmonary oxygen uptake (V˙O2) and heart rate (HR) seems contradictory to the well-known non-linear behavior of underlying physiological processes. Prior research highlights this issue and demonstrates how a balancing of system gain and response time parameters causes linearV˙O2responses during ramp tests. This study builds upon this knowledge and extracts the time-varying dynamics directly from HR andV˙O2data of single ramp incremental running tests.<i>Approach.</i>A large-scale open access dataset of 735 ramp incremental running tests is analyzed. The dynamics are obtained by means of 1st order autoregressive and exogenous models with time-variant parameters. This allows for the estimates of time constant (<i>τ</i>) and steady state gain (SSG) to vary with work rate.<i>Main results.</i>As the work rate increases,<i>τ</i>-values increase on average from 38 to 132 s for HR, and from 27 to 35 s forV˙O2. Both increases are statistically significant (<i>p</i>< 0.01). Further, SSG-values decrease on average from 14 to 9 bpm (km·h<sup>-1</sup>)<sup>-1</sup>for HR, and from 218 to 144 ml·min<sup>-1</sup>forV˙O2(<i>p</i>< 0.01 for decrease parameters of HR andV˙O2). The results of this modeling approach are line with literature reporting on cardiorespiratory dynamics obtained using standard procedures.<i>Significance.</i>We show that time-variant modeling is able to determine the time-varying dynamics HR andV˙O2responses to ramp incremental running directly from individual tests. The proposed method allows for gaining insights into the cardiorespiratory response characteristics when no repeated measurements are available.</p>","PeriodicalId":20047,"journal":{"name":"Physiological measurement","volume":null,"pages":null},"PeriodicalIF":2.3000,"publicationDate":"2024-06-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physiological measurement","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1088/1361-6579/ad56f7","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"BIOPHYSICS","Score":null,"Total":0}
引用次数: 0
Abstract
Objective.The fact that ramp incremental exercise yields quasi-linear responses for pulmonary oxygen uptake (V˙O2) and heart rate (HR) seems contradictory to the well-known non-linear behavior of underlying physiological processes. Prior research highlights this issue and demonstrates how a balancing of system gain and response time parameters causes linearV˙O2responses during ramp tests. This study builds upon this knowledge and extracts the time-varying dynamics directly from HR andV˙O2data of single ramp incremental running tests.Approach.A large-scale open access dataset of 735 ramp incremental running tests is analyzed. The dynamics are obtained by means of 1st order autoregressive and exogenous models with time-variant parameters. This allows for the estimates of time constant (τ) and steady state gain (SSG) to vary with work rate.Main results.As the work rate increases,τ-values increase on average from 38 to 132 s for HR, and from 27 to 35 s forV˙O2. Both increases are statistically significant (p< 0.01). Further, SSG-values decrease on average from 14 to 9 bpm (km·h-1)-1for HR, and from 218 to 144 ml·min-1forV˙O2(p< 0.01 for decrease parameters of HR andV˙O2). The results of this modeling approach are line with literature reporting on cardiorespiratory dynamics obtained using standard procedures.Significance.We show that time-variant modeling is able to determine the time-varying dynamics HR andV˙O2responses to ramp incremental running directly from individual tests. The proposed method allows for gaining insights into the cardiorespiratory response characteristics when no repeated measurements are available.
期刊介绍:
Physiological Measurement publishes papers about the quantitative assessment and visualization of physiological function in clinical research and practice, with an emphasis on the development of new methods of measurement and their validation.
Papers are published on topics including:
applied physiology in illness and health
electrical bioimpedance, optical and acoustic measurement techniques
advanced methods of time series and other data analysis
biomedical and clinical engineering
in-patient and ambulatory monitoring
point-of-care technologies
novel clinical measurements of cardiovascular, neurological, and musculoskeletal systems.
measurements in molecular, cellular and organ physiology and electrophysiology
physiological modeling and simulation
novel biomedical sensors, instruments, devices and systems