Christopher Thomas, Isabel Dregely, I. Oksuz, Teresa Guerrero Urbano, T. Greener, Andrew P King, Sally F Barrington
{"title":"Effect of synthetic CT on dose-derived toxicity predictors for MR-only prostate radiotherapy","authors":"Christopher Thomas, Isabel Dregely, I. Oksuz, Teresa Guerrero Urbano, T. Greener, Andrew P King, Sally F Barrington","doi":"10.1093/bjro/tzae014","DOIUrl":null,"url":null,"abstract":"\n \n \n Toxicity-driven adaptive radiotherapy (RT) is enhanced by the superior soft tissue contrast of magnetic resonance (MR) imaging compared with conventional computed tomography (CT). However, in an MR-only RT pathway synthetic CTs (sCT) are required for dose calculation. This study evaluates 3 sCT approaches for accurate rectal toxicity prediction in prostate RT.\n \n \n \n Thirty-six patients had MR (T2-weighted acquisition optimised for anatomical delineation, and T1-Dixon) with same day standard-of-care planning CT for prostate RT. Multiple sCT were created per patient using bulk density (BD), tissue stratification (TS, from T1-Dixon) and deep-learning (DL) artificial intelligence (AI) (from T2-weighted) approaches for dose distribution calculation and creation of rectal dose volume histograms (DVH) and dose surface maps (DSM) to assess grade-2 (G2) rectal bleeding risk.\n \n \n \n Maximum absolute errors using sCT for DVH-based G2 rectal bleeding risk (risk range 1.6% to 6.1%) were 0.6% (BD), 0.3% (TS) and 0.1% (DL). DSM-derived risk prediction errors followed a similar pattern. DL sCT has voxel-wise density generated from T2-weighted MR and improved accuracy for both risk-prediction methods.\n \n \n \n DL improves dosimetric and predicted risk calculation accuracy. Both TS and DL methods are clinically suitable for sCT generation in toxicity-guided RT, however DL offers increased accuracy and offers efficiencies by removing the need for T1-Dixon MR.\n \n \n \n This study demonstrates novel insights regarding the effect of sCT on predictive toxicity metrics, demonstrating clear accuracy improvement with increased sCT resolution. Accuracy of toxicity calculation in MR-only RT should be assessed for all treatment sites where dose to critical structures will guide adaptive-RT strategies.\n","PeriodicalId":516126,"journal":{"name":"BJR|Open","volume":"47 48","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-06-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BJR|Open","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/bjro/tzae014","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Toxicity-driven adaptive radiotherapy (RT) is enhanced by the superior soft tissue contrast of magnetic resonance (MR) imaging compared with conventional computed tomography (CT). However, in an MR-only RT pathway synthetic CTs (sCT) are required for dose calculation. This study evaluates 3 sCT approaches for accurate rectal toxicity prediction in prostate RT.
Thirty-six patients had MR (T2-weighted acquisition optimised for anatomical delineation, and T1-Dixon) with same day standard-of-care planning CT for prostate RT. Multiple sCT were created per patient using bulk density (BD), tissue stratification (TS, from T1-Dixon) and deep-learning (DL) artificial intelligence (AI) (from T2-weighted) approaches for dose distribution calculation and creation of rectal dose volume histograms (DVH) and dose surface maps (DSM) to assess grade-2 (G2) rectal bleeding risk.
Maximum absolute errors using sCT for DVH-based G2 rectal bleeding risk (risk range 1.6% to 6.1%) were 0.6% (BD), 0.3% (TS) and 0.1% (DL). DSM-derived risk prediction errors followed a similar pattern. DL sCT has voxel-wise density generated from T2-weighted MR and improved accuracy for both risk-prediction methods.
DL improves dosimetric and predicted risk calculation accuracy. Both TS and DL methods are clinically suitable for sCT generation in toxicity-guided RT, however DL offers increased accuracy and offers efficiencies by removing the need for T1-Dixon MR.
This study demonstrates novel insights regarding the effect of sCT on predictive toxicity metrics, demonstrating clear accuracy improvement with increased sCT resolution. Accuracy of toxicity calculation in MR-only RT should be assessed for all treatment sites where dose to critical structures will guide adaptive-RT strategies.