Red dichromatic imaging and linked color imaging as reliable image-enhanced endoscopic procedures for detecting the distal end of the palisade vessels in the columnar metaplastic mucosa of the gastroesophageal junction zone.
{"title":"Red dichromatic imaging and linked color imaging as reliable image-enhanced endoscopic procedures for detecting the distal end of the palisade vessels in the columnar metaplastic mucosa of the gastroesophageal junction zone.","authors":"Satoshi Ono, Keiko Yamamoto, Fumiaki Ishibashi, Ai Fujimoto, Yuji Urabe, Tsutomu Takeda, Hideki Ishikawa, Mitsuhiro Fujishiro, Takuji Gotoda, Michio Kaminishi, Kentaro Sugano","doi":"10.1007/s00535-024-02118-7","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>There is a consensus that identifying the distal end of the palisade vessels (DEPV) is important for diagnosing gastroesophageal junction (GEJ). However, optimum observation methods have not been established. This study investigated the use of effective image-enhanced endoscopy (IEE) for DEPV detection.</p><p><strong>Methods: </strong>One hundred endoscopic images in 20 cases of columnar metaplastic mucosa of the GEJ recorded with white-light imaging (Olympus-WLI and Fujifilm-WLI) and IEEs (narrow-band imaging; RDI1/2/3, red dichromatic imaging; texture and color enhancement imaging 1/2; blue-laser imaging; and LCI, linked color imaging) from two manufacturers were extracted and evaluated by 10 evaluators. Up to 24 radial straight lines from the center of the lumen were placed on the image, and the evaluators placed markings according to confidence level (high, low, and not detectable) at the DEPV locations. The detectability and reproducibility at the rate of the confidence level and coefficient of variance of markings among the evaluator were analyzed.</p><p><strong>Results: </strong>In total, 15,180 markings were obtained. In terms of detectability, RDI1 (49.4%), RDI2 (53.0%), RDI3 (54.1%), TXI2 (49.7%), and LCI (34.6%) had a significantly higher rate of high confidence among the IEEs in each manufacturer. By contrast, Olympus-WLI (40.6%), Fujifilm-WLI (17.6%), narrow-band imaging (15.9%), and blue laser imaging (9.8%) presented with a significantly lower rates of high confidence. Regarding reproducibility, RDI3 and LCI had the lowest coefficient of variance for each manufacturer.</p><p><strong>Conclusions: </strong>RDI and LCI could be reliable modalities for detecting DEPVs in the columnar metaplastic mucosa of the GEJ zone.</p>","PeriodicalId":16059,"journal":{"name":"Journal of Gastroenterology","volume":" ","pages":"647-657"},"PeriodicalIF":6.9000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Gastroenterology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00535-024-02118-7","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/5 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"GASTROENTEROLOGY & HEPATOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Background: There is a consensus that identifying the distal end of the palisade vessels (DEPV) is important for diagnosing gastroesophageal junction (GEJ). However, optimum observation methods have not been established. This study investigated the use of effective image-enhanced endoscopy (IEE) for DEPV detection.
Methods: One hundred endoscopic images in 20 cases of columnar metaplastic mucosa of the GEJ recorded with white-light imaging (Olympus-WLI and Fujifilm-WLI) and IEEs (narrow-band imaging; RDI1/2/3, red dichromatic imaging; texture and color enhancement imaging 1/2; blue-laser imaging; and LCI, linked color imaging) from two manufacturers were extracted and evaluated by 10 evaluators. Up to 24 radial straight lines from the center of the lumen were placed on the image, and the evaluators placed markings according to confidence level (high, low, and not detectable) at the DEPV locations. The detectability and reproducibility at the rate of the confidence level and coefficient of variance of markings among the evaluator were analyzed.
Results: In total, 15,180 markings were obtained. In terms of detectability, RDI1 (49.4%), RDI2 (53.0%), RDI3 (54.1%), TXI2 (49.7%), and LCI (34.6%) had a significantly higher rate of high confidence among the IEEs in each manufacturer. By contrast, Olympus-WLI (40.6%), Fujifilm-WLI (17.6%), narrow-band imaging (15.9%), and blue laser imaging (9.8%) presented with a significantly lower rates of high confidence. Regarding reproducibility, RDI3 and LCI had the lowest coefficient of variance for each manufacturer.
Conclusions: RDI and LCI could be reliable modalities for detecting DEPVs in the columnar metaplastic mucosa of the GEJ zone.
期刊介绍:
The Journal of Gastroenterology, which is the official publication of the Japanese Society of Gastroenterology, publishes Original Articles (Alimentary Tract/Liver, Pancreas, and Biliary Tract), Review Articles, Letters to the Editors and other articles on all aspects of the field of gastroenterology. Significant contributions relating to basic research, theory, and practice are welcomed. These publications are designed to disseminate knowledge in this field to a worldwide audience, and accordingly, its editorial board has an international membership.