Gradient magnetic field measurement using first-order gradiometers equipped with 50 mm diameter pickup coils made out of a 2G high-Tc superconducting tape
{"title":"Gradient magnetic field measurement using first-order gradiometers equipped with 50 mm diameter pickup coils made out of a 2G high-Tc superconducting tape","authors":"Kazunori Komori , Shunichi Arisawa , Minoru Tachiki , Shuuichi Ooi , Tadayuki Hayashi , Kazuhiro Endo","doi":"10.1016/j.physc.2024.1354519","DOIUrl":null,"url":null,"abstract":"<div><p>Two types of first-order gradiometers equipped with 50 mm diameter pickup coils were made out of an REBaCuO High-<em>T</em><sub>c</sub> superconducting (HTS) flexible tape. The HTS tapes were formed into the HTS gradiometers by ``cut-and-wind'' method without cable jointing.</p><p>The HTS gradiometers were examined at 77 K for magnetic sensitivity to a gradient field applied by an external coil. The axial-type HTS gradiometer eliminated the magnetic field output of the device induced by a uniform field, and enhanced the magnetic field output induced by a gradient field on the axis of the pickup coil. The planar-type HTS gradiometer made it possible to detect a 20 mm diameter steel cylinder placed beside the pickup coil in a uniform field of 100 µT by detecting the spatial field gradient in the vicinity of a ferromagnetic object.</p></div>","PeriodicalId":20159,"journal":{"name":"Physica C-superconductivity and Its Applications","volume":"622 ","pages":"Article 1354519"},"PeriodicalIF":1.3000,"publicationDate":"2024-06-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physica C-superconductivity and Its Applications","FirstCategoryId":"101","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0921453424000844","RegionNum":3,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PHYSICS, APPLIED","Score":null,"Total":0}
引用次数: 0
Abstract
Two types of first-order gradiometers equipped with 50 mm diameter pickup coils were made out of an REBaCuO High-Tc superconducting (HTS) flexible tape. The HTS tapes were formed into the HTS gradiometers by ``cut-and-wind'' method without cable jointing.
The HTS gradiometers were examined at 77 K for magnetic sensitivity to a gradient field applied by an external coil. The axial-type HTS gradiometer eliminated the magnetic field output of the device induced by a uniform field, and enhanced the magnetic field output induced by a gradient field on the axis of the pickup coil. The planar-type HTS gradiometer made it possible to detect a 20 mm diameter steel cylinder placed beside the pickup coil in a uniform field of 100 µT by detecting the spatial field gradient in the vicinity of a ferromagnetic object.
期刊介绍:
Physica C (Superconductivity and its Applications) publishes peer-reviewed papers on novel developments in the field of superconductivity. Topics include discovery of new superconducting materials and elucidation of their mechanisms, physics of vortex matter, enhancement of critical properties of superconductors, identification of novel properties and processing methods that improve their performance and promote new routes to applications of superconductivity.
The main goal of the journal is to publish:
1. Papers that substantially increase the understanding of the fundamental aspects and mechanisms of superconductivity and vortex matter through theoretical and experimental methods.
2. Papers that report on novel physical properties and processing of materials that substantially enhance their critical performance.
3. Papers that promote new or improved routes to applications of superconductivity and/or superconducting materials, and proof-of-concept novel proto-type superconducting devices.
The editors of the journal will select papers that are well written and based on thorough research that provide truly novel insights.