{"title":"Deep learning in the precise assessment of primary Sjögren's syndrome based on ultrasound images.","authors":"Xinyue Niu, Yujie Zhou, Jin Xu, Qin Xue, Xiaoyan Xu, Jia Li, Ling Wang, Tianyu Tang","doi":"10.1093/rheumatology/keae312","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>This study aimed to investigate the value of a deep learning (DL) model based on greyscale ultrasound (US) images for precise assessment and accurate diagnosis of primary Sjögren's syndrome (pSS).</p><p><strong>Methods: </strong>This was a multicentre prospective analysis. All pSS patients were diagnosed according to 2016 ACR/EULAR criteria. A total of 72 pSS patients and 72 sex- and age-matched healthy controls recruited between January 2022 and April 2023, together with 41 patients and 41 healthy controls recruited from June 2023 to February 2024 were used for DL model development and validation, respectively. The DL model was constructed based on the ResNet 50 input with preprocessed all participants' bilateral submandibular glands (SMGs), parotid glands (PGs), and lacrimal glands (LGs) greyscale US images. Diagnostic performance of the model was compared with two radiologists. The accuracy of prediction and identification performance of DL model were evaluated by calibration curve.</p><p><strong>Results: </strong>A total of 864 and 164 greyscale US images of SMGs, PGs, and LGs were collected for development and validation of the model. The area under the ROC (AUCs) of DL model in the SMGs, PGs, and LGs were 0.92, 0.93, 0.91 in the model cohort, and were 0.90, 0.88, 0.87 in the validation cohort, respectively, outperforming both radiologists. Calibration curves showed the prediction probability of the DL model was consistent with the actual probability in both model cohort and validation cohort.</p><p><strong>Conclusion: </strong>The DL model based on greyscale US images showed diagnostic potential in the precise assessment of pSS patients in the SMGs, PGs and LGs, outperforming conventional radiologist evaluation.</p>","PeriodicalId":21255,"journal":{"name":"Rheumatology","volume":" ","pages":"2242-2251"},"PeriodicalIF":4.7000,"publicationDate":"2025-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Rheumatology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/rheumatology/keae312","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RHEUMATOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Objectives: This study aimed to investigate the value of a deep learning (DL) model based on greyscale ultrasound (US) images for precise assessment and accurate diagnosis of primary Sjögren's syndrome (pSS).
Methods: This was a multicentre prospective analysis. All pSS patients were diagnosed according to 2016 ACR/EULAR criteria. A total of 72 pSS patients and 72 sex- and age-matched healthy controls recruited between January 2022 and April 2023, together with 41 patients and 41 healthy controls recruited from June 2023 to February 2024 were used for DL model development and validation, respectively. The DL model was constructed based on the ResNet 50 input with preprocessed all participants' bilateral submandibular glands (SMGs), parotid glands (PGs), and lacrimal glands (LGs) greyscale US images. Diagnostic performance of the model was compared with two radiologists. The accuracy of prediction and identification performance of DL model were evaluated by calibration curve.
Results: A total of 864 and 164 greyscale US images of SMGs, PGs, and LGs were collected for development and validation of the model. The area under the ROC (AUCs) of DL model in the SMGs, PGs, and LGs were 0.92, 0.93, 0.91 in the model cohort, and were 0.90, 0.88, 0.87 in the validation cohort, respectively, outperforming both radiologists. Calibration curves showed the prediction probability of the DL model was consistent with the actual probability in both model cohort and validation cohort.
Conclusion: The DL model based on greyscale US images showed diagnostic potential in the precise assessment of pSS patients in the SMGs, PGs and LGs, outperforming conventional radiologist evaluation.
期刊介绍:
Rheumatology strives to support research and discovery by publishing the highest quality original scientific papers with a focus on basic, clinical and translational research. The journal’s subject areas cover a wide range of paediatric and adult rheumatological conditions from an international perspective. It is an official journal of the British Society for Rheumatology, published by Oxford University Press.
Rheumatology publishes original articles, reviews, editorials, guidelines, concise reports, meta-analyses, original case reports, clinical vignettes, letters and matters arising from published material. The journal takes pride in serving the global rheumatology community, with a focus on high societal impact in the form of podcasts, videos and extended social media presence, and utilizing metrics such as Altmetric. Keep up to date by following the journal on Twitter @RheumJnl.