{"title":"A Novel Cooling Device for Kidney Transplant Surgery.","authors":"Ali Dergham, Luke Witherspoon, Liam Power, Joseph Y Nashed, Thomas A A Skinner","doi":"10.1177/15533506241260087","DOIUrl":null,"url":null,"abstract":"<p><p><b>Background:</b> Prolonged warm ischemia time (WIT) in kidney transplantation is associated with numerous adverse outcomes including delayed graft function and decreased patient and graft survival. Circumventing WIT lies in maintaining renal hypothermia and efficiently performing the vascular anastomosis during this portion of the procedure. Although numerous methods of intra-operative renal cooling have been proposed, most suffer from practical limitations, and none have been widely adopted. Herein we describe a novel device specifically designed to maintain renal hypothermia during kidney transplant surgery.<b>Methods:</b> Aluminum tubing was organized in a serpentine pattern to create a malleable, form-fitting cooling jacket to manipulate renal allografts during transplant surgery. Adult porcine kidneys were used to test the device with 4°C saline as coolant. Kidneys were placed at 24°C; surface and core temperatures were monitored using implanted thermocouples. Anastomosis of porcine kidney vessels to GORE-TEX® vascular grafts in an ex-vivo operative field was performed to assess the functionality of the device.<b>Results:</b> The device maintained surface and core graft temperatures of ≤5°C after 60 minutes of WIT. Furthermore, the device provided hands-free retraction and support for the allograft. We found that ex-vivo anastomosis testing was enhanced by the presence of the cooling jacket.<b>Conclusions:</b> This proof-of-concept study demonstrated that our novel device is a practical tool for renal transplantation and can maintain sufficiently cool graft temperatures to mitigate WIT in an ex-vivo setting. This device is the first of its kind and has the potential to improve kidney transplant outcomes by eliminating WIT during graft implantation.</p>","PeriodicalId":22095,"journal":{"name":"Surgical Innovation","volume":null,"pages":null},"PeriodicalIF":1.2000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11264556/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Surgical Innovation","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/15533506241260087","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/3 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Prolonged warm ischemia time (WIT) in kidney transplantation is associated with numerous adverse outcomes including delayed graft function and decreased patient and graft survival. Circumventing WIT lies in maintaining renal hypothermia and efficiently performing the vascular anastomosis during this portion of the procedure. Although numerous methods of intra-operative renal cooling have been proposed, most suffer from practical limitations, and none have been widely adopted. Herein we describe a novel device specifically designed to maintain renal hypothermia during kidney transplant surgery.Methods: Aluminum tubing was organized in a serpentine pattern to create a malleable, form-fitting cooling jacket to manipulate renal allografts during transplant surgery. Adult porcine kidneys were used to test the device with 4°C saline as coolant. Kidneys were placed at 24°C; surface and core temperatures were monitored using implanted thermocouples. Anastomosis of porcine kidney vessels to GORE-TEX® vascular grafts in an ex-vivo operative field was performed to assess the functionality of the device.Results: The device maintained surface and core graft temperatures of ≤5°C after 60 minutes of WIT. Furthermore, the device provided hands-free retraction and support for the allograft. We found that ex-vivo anastomosis testing was enhanced by the presence of the cooling jacket.Conclusions: This proof-of-concept study demonstrated that our novel device is a practical tool for renal transplantation and can maintain sufficiently cool graft temperatures to mitigate WIT in an ex-vivo setting. This device is the first of its kind and has the potential to improve kidney transplant outcomes by eliminating WIT during graft implantation.

用于肾移植手术的新型冷却装置
背景:肾移植手术中延长暖缺血时间(WIT)与多种不良后果有关,包括移植功能延迟、患者和移植物存活率降低。避免WIT的关键在于保持肾脏低温,并在手术过程中有效地进行血管吻合。虽然已经提出了许多术中肾脏降温的方法,但大多数方法都存在实际局限性,没有一种方法被广泛采用。在此,我们介绍一种专门用于在肾移植手术中维持肾脏低温的新型装置:方法:将铝管编织成蛇形图案,形成一个可塑性强、贴合形状的冷却套,以便在移植手术中操作肾脏异体移植物。用成年猪肾脏测试以4°C生理盐水为冷却剂的装置。将肾脏置于 24°C 的温度下;使用植入的热电偶监测表面和核心温度。在体外手术区将猪肾血管与 GORE-TEX® 血管移植物吻合,以评估该装置的功能:结果:WIT 60 分钟后,该装置可保持移植物表面和核心温度≤5°C。此外,该装置还能为同种异体移植物提供免提牵引和支撑。我们发现,体内吻合测试因冷却套的存在而得到加强:这项概念验证研究表明,我们的新型装置是肾移植的实用工具,可以在体外环境中保持足够低的移植物温度,从而减轻 WIT 的影响。这种装置是同类产品中的首创,有望在移植物植入过程中消除 WIT,从而改善肾移植效果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Surgical Innovation
Surgical Innovation 医学-外科
CiteScore
2.90
自引率
0.00%
发文量
72
审稿时长
6-12 weeks
期刊介绍: Surgical Innovation (SRI) is a peer-reviewed bi-monthly journal focusing on minimally invasive surgical techniques, new instruments such as laparoscopes and endoscopes, and new technologies. SRI prepares surgeons to think and work in "the operating room of the future" through learning new techniques, understanding and adapting to new technologies, maintaining surgical competencies, and applying surgical outcomes data to their practices. This journal is a member of the Committee on Publication Ethics (COPE).
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信