Study of the Influence of Cavitation and Magnetic Field on the Change of Water Properties and its Purification in a Vibrating Machine with Determination of Drive Modes

Anatolyi Hordieiev, Galyna Kalda, M. Pashechko, Andriy Hanzyuk, Vitaliy Tkachuk, Nazar Kostiuk
{"title":"Study of the Influence of Cavitation and Magnetic Field on the Change of Water Properties and its Purification in a Vibrating Machine with Determination of Drive Modes","authors":"Anatolyi Hordieiev, Galyna Kalda, M. Pashechko, Andriy Hanzyuk, Vitaliy Tkachuk, Nazar Kostiuk","doi":"10.12913/22998624/186545","DOIUrl":null,"url":null,"abstract":"The paper presents the results of research into the influence of low-frequency sound and magnetic fields on the change in the properties of water and its purification in a vibrating machine with an eccentric drive, which allows obtaining a constant amplitude of oscillation when the frequency of oscillations of the drive is changed. A method and construc - tion of a vibrating machine for changing the properties of water and cleaning is proposed. Thanks to its reciprocating movement, and in the pulsation chamber and the nozzle, appropriate reactions take place. At certain oscillation fre - quencies, a cavitation cavity appears in the nozzle and the pulsation chamber, in which the process of splitting water molecules into active radicals takes place. At the same time, during the reciprocating movement of water through a non-magnetic nozzle, which is covered by permanent magnets, an additional effect of a variable magnetic field direc - tion is exerted on water, which strengthens the breaking of hydrogen bonds in water molecules. Visualization of the hydrocavitation process during operation of a vibrating machine with a transparent nozzle was studied. During the experiment, changes in water parameters were studied, i.e. changes in pH, changes in the oxidation-reduction poten - tial of treatment ORP and the total content of mineralization according to the TDS index with treatment time. The total concentration of dissolved salts decreases from 400 to 300 units, which also indicates an improvement in water quality. The rational frequency limits of the vibration drive of the machine are in the range from 18 to 23 Hz with an amplitude of oscillations of 0.002 m, and the ratio of its design parameters is determined: with a piston diameter of 0.1 m, it is recommended to use a diameter of the hole in the piston from 0.006 to 0.008 m.","PeriodicalId":517116,"journal":{"name":"Advances in Science and Technology Research Journal","volume":"9 8","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advances in Science and Technology Research Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.12913/22998624/186545","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The paper presents the results of research into the influence of low-frequency sound and magnetic fields on the change in the properties of water and its purification in a vibrating machine with an eccentric drive, which allows obtaining a constant amplitude of oscillation when the frequency of oscillations of the drive is changed. A method and construc - tion of a vibrating machine for changing the properties of water and cleaning is proposed. Thanks to its reciprocating movement, and in the pulsation chamber and the nozzle, appropriate reactions take place. At certain oscillation fre - quencies, a cavitation cavity appears in the nozzle and the pulsation chamber, in which the process of splitting water molecules into active radicals takes place. At the same time, during the reciprocating movement of water through a non-magnetic nozzle, which is covered by permanent magnets, an additional effect of a variable magnetic field direc - tion is exerted on water, which strengthens the breaking of hydrogen bonds in water molecules. Visualization of the hydrocavitation process during operation of a vibrating machine with a transparent nozzle was studied. During the experiment, changes in water parameters were studied, i.e. changes in pH, changes in the oxidation-reduction poten - tial of treatment ORP and the total content of mineralization according to the TDS index with treatment time. The total concentration of dissolved salts decreases from 400 to 300 units, which also indicates an improvement in water quality. The rational frequency limits of the vibration drive of the machine are in the range from 18 to 23 Hz with an amplitude of oscillations of 0.002 m, and the ratio of its design parameters is determined: with a piston diameter of 0.1 m, it is recommended to use a diameter of the hole in the piston from 0.006 to 0.008 m.
研究气蚀和磁场对振动机中水性质变化及其净化的影响并确定驱动模式
本文介绍了关于低频声场和磁场对水的性质变化和水净化的影响的研究成果,该振动机带有偏心驱动装置,当驱动装置的振荡频率改变时,可以获得恒定的振荡幅度。本文提出了一种用于改变水的性质和清洁的振动机的方法和构造。由于其往复运动,在脉动室和喷嘴中会发生适当的反应。在一定的振荡频率下,喷嘴和脉动室中会出现一个空化腔,水分子在其中分裂成活性基团。同时,在水通过由永久磁铁覆盖的非磁性喷嘴的往复运动过程中,可变磁场方向会对水产生额外的影响,从而加强水分子中氢键的断裂。研究了带有透明喷嘴的振动机器运行过程中水蚀过程的可视化。在实验过程中,研究了水参数的变化,即 pH 值的变化、处理 ORP 的氧化还原电位的变化以及根据 TDS 指数计算的矿化物总含量随处理时间的变化。溶解盐的总浓度从 400 个单位下降到 300 个单位,这也表明水质有所改善。机器振动驱动的合理频率范围为 18 至 23 赫兹,振幅为 0.002 米,并确定了其设计参数的比率:活塞直径为 0.1 米时,建议使用 0.006 至 0.008 米的活塞孔直径。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信