Validation of transient SYSTEM analysis code GINKGO based on a SLB TEST

Si Si Wang, Ke Wang, Zhong Ying Ma, Ting Wang
{"title":"Validation of transient SYSTEM analysis code GINKGO based on a SLB TEST","authors":"Si Si Wang,&nbsp;Ke Wang,&nbsp;Zhong Ying Ma,&nbsp;Ting Wang","doi":"10.1016/j.jandt.2024.05.006","DOIUrl":null,"url":null,"abstract":"<div><p>Transient System analysis code is an important tool for reactor thermal hydraulic analysis. GINKGO is a transient system analysis in-house code developed by China General Nuclear Power Corporation (CGN). The code is primarily used for the analysis of Non-Loss of Coolant Accident (Non-LOCA)transients. Steam Line Break (SLB) accident is one of the representative accident condition of Non-LOCA transients. To validate the capability of GINKGO to simulate SLB accident scenario, a test of small non-isolatable main steam line break (10 %) at hot standby conditions, PKL III B5.1 test is selected. The characteristic of PKL facility, the PKL III B5.1 test sequence and the validation process of PKL III B5.1 test by GINKGO code are briefly introduced in the paper. In validation process, GINKGO simulates the steady state first and then simulates the transient process by setting reasonable initial conditions and boundary conditions. Then, the calculation results of key parameters including temperature in hot leg, temperature in cold leg, Steam Generator (SG) secondary side pressure and Pressurizer (PZR) pressure are compared with the experimental results. Through the rationality of the calculation results, it shows that GINKGO has the capability to simulate the key phenomena in a typical SLB accident scenario.</p></div>","PeriodicalId":100689,"journal":{"name":"International Journal of Advanced Nuclear Reactor Design and Technology","volume":"6 1","pages":"Pages 1-8"},"PeriodicalIF":0.0000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2468605024000176/pdfft?md5=092f88272be9b36b50ccdd6e9411735f&pid=1-s2.0-S2468605024000176-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Advanced Nuclear Reactor Design and Technology","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2468605024000176","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Transient System analysis code is an important tool for reactor thermal hydraulic analysis. GINKGO is a transient system analysis in-house code developed by China General Nuclear Power Corporation (CGN). The code is primarily used for the analysis of Non-Loss of Coolant Accident (Non-LOCA)transients. Steam Line Break (SLB) accident is one of the representative accident condition of Non-LOCA transients. To validate the capability of GINKGO to simulate SLB accident scenario, a test of small non-isolatable main steam line break (10 %) at hot standby conditions, PKL III B5.1 test is selected. The characteristic of PKL facility, the PKL III B5.1 test sequence and the validation process of PKL III B5.1 test by GINKGO code are briefly introduced in the paper. In validation process, GINKGO simulates the steady state first and then simulates the transient process by setting reasonable initial conditions and boundary conditions. Then, the calculation results of key parameters including temperature in hot leg, temperature in cold leg, Steam Generator (SG) secondary side pressure and Pressurizer (PZR) pressure are compared with the experimental results. Through the rationality of the calculation results, it shows that GINKGO has the capability to simulate the key phenomena in a typical SLB accident scenario.

基于 SLB 测试的传输系统分析代码 GINKGO 验证
瞬态系统分析代码是反应堆热工水力分析的重要工具。GINKGO 是中国通用核能公司(CGN)开发的内部瞬态系统分析代码。该代码主要用于非冷却剂损失事故(Non-LOCA)瞬态分析。蒸汽管线断裂(SLB)事故是非失去冷却剂事故(Non-LOCA)瞬态的代表性事故条件之一。为了验证 GINKGO 模拟蒸汽管线断裂事故的能力,选择了热备用条件下的小型非隔离主蒸汽管线断裂(10%)试验,即 PKL III B5.1 试验。本文简要介绍了 PKL 设施的特点、PKL III B5.1 试验序列以及 GINKGO 代码对 PKL III B5.1 试验的验证过程。在验证过程中,GINKGO 首先模拟稳态,然后通过设置合理的初始条件和边界条件模拟瞬态过程。然后,将热段温度、冷段温度、蒸汽发生器(SG)二次侧压力和增压器(PZR)压力等关键参数的计算结果与实验结果进行比较。通过计算结果的合理性,表明 GINKGO 能够模拟典型 SLB 事故场景中的关键现象。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
2.50
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信