Tip-apex distance as a risk factor for cut-out in cephalic double-screw nailing of intertrochanteric femur fractures.

IF 2.8 Q1 ORTHOPEDICS
Michele Coviello, Antonella Abate, Giuseppe Maccagnano, Francesco Ippolito, Vittorio Nappi, Andrea M Abbaticchio, Elio Caiaffa, Vincenzo Caiaffa
{"title":"Tip-apex distance as a risk factor for cut-out in cephalic double-screw nailing of intertrochanteric femur fractures.","authors":"Michele Coviello, Antonella Abate, Giuseppe Maccagnano, Francesco Ippolito, Vittorio Nappi, Andrea M Abbaticchio, Elio Caiaffa, Vincenzo Caiaffa","doi":"10.1302/2633-1462.56.BJO-2023-0163.R1","DOIUrl":null,"url":null,"abstract":"<p><strong>Aims: </strong>Proximal femur fractures treatment can involve anterograde nailing with a single or double cephalic screw. An undesirable failure for this fixation is screw cut-out. In a single-screw nail, a tip-apex distance (TAD) greater than 25 mm has been associated with an increased risk of cut-out. The aim of the study was to examine the role of TAD as a risk factor in a cephalic double-screw nail.</p><p><strong>Methods: </strong>A retrospective study was conducted on 112 patients treated for intertrochanteric femur fracture with a double proximal screw nail (Endovis BA2; EBA2) from January to September 2021. The analyzed variables were age, sex, BMI, comorbidities, fracture type, side, time of surgery, quality of reduction, pre-existing therapy with bisphosphonate for osteoporosis, screw placement in two different views, and TAD. The last follow-up was at 12 months. Logistic regression was used to study the potential factors of screw cut-out, and receiver operating characteristic curve to identify the threshold value.</p><p><strong>Results: </strong>A total of 98 of the 112 patients met the inclusion criteria. Overall, 65 patients were female (66.3%), the mean age was 83.23 years (SD 7.07), and the mean follow-up was 378 days (SD 36). Cut-out was observed in five patients (5.10%). The variables identified by univariate analysis with p < 0.05 were included in the multivariate logistic regression model were screw placement and TAD. The TAD was significant with an odds ratio (OR) 5.03 (p = 0.012) as the screw placement with an OR 4.35 (p = 0.043) in the anteroposterior view, and OR 10.61 (p = 0.037) in the lateral view. The TAD threshold value identified was 29.50 mm.</p><p><strong>Conclusion: </strong>Our study confirmed the risk factors for cut-out in the double-screw nail are comparable to those in the single screw. We found a TAD value of 29.50 mm to be associated with a risk of cut-out in double-screw nails, when good fracture reduction is granted. This value is higher than the one reported with single-screw nails. Therefore, we suggest the role of TAD should be reconsidered in well-reduced fractures treated with double-screw intramedullary nail.</p>","PeriodicalId":34103,"journal":{"name":"Bone & Joint Open","volume":"5 6","pages":"457-463"},"PeriodicalIF":2.8000,"publicationDate":"2024-06-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11144064/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bone & Joint Open","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1302/2633-1462.56.BJO-2023-0163.R1","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Aims: Proximal femur fractures treatment can involve anterograde nailing with a single or double cephalic screw. An undesirable failure for this fixation is screw cut-out. In a single-screw nail, a tip-apex distance (TAD) greater than 25 mm has been associated with an increased risk of cut-out. The aim of the study was to examine the role of TAD as a risk factor in a cephalic double-screw nail.

Methods: A retrospective study was conducted on 112 patients treated for intertrochanteric femur fracture with a double proximal screw nail (Endovis BA2; EBA2) from January to September 2021. The analyzed variables were age, sex, BMI, comorbidities, fracture type, side, time of surgery, quality of reduction, pre-existing therapy with bisphosphonate for osteoporosis, screw placement in two different views, and TAD. The last follow-up was at 12 months. Logistic regression was used to study the potential factors of screw cut-out, and receiver operating characteristic curve to identify the threshold value.

Results: A total of 98 of the 112 patients met the inclusion criteria. Overall, 65 patients were female (66.3%), the mean age was 83.23 years (SD 7.07), and the mean follow-up was 378 days (SD 36). Cut-out was observed in five patients (5.10%). The variables identified by univariate analysis with p < 0.05 were included in the multivariate logistic regression model were screw placement and TAD. The TAD was significant with an odds ratio (OR) 5.03 (p = 0.012) as the screw placement with an OR 4.35 (p = 0.043) in the anteroposterior view, and OR 10.61 (p = 0.037) in the lateral view. The TAD threshold value identified was 29.50 mm.

Conclusion: Our study confirmed the risk factors for cut-out in the double-screw nail are comparable to those in the single screw. We found a TAD value of 29.50 mm to be associated with a risk of cut-out in double-screw nails, when good fracture reduction is granted. This value is higher than the one reported with single-screw nails. Therefore, we suggest the role of TAD should be reconsidered in well-reduced fractures treated with double-screw intramedullary nail.

股骨转子间骨折头端双螺钉钉尖与外侧的距离是造成切口的风险因素。
目的:股骨近端骨折的治疗可采用单头螺钉或双头螺钉前行钉。这种固定方法的一个不良失败是螺钉断裂。在单螺钉钉中,顶端与外端距离(TAD)大于 25 毫米与切脱风险增加有关。本研究旨在探讨 TAD 作为头端双螺钉风险因素的作用:一项回顾性研究针对2021年1月至9月期间使用双近端螺钉(Endovis BA2; EBA2)治疗股骨转子间骨折的112例患者。分析的变量包括年龄、性别、体重指数(BMI)、合并症、骨折类型、侧位、手术时间、复位质量、是否已使用双膦酸盐治疗骨质疏松症、两种不同视角的螺钉置入方式以及 TAD。最后一次随访为 12 个月。采用逻辑回归法研究螺钉断裂的潜在因素,并通过接收者操作特征曲线确定阈值:112名患者中,共有98名符合纳入标准。总体而言,65 名患者为女性(66.3%),平均年龄为 83.23 岁(SD 7.07),平均随访时间为 378 天(SD 36)。有 5 名患者(5.10%)出现了切出现象。单变量分析确定的 P < 0.05 的变量被纳入多变量逻辑回归模型,这些变量是螺钉置入和 TAD。TAD具有重要意义,其几率比(OR)为5.03(P = 0.012),而螺钉置放的几率比(OR)在正视图中为4.35(P = 0.043),在侧视图中为10.61(P = 0.037)。确定的 TAD 临界值为 29.50 毫米:我们的研究证实了双螺钉与单螺钉发生切脱的风险因素相当。我们发现,在骨折复位良好的情况下,29.50 毫米的 TAD 值与双螺钉截断的风险相关。该值高于单螺钉钉子的报告值。因此,我们建议应重新考虑 TAD 在使用双螺旋髓内钉治疗已完全复位骨折中的作用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Bone & Joint Open
Bone & Joint Open ORTHOPEDICS-
CiteScore
5.10
自引率
0.00%
发文量
0
审稿时长
8 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信