Predicting isocitrate dehydrogenase status among adult patients with diffuse glioma using patient characteristics, radiomic features, and magnetic resonance imaging: Multi-modal analysis by variable vision transformer
IF 2.1 4区 医学Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
{"title":"Predicting isocitrate dehydrogenase status among adult patients with diffuse glioma using patient characteristics, radiomic features, and magnetic resonance imaging: Multi-modal analysis by variable vision transformer","authors":"Takuma Usuzaki , Ryusei Inamori , Takashi Shizukuishi , Yohei Morishita , Hidenobu Takagi , Mami Ishikuro , Taku Obara , Kei Takase","doi":"10.1016/j.mri.2024.05.012","DOIUrl":null,"url":null,"abstract":"<div><h3>Objectives</h3><p>To evaluate the performance of the multimodal model, termed variable Vision Transformer (vViT), in the task of predicting isocitrate dehydrogenase (IDH) status among adult patients with diffuse glioma.</p></div><div><h3>Materials and methods</h3><p>vViT was designed to predict IDH status using patient characteristics (sex and age), radiomic features, and contrast-enhanced T1-weighted images (CE-T1WI). Radiomic features were extracted from each enhancing tumor (ET), necrotic tumor core (NCR), and peritumoral edematous/infiltrated tissue (ED). CE-T1WI were split into four images and input to vViT. In the training, internal test, and external test, 271 patients with 1070 images (535 IDH wildtype, 535 IDH mutant), 35 patients with 194 images (97 IDH wildtype, 97 IDH mutant), and 291 patients with 872 images (436 IDH wildtype, 436 IDH mutant) were analyzed, respectively. Metrics including accuracy and AUC-ROC were calculated for the internal and external test datasets. Permutation importance analysis combined with the Mann–Whitney <em>U</em> test was performed to compare inputs.</p></div><div><h3>Results</h3><p>For the internal test dataset, vViT correctly predicted IDH status for all patients. For the external test dataset, an accuracy of 0.935 (95% confidence interval; 0.913–0.945) and AUC-ROC of 0.887 (0.798–0.956) were obtained. For both internal and external test datasets, CE-T1WI ET radiomic features and patient characteristics had higher importance than other inputs (<em>p</em> < 0.05).</p></div><div><h3>Conclusions</h3><p>The vViT has the potential to be a competent model in predicting IDH status among adult patients with diffuse glioma. Our results indicate that age, sex, and CE-T1WI ET radiomic features have key information in estimating IDH status.</p></div>","PeriodicalId":18165,"journal":{"name":"Magnetic resonance imaging","volume":"111 ","pages":"Pages 266-276"},"PeriodicalIF":2.1000,"publicationDate":"2024-05-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S0730725X24001620/pdfft?md5=6cb64e915f2d33c0b818d4b1e6d9d7d2&pid=1-s2.0-S0730725X24001620-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Magnetic resonance imaging","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0730725X24001620","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
Objectives
To evaluate the performance of the multimodal model, termed variable Vision Transformer (vViT), in the task of predicting isocitrate dehydrogenase (IDH) status among adult patients with diffuse glioma.
Materials and methods
vViT was designed to predict IDH status using patient characteristics (sex and age), radiomic features, and contrast-enhanced T1-weighted images (CE-T1WI). Radiomic features were extracted from each enhancing tumor (ET), necrotic tumor core (NCR), and peritumoral edematous/infiltrated tissue (ED). CE-T1WI were split into four images and input to vViT. In the training, internal test, and external test, 271 patients with 1070 images (535 IDH wildtype, 535 IDH mutant), 35 patients with 194 images (97 IDH wildtype, 97 IDH mutant), and 291 patients with 872 images (436 IDH wildtype, 436 IDH mutant) were analyzed, respectively. Metrics including accuracy and AUC-ROC were calculated for the internal and external test datasets. Permutation importance analysis combined with the Mann–Whitney U test was performed to compare inputs.
Results
For the internal test dataset, vViT correctly predicted IDH status for all patients. For the external test dataset, an accuracy of 0.935 (95% confidence interval; 0.913–0.945) and AUC-ROC of 0.887 (0.798–0.956) were obtained. For both internal and external test datasets, CE-T1WI ET radiomic features and patient characteristics had higher importance than other inputs (p < 0.05).
Conclusions
The vViT has the potential to be a competent model in predicting IDH status among adult patients with diffuse glioma. Our results indicate that age, sex, and CE-T1WI ET radiomic features have key information in estimating IDH status.
期刊介绍:
Magnetic Resonance Imaging (MRI) is the first international multidisciplinary journal encompassing physical, life, and clinical science investigations as they relate to the development and use of magnetic resonance imaging. MRI is dedicated to both basic research, technological innovation and applications, providing a single forum for communication among radiologists, physicists, chemists, biochemists, biologists, engineers, internists, pathologists, physiologists, computer scientists, and mathematicians.