Sonal Shah, Onkar H. Pirdankar, Lomesh D. Patil, Siddharth Sheth, Pooja Jain, Rahul Saradge, Smitesh Shah
{"title":"Modulation transfer function and higher order aberrations with and without corneo scleral lens in an eye with keratoconus","authors":"Sonal Shah, Onkar H. Pirdankar, Lomesh D. Patil, Siddharth Sheth, Pooja Jain, Rahul Saradge, Smitesh Shah","doi":"10.4103/jcor.jcor_114_23","DOIUrl":null,"url":null,"abstract":"The purpose is to describe image quality metrics such as modulation transfer function (MTF) and Strehl ratio and higher order aberration (HOA) with corneo scleral lens (CSL) in keratoconus. A 25-year-old male visited the outpatient department with a complaint of diminution of distance vision in the right eye. His best-corrected visual acuity was 6/60 and 6/6 partial in the right and left eyes, respectively. Slit-lamp examination revealed right eye keratoconus and left eye was Forme fruste keratoconus. There was a history of corneal collagen cross-linking with riboflavin in the right eye. The patient was dispensed with corneo-scleral contact lens and the left eye was managed with spectacle. Corneal HOA, MTF, and Strehl ratio were measured without and with CSL using iTrace aberrometer. A significant reduction in corneal HOA and improvement in image quality metrics were noted with CSL.","PeriodicalId":33073,"journal":{"name":"Journal of Clinical Ophthalmology and Research","volume":" 29","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Clinical Ophthalmology and Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/jcor.jcor_114_23","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
The purpose is to describe image quality metrics such as modulation transfer function (MTF) and Strehl ratio and higher order aberration (HOA) with corneo scleral lens (CSL) in keratoconus. A 25-year-old male visited the outpatient department with a complaint of diminution of distance vision in the right eye. His best-corrected visual acuity was 6/60 and 6/6 partial in the right and left eyes, respectively. Slit-lamp examination revealed right eye keratoconus and left eye was Forme fruste keratoconus. There was a history of corneal collagen cross-linking with riboflavin in the right eye. The patient was dispensed with corneo-scleral contact lens and the left eye was managed with spectacle. Corneal HOA, MTF, and Strehl ratio were measured without and with CSL using iTrace aberrometer. A significant reduction in corneal HOA and improvement in image quality metrics were noted with CSL.