Comparative Analysis of Cyclic Fatigue Resistance of NeoEndo Flex Vs Protaper Gold Rotary Files: An In-Vitro Study

Arun Vashisht, Nairuti Dave, Navjot Singh
{"title":"Comparative Analysis of Cyclic Fatigue Resistance of NeoEndo Flex Vs Protaper Gold Rotary Files: An In-Vitro Study","authors":"Arun Vashisht, Nairuti Dave, Navjot Singh","doi":"10.58624/svoade.2024.05.0173","DOIUrl":null,"url":null,"abstract":"Background: During the endodontic process, cleaning and shaping are essential steps. The fracture of nickel-titanium (NiTi) tools is a procedural issue that significantly impedes therapy in normal endodontic therapy. Efficient and reliable endodontic therapy requires rotary NiTi files that demonstrate superior cyclic fatigue resistance to prevent file separation within the canal. This study aimed to investigate the in-vitro cyclic fatigue resistance of two commonly used rotary NiTi files: NeoEndo Flex file and ProTaper Gold file. Methods: The cyclic fatigue tests were carried out by determining the lifespan of each file type in a controlled environment mimicking a curved root canal. A total of 30 files (15 NeoEndo Flex and 15 ProTaper Gold) were subjected to continuous rotation until fracture occurred. The numbers of cycles until failure (NCF) were recorded for statistical comparison. Results: The ProTaper Gold files showed significantly higher NCF, indicative of stronger cyclic fatigue resistance when compared to NeoEndo Flex files (p < 0.05). The variance in fatigue resistance is attributable, in part, to differences in alloy composition and proprietary heat treatment processes. Conclusion: ProTaper Gold rotary NiTi files exhibited enhanced cyclic fatigue resistance in comparison to NeoEndo Flex, suggesting that they may be the preferred choice for clinical procedures where greater stresses are anticipated on the file. However, clinicians should balance file strength with other clinical factors when choosing the appropriate file for endodontic treatment.","PeriodicalId":93501,"journal":{"name":"SVOA Dentistry","volume":" 42","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-05-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"SVOA Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.58624/svoade.2024.05.0173","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: During the endodontic process, cleaning and shaping are essential steps. The fracture of nickel-titanium (NiTi) tools is a procedural issue that significantly impedes therapy in normal endodontic therapy. Efficient and reliable endodontic therapy requires rotary NiTi files that demonstrate superior cyclic fatigue resistance to prevent file separation within the canal. This study aimed to investigate the in-vitro cyclic fatigue resistance of two commonly used rotary NiTi files: NeoEndo Flex file and ProTaper Gold file. Methods: The cyclic fatigue tests were carried out by determining the lifespan of each file type in a controlled environment mimicking a curved root canal. A total of 30 files (15 NeoEndo Flex and 15 ProTaper Gold) were subjected to continuous rotation until fracture occurred. The numbers of cycles until failure (NCF) were recorded for statistical comparison. Results: The ProTaper Gold files showed significantly higher NCF, indicative of stronger cyclic fatigue resistance when compared to NeoEndo Flex files (p < 0.05). The variance in fatigue resistance is attributable, in part, to differences in alloy composition and proprietary heat treatment processes. Conclusion: ProTaper Gold rotary NiTi files exhibited enhanced cyclic fatigue resistance in comparison to NeoEndo Flex, suggesting that they may be the preferred choice for clinical procedures where greater stresses are anticipated on the file. However, clinicians should balance file strength with other clinical factors when choosing the appropriate file for endodontic treatment.
NeoEndo Flex 与 Protaper Gold 旋转锉耐循环疲劳性的比较分析:体外研究
背景:在牙髓治疗过程中,清洁和塑形是必不可少的步骤。镍钛(NiTi)工具的断裂是一个程序问题,严重阻碍了正常的牙髓治疗。高效可靠的根管治疗需要旋转镍钛锉表现出卓越的抗循环疲劳性能,以防止锉片在根管中分离。本研究旨在调查两种常用旋转式镍钛锉的体外循环抗疲劳性:NeoEndo Flex锉和ProTaper Gold锉。方法:循环疲劳试验是在模拟弯曲根管的受控环境中测定每种锉刀的使用寿命。共对 30 支锉刀(15 支 NeoEndo Flex 和 15 支 ProTaper Gold)进行连续旋转,直至发生断裂。记录直至失效的循环次数(NCF),以便进行统计比较。结果:与NeoEndo Flex锉相比,ProTaper Gold锉的NCF明显更高,表明其具有更强的抗循环疲劳性(p < 0.05)。抗疲劳性的差异部分归因于合金成分和专有热处理工艺的不同。结论与 NeoEndo Flex 相比,ProTaper Gold 旋转镍钛锉表现出更强的抗循环疲劳性,这表明在临床手术中,如果锉上预计会有更大的应力,ProTaper Gold 旋转镍钛锉可能是首选。不过,临床医生在为牙髓治疗选择合适的锉刀时应平衡锉刀强度和其他临床因素。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信