Establishment of Typical Values for Adult Patients Undergoing Computed Tomography in Three Hospitals in Brazzaville, Congo Republic

G. B. Dallou, P. Meye, J. Bazoma, Clobithe Bouka Biona, Saïdou Saïdou, G. Ben-Bolie
{"title":"Establishment of Typical Values for Adult Patients Undergoing Computed Tomography in Three Hospitals in Brazzaville, Congo Republic","authors":"G. B. Dallou, P. Meye, J. Bazoma, Clobithe Bouka Biona, Saïdou Saïdou, G. Ben-Bolie","doi":"10.47352/jmans.2774-3047.211","DOIUrl":null,"url":null,"abstract":"The present study aimed at to establish typical dose reference level (DRL) values for adult patients undergoing computed tomography (CT) examinations in three hospitals in Brazzaville, Congo Republic. The examinations considered were head, chest, abdomen-pelvis, chest-abdomen-pelvis and lumbar spine CT scans. For each examination, the median of the distribution for the volume CT dose index (CTDIvol) and dose-length product (DLP) were determined. The median values were considered as the typical DRL values. Hypothesis testing was also carried out to statistically compare the mean values obtained for each participating CT facility. In the case of head scan, the typical values proposed in the present study in terms of CTDIvol and DLP were 15–48% and 28–60% lower than the DRL values reported in the literature, respectively. In the case of lumbar spine, the typical value determined in this study in terms of DLP was 48–70% greater than the DRL values provided in the literature. The typical values proposed for chest, abdomen-pelvis and chest-abdomen-pelvis were within the DRL values reported in the literature. It is possible that the adoption of the typical values proposed in the present study will help in reducing the dose received by adult patients undergoing CT examination in Congo Republic.","PeriodicalId":264018,"journal":{"name":"Journal of Multidisciplinary Applied Natural Science","volume":"121 35","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-05-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Multidisciplinary Applied Natural Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.47352/jmans.2774-3047.211","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The present study aimed at to establish typical dose reference level (DRL) values for adult patients undergoing computed tomography (CT) examinations in three hospitals in Brazzaville, Congo Republic. The examinations considered were head, chest, abdomen-pelvis, chest-abdomen-pelvis and lumbar spine CT scans. For each examination, the median of the distribution for the volume CT dose index (CTDIvol) and dose-length product (DLP) were determined. The median values were considered as the typical DRL values. Hypothesis testing was also carried out to statistically compare the mean values obtained for each participating CT facility. In the case of head scan, the typical values proposed in the present study in terms of CTDIvol and DLP were 15–48% and 28–60% lower than the DRL values reported in the literature, respectively. In the case of lumbar spine, the typical value determined in this study in terms of DLP was 48–70% greater than the DRL values provided in the literature. The typical values proposed for chest, abdomen-pelvis and chest-abdomen-pelvis were within the DRL values reported in the literature. It is possible that the adoption of the typical values proposed in the present study will help in reducing the dose received by adult patients undergoing CT examination in Congo Republic.
为刚果共和国布拉柴维尔三家医院接受计算机断层扫描的成人患者确定典型值
本研究旨在为在刚果共和国布拉柴维尔三家医院接受计算机断层扫描(CT)检查的成年患者确定典型的剂量参考水平(DRL)值。所考虑的检查包括头部、胸部、腹部-骨盆、胸部-腹部-骨盆和腰椎 CT 扫描。每次检查都要确定容积 CT 剂量指数(CTDIvol)和剂量-长度乘积(DLP)分布的中位数。中值被视为典型的 DRL 值。此外,还进行了假设检验,以统计比较各参与 CT 设备获得的平均值。就头部扫描而言,本研究提出的 CTDIvol 和 DLP 典型值分别比文献报道的 DRL 值低 15-48% 和 28-60%。就腰椎而言,本研究确定的 DLP 典型值比文献中提供的 DRL 值高 48-70%。胸部、腹部-骨盆和胸部-腹部-骨盆的典型值均在文献报告的 DRL 值范围内。在刚果共和国,采用本研究提出的典型值可能有助于减少接受 CT 检查的成年患者的剂量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
4.30
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信