A. Saha, N. Bodhey, Nitin Kumar Kashyap, Vinay Rathore, Rohit Badge, Jyoti Aggarwal, N. Pathak
{"title":"Tunneled Hemodialysis Catheter Making Its Way into the Spinal Canal: An Unusual Complication","authors":"A. Saha, N. Bodhey, Nitin Kumar Kashyap, Vinay Rathore, Rohit Badge, Jyoti Aggarwal, N. Pathak","doi":"10.25259/ijn_53_2024","DOIUrl":null,"url":null,"abstract":"The procedure of tunnelled hemodialysis catheter insertion is generally considered safe. We report the case of a lady who had a malpositioned femoral tunneled hemodialysis catheter that entered into the spinal canal causing neurological weakness. The catheter was later safely removed leading to partial neurological recovery.","PeriodicalId":0,"journal":{"name":"","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2024-05-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.25259/ijn_53_2024","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
The procedure of tunnelled hemodialysis catheter insertion is generally considered safe. We report the case of a lady who had a malpositioned femoral tunneled hemodialysis catheter that entered into the spinal canal causing neurological weakness. The catheter was later safely removed leading to partial neurological recovery.