Donor Site Outcomes Following Autologous Breast Reconstruction with DIEP Flap: A Retrospective and Prospective Study in a Single Institution

Pub Date : 2024-05-20 DOI:10.1177/22925503241255118
Stacy Fan, Stephanie Kim, Kaveh Farrokhi, Dianna Deng, Laryssa Laurignano, Devin Box, Aaron Grant, Sarah Appleton, Tanya DeLyzer
{"title":"Donor Site Outcomes Following Autologous Breast Reconstruction with DIEP Flap: A Retrospective and Prospective Study in a Single Institution","authors":"Stacy Fan, Stephanie Kim, Kaveh Farrokhi, Dianna Deng, Laryssa Laurignano, Devin Box, Aaron Grant, Sarah Appleton, Tanya DeLyzer","doi":"10.1177/22925503241255118","DOIUrl":null,"url":null,"abstract":"Background: The deep inferior epigastric perforator artery (DIEP) free flap is the most commonly performed autologous breast reconstruction. Despite the relative reduction in donor site complications compared to nonmuscle-sparing options, there is still high morbidity associated with this surgery. The purpose of this study is to compare outcomes and complications at our institution and to discuss potential quality improvement initiatives. Methods: A retrospective cohort study was performed looking at patients who underwent delayed or immediate autologous breast reconstruction with a DIEP flap over a 6-year period (2015-2021) at our institution. Complication rates for abdominal infection, seroma, hematoma, wound dehiscence, delayed wound healing, umbilical necrosis, subjective abdominal weakness, abdominal bulge, and hernia were calculated. Additionally, a prospective cohort study was conducted using a portable ultrasound device to detect postoperative changes in the abdominal donor site, including fluid collections and postoperative edema. Results: One hundred seventeen patients underwent autologous breast reconstruction with a DIEP-free flap. Forty-one percent of patients experienced 1 or more donor site complications. Complication rates were 16.2%, 12.8%, 1.7%, 15.4%, 8.5%, 4.3%, 0%, 10.3%, and 2.6%, respectively, for the list above. There was a higher proportion of complications in patients who smoked within the past 3 months and those who had a body mass index (BMI) between 35 and 39.9, although this was not statistically significant. Bilateral reconstructions had higher rates of umbilical necrosis (24.5% vs 7.8%) and wound dehiscence (9.4% vs 0%) compared to unilateral. Twenty-one patients were included in the prospective analysis. No significant changes in abdominal wall edema were found. Twenty-four percent of the patients had detectible collections on ultrasound, and these were associated with wound dehiscence and the need for debridement. Discussion: Our institutional abdominal donor site complication rates in DIEP reconstruction patients are higher than those published in the literature. Similar complication rates were identified regardless of smoking status, BMI, and unilateral/bilateral surgery. Quality improvement initiatives could be considered and implemented to reduce future complications.","PeriodicalId":0,"journal":{"name":"","volume":"37 22","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-05-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/22925503241255118","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: The deep inferior epigastric perforator artery (DIEP) free flap is the most commonly performed autologous breast reconstruction. Despite the relative reduction in donor site complications compared to nonmuscle-sparing options, there is still high morbidity associated with this surgery. The purpose of this study is to compare outcomes and complications at our institution and to discuss potential quality improvement initiatives. Methods: A retrospective cohort study was performed looking at patients who underwent delayed or immediate autologous breast reconstruction with a DIEP flap over a 6-year period (2015-2021) at our institution. Complication rates for abdominal infection, seroma, hematoma, wound dehiscence, delayed wound healing, umbilical necrosis, subjective abdominal weakness, abdominal bulge, and hernia were calculated. Additionally, a prospective cohort study was conducted using a portable ultrasound device to detect postoperative changes in the abdominal donor site, including fluid collections and postoperative edema. Results: One hundred seventeen patients underwent autologous breast reconstruction with a DIEP-free flap. Forty-one percent of patients experienced 1 or more donor site complications. Complication rates were 16.2%, 12.8%, 1.7%, 15.4%, 8.5%, 4.3%, 0%, 10.3%, and 2.6%, respectively, for the list above. There was a higher proportion of complications in patients who smoked within the past 3 months and those who had a body mass index (BMI) between 35 and 39.9, although this was not statistically significant. Bilateral reconstructions had higher rates of umbilical necrosis (24.5% vs 7.8%) and wound dehiscence (9.4% vs 0%) compared to unilateral. Twenty-one patients were included in the prospective analysis. No significant changes in abdominal wall edema were found. Twenty-four percent of the patients had detectible collections on ultrasound, and these were associated with wound dehiscence and the need for debridement. Discussion: Our institutional abdominal donor site complication rates in DIEP reconstruction patients are higher than those published in the literature. Similar complication rates were identified regardless of smoking status, BMI, and unilateral/bilateral surgery. Quality improvement initiatives could be considered and implemented to reduce future complications.
分享
查看原文
使用DIEP皮瓣进行自体乳房重建后的供体部位效果:单一机构的回顾性和前瞻性研究
背景:下腹穿孔动脉(DIEP)游离皮瓣是最常用的自体乳房重建术。尽管与非肌肉保留方案相比,供体部位并发症相对减少,但该手术的发病率仍然很高。本研究旨在比较本机构的治疗效果和并发症,并讨论潜在的质量改进措施。方法:我们进行了一项回顾性队列研究,调查了本院在 6 年内(2015-2021 年)使用 DIEP 皮瓣进行延迟或即刻自体乳房重建的患者。研究计算了腹部感染、血清肿、血肿、伤口裂开、伤口延迟愈合、脐部坏死、主观腹部无力、腹部隆起和疝气的并发症发生率。此外,还使用便携式超声设备进行了一项前瞻性队列研究,以检测腹部供体部位的术后变化,包括积液和术后水肿。研究结果177名患者接受了无DIEP皮瓣自体乳房重建术。41%的患者经历了一次或多次供体部位并发症。上述名单中的并发症发生率分别为 16.2%、12.8%、1.7%、15.4%、8.5%、4.3%、0%、10.3% 和 2.6%。过去3个月内吸烟的患者和体重指数(BMI)在35-39.9之间的患者出现并发症的比例较高,但没有统计学意义。与单侧重建相比,双侧重建的脐坏死率(24.5% 对 7.8%)和伤口裂开率(9.4% 对 0%)更高。21 名患者被纳入前瞻性分析。未发现腹壁水肿有明显变化。24%的患者在超声波检查中发现了积液,这些积液与伤口开裂和需要清创有关。讨论:我们机构的 DIEP 重建患者腹部供体部位并发症发生率高于文献发表的发生率。无论吸烟状况、体重指数和单侧/双侧手术情况如何,并发症发生率相似。可以考虑并实施质量改进措施,以减少未来的并发症。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信