Michael Unger, Annika Hänel, Claire Chalopin, Dirk Halama
{"title":"Design and evaluation of an AR-based thermal imaging system for planning reconstructive surgeries.","authors":"Michael Unger, Annika Hänel, Claire Chalopin, Dirk Halama","doi":"10.1007/s11548-024-03184-1","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Thermal imaging can be used for the non-invasive detection of blood vessels of the skin. However, mapping the results to the patient currently lacks user-friendliness. Augmented reality may provide a useful tool to superimpose thermal information on the patient.</p><p><strong>Methods: </strong>A system to support planning in reconstructive surgery using a thermal camera was designed. The obtained information was superimposed on the physical object using a Microsoft HoloLens. An RGB, depth, and thermal camera were combined to capture a scene of different modalities and reconstruct a virtual scene in real time. To register the different cameras and the AR device, an active calibration target was developed and evaluated. A Vuforia marker was used to register the hologram in the virtual space. The accuracy of the projected hologram was evaluated in a laboratory setting with participants by measuring the error between the physical object and the hologram.</p><p><strong>Results: </strong>The AR-based system was evaluated by 21 participants in a laboratory setting. The mean projection error is 10.3 ± 9.4 mm. The system is able to stream a three-dimensional scene with augmented thermal information in real time at 5 frames per second. The active calibration target can be used independently of the environment.</p><p><strong>Conclusion: </strong>The calibration target provides an easy-to-use method for the registration of cameras capturing the visible to long-infrared spectral range. The inside-out tracking of the HoloLens in combination with a Vuforia marker is not accurate enough for the intended clinical use.</p>","PeriodicalId":51251,"journal":{"name":"International Journal of Computer Assisted Radiology and Surgery","volume":" ","pages":"1659-1666"},"PeriodicalIF":2.3000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Computer Assisted Radiology and Surgery","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s11548-024-03184-1","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/5/24 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction: Thermal imaging can be used for the non-invasive detection of blood vessels of the skin. However, mapping the results to the patient currently lacks user-friendliness. Augmented reality may provide a useful tool to superimpose thermal information on the patient.
Methods: A system to support planning in reconstructive surgery using a thermal camera was designed. The obtained information was superimposed on the physical object using a Microsoft HoloLens. An RGB, depth, and thermal camera were combined to capture a scene of different modalities and reconstruct a virtual scene in real time. To register the different cameras and the AR device, an active calibration target was developed and evaluated. A Vuforia marker was used to register the hologram in the virtual space. The accuracy of the projected hologram was evaluated in a laboratory setting with participants by measuring the error between the physical object and the hologram.
Results: The AR-based system was evaluated by 21 participants in a laboratory setting. The mean projection error is 10.3 ± 9.4 mm. The system is able to stream a three-dimensional scene with augmented thermal information in real time at 5 frames per second. The active calibration target can be used independently of the environment.
Conclusion: The calibration target provides an easy-to-use method for the registration of cameras capturing the visible to long-infrared spectral range. The inside-out tracking of the HoloLens in combination with a Vuforia marker is not accurate enough for the intended clinical use.