Biocompatibility profile of aged pigmented and non-pigmented silicone elastomer for combined maxillofacial defects.

IF 3.4 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE
Eman M Saleh, Faten S Mohamed, Radwa A Mehanna, Marwa M Essawy, Ingy S Soliman
{"title":"Biocompatibility profile of aged pigmented and non-pigmented silicone elastomer for combined maxillofacial defects.","authors":"Eman M Saleh, Faten S Mohamed, Radwa A Mehanna, Marwa M Essawy, Ingy S Soliman","doi":"10.1111/jopr.13873","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To assess the biocompatibility of platinum silicone elastomer A-2000 used in combined maxillofacial defects prosthesis, after being deteriorated by an accelerated aging process resembling both the extra and intraoral environment. This assessment was done indirectly on human-derived dermal and gingival tissues.</p><p><strong>Materials and methods: </strong>One hundred eight samples of room-temperature vulcanized A-2000 platinum silicone were equally divided into extrinsically pigmented and non-pigmented groups to replicate combined maxillofacial defects. Accelerated aging was applied to pigmented samples to mimic extra- and intra-oral conditions, while non-aged counterparts served as controls. After isolating human cell lineages, dermal and gingival fibroblasts were indirectly exposed to silicone sample media. Cytotoxicity to cultured fibroblasts was assessed via MTT assay. Statistical significance was determined by repeated measures of one-way ANOVA (p < 0.01), evaluating cytotoxicity on dermal and gingival fibroblasts.</p><p><strong>Results: </strong>MTT assay showed increased cytotoxicity in pigmented silicon samples subjected to extraoral aging compared to non-aged counterparts (p < 0.01). Non-pigmented silicon, modeling intraoral conditions, exhibited cytotoxicity after 48 h (p < 0.05). Both aged and non-aged silicon extracts equally sensitized gingival fibroblasts at 72 h (p < 0.001). Negative correlations between pigmented and non-pigmented silicon were observed in dermal cell growth (p > 0.05, except at 24 h, r = 0.2), with accelerated aging showing minimal impact on the pigmentation effect (p > 0.05).</p><p><strong>Conclusion: </strong>The retrieved diminished cellular metabolic activity of platinum silicone elastomer was in an acceptable clinical range, pointing out the importance of periodic assessments of the maxillofacial prosthesis for replacement depending on aging and cytotoxic harmful cellular responses.</p>","PeriodicalId":49152,"journal":{"name":"Journal of Prosthodontics-Implant Esthetic and Reconstructive Dentistry","volume":null,"pages":null},"PeriodicalIF":3.4000,"publicationDate":"2024-05-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Prosthodontics-Implant Esthetic and Reconstructive Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/jopr.13873","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To assess the biocompatibility of platinum silicone elastomer A-2000 used in combined maxillofacial defects prosthesis, after being deteriorated by an accelerated aging process resembling both the extra and intraoral environment. This assessment was done indirectly on human-derived dermal and gingival tissues.

Materials and methods: One hundred eight samples of room-temperature vulcanized A-2000 platinum silicone were equally divided into extrinsically pigmented and non-pigmented groups to replicate combined maxillofacial defects. Accelerated aging was applied to pigmented samples to mimic extra- and intra-oral conditions, while non-aged counterparts served as controls. After isolating human cell lineages, dermal and gingival fibroblasts were indirectly exposed to silicone sample media. Cytotoxicity to cultured fibroblasts was assessed via MTT assay. Statistical significance was determined by repeated measures of one-way ANOVA (p < 0.01), evaluating cytotoxicity on dermal and gingival fibroblasts.

Results: MTT assay showed increased cytotoxicity in pigmented silicon samples subjected to extraoral aging compared to non-aged counterparts (p < 0.01). Non-pigmented silicon, modeling intraoral conditions, exhibited cytotoxicity after 48 h (p < 0.05). Both aged and non-aged silicon extracts equally sensitized gingival fibroblasts at 72 h (p < 0.001). Negative correlations between pigmented and non-pigmented silicon were observed in dermal cell growth (p > 0.05, except at 24 h, r = 0.2), with accelerated aging showing minimal impact on the pigmentation effect (p > 0.05).

Conclusion: The retrieved diminished cellular metabolic activity of platinum silicone elastomer was in an acceptable clinical range, pointing out the importance of periodic assessments of the maxillofacial prosthesis for replacement depending on aging and cytotoxic harmful cellular responses.

用于合并颌面部缺损的老化色素和非色素硅树脂弹性体的生物相容性概况。
目的:评估用于颌面缺损联合修复体的铂硅树脂弹性体 A-2000 在经过类似口内外环境的加速老化过程后的生物相容性。这项评估是在源自人体的真皮和牙龈组织上间接完成的:将 18 个室温硫化的 A-2000 铂金硅胶样品平均分为口外色素沉着组和非色素沉着组,以复制合并的颌面部缺损。对色素样本进行加速老化,以模拟口外和口内情况,而未老化的样本则作为对照组。分离人体细胞系后,将真皮和牙龈成纤维细胞间接暴露于硅胶样本培养基中。培养成纤维细胞的细胞毒性通过 MTT 试验进行评估。在评估对皮肤和牙龈成纤维细胞的细胞毒性时,采用单因素方差分析的重复测量法(p < 0.01)确定统计意义:MTT检测显示,与未老化的样品相比,经过口外老化的色素硅样品的细胞毒性增加(p < 0.01)。口内条件下的非色素硅在 48 小时后显示出细胞毒性(p < 0.05)。72 小时后,老化和非老化硅提取物对牙龈成纤维细胞同样具有敏化作用(p < 0.001)。色素硅和非色素硅在真皮细胞生长中呈负相关(p > 0.05,24 小时除外,r = 0.2),加速老化对色素沉着效果的影响极小(p > 0.05):结论:铂硅弹性体细胞代谢活性的降低处于临床可接受的范围内,这表明定期评估颌面假体的重要性,以便根据老化和有害细胞的细胞毒性反应进行更换。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
7.90
自引率
15.00%
发文量
171
审稿时长
6-12 weeks
期刊介绍: The Journal of Prosthodontics promotes the advanced study and practice of prosthodontics, implant, esthetic, and reconstructive dentistry. It is the official journal of the American College of Prosthodontists, the American Dental Association-recognized voice of the Specialty of Prosthodontics. The journal publishes evidence-based original scientific articles presenting information that is relevant and useful to prosthodontists. Additionally, it publishes reports of innovative techniques, new instructional methodologies, and instructive clinical reports with an interdisciplinary flair. The journal is particularly focused on promoting the study and use of cutting-edge technology and positioning prosthodontists as the early-adopters of new technology in the dental community.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信