Noise-based correction for electrical impedance tomography.

IF 2.3 4区 医学 Q3 BIOPHYSICS
Kai Mason, Florencia Maurino-Alperovich, David Holder, Kirill Aristovich
{"title":"Noise-based correction for electrical impedance tomography.","authors":"Kai Mason, Florencia Maurino-Alperovich, David Holder, Kirill Aristovich","doi":"10.1088/1361-6579/ad4e93","DOIUrl":null,"url":null,"abstract":"<p><p><i>Objective.</i>Noisy measurements frequently cause noisy and inaccurate images in impedance imaging. No post-processing technique exists to calculate the propagation of measurement noise and use this to suppress noise in the image. The objectives of this work were (1) to develop a post-processing method for noise-based correction (NBC) in impedance tomography, (2) to test whether NBC improves image quality in electrical impedance tomography (EIT), (3) to determine whether it is preferable to use correlated or uncorrelated noise for NBC, (4) to test whether NBC works with<i>in vivo</i>data and (5) to test whether NBC is stable across model and perturbation geometries.<i>Approach.</i>EIT was performed<i>in silico</i>in a 2D homogeneous circular domain and an anatomically realistic, heterogeneous 3D human head domain for four perturbations and 25 noise levels in each case. This was validated by performing EIT for four perturbations in a circular, saline tank in 2D as well as a human head-shaped saline tank with a realistic skull-like layer in 3D. Images were assessed on the error in the weighted spatial variance (WSV) with respect to the true, target image. The effect of NBC was also tested for<i>in vivo</i>EIT data of lung ventilation in a human thorax and cortical activity in a rat brain.<i>Main results.</i>On visual inspection, NBC maintained or increased image quality for all perturbations and noise levels in 2D and 3D, both experimentally and<i>in silico</i>. Analysis of the WSV showed that NBC significantly improved the WSV in nearly all cases. When the WSV was inferior with NBC, this was either visually imperceptible or a transformation between noisy reconstructions. For<i>in vivo</i>data, NBC improved image quality in all cases and preserved the expected shape of the reconstructed perturbation.<i>Significance.</i>In practice, uncorrelated NBC performed better than correlated NBC and is recommended as a general-use post-processing technique in EIT.</p>","PeriodicalId":20047,"journal":{"name":"Physiological measurement","volume":null,"pages":null},"PeriodicalIF":2.3000,"publicationDate":"2024-06-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physiological measurement","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1088/1361-6579/ad4e93","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"BIOPHYSICS","Score":null,"Total":0}
引用次数: 0

Abstract

Objective.Noisy measurements frequently cause noisy and inaccurate images in impedance imaging. No post-processing technique exists to calculate the propagation of measurement noise and use this to suppress noise in the image. The objectives of this work were (1) to develop a post-processing method for noise-based correction (NBC) in impedance tomography, (2) to test whether NBC improves image quality in electrical impedance tomography (EIT), (3) to determine whether it is preferable to use correlated or uncorrelated noise for NBC, (4) to test whether NBC works within vivodata and (5) to test whether NBC is stable across model and perturbation geometries.Approach.EIT was performedin silicoin a 2D homogeneous circular domain and an anatomically realistic, heterogeneous 3D human head domain for four perturbations and 25 noise levels in each case. This was validated by performing EIT for four perturbations in a circular, saline tank in 2D as well as a human head-shaped saline tank with a realistic skull-like layer in 3D. Images were assessed on the error in the weighted spatial variance (WSV) with respect to the true, target image. The effect of NBC was also tested forin vivoEIT data of lung ventilation in a human thorax and cortical activity in a rat brain.Main results.On visual inspection, NBC maintained or increased image quality for all perturbations and noise levels in 2D and 3D, both experimentally andin silico. Analysis of the WSV showed that NBC significantly improved the WSV in nearly all cases. When the WSV was inferior with NBC, this was either visually imperceptible or a transformation between noisy reconstructions. Forin vivodata, NBC improved image quality in all cases and preserved the expected shape of the reconstructed perturbation.Significance.In practice, uncorrelated NBC performed better than correlated NBC and is recommended as a general-use post-processing technique in EIT.

基于噪声的电阻抗断层扫描校正。
简介在阻抗成像中,噪声测量经常会造成噪声和不准确的图像。目前还没有一种后处理技术可以计算测量噪声的传播,并以此来抑制图像中的噪声:目标:(1) 在阻抗断层成像中开发一种基于噪声校正(NBC)的后处理方法;(2) 测试 NBC 是否能改善电阻抗断层成像(EIT)的图像质量;(3) 确定在 NBC 中使用相关噪声还是非相关噪声更可取;(4) 测试 NBC 是否能改善活体数据的图像质量;(5) 测试 NBC 在不同模型和扰动几何中是否稳定:在二维同质圆形域和现实的异质三维人体头部域中,针对四种扰动和 25 种噪声水平进行了模拟 EIT。在二维的圆形生理盐水箱和三维的人头形生理盐水箱中,对四种扰动和 25 种噪声水平进行了 EIT 验证。根据相对于真实目标图像的加权空间方差(WSV)对图像进行评估。还测试了 NBC 对人体胸部肺通气和大鼠大脑皮层活动的活体 EIT 数据的影响:肉眼观察,无论是在实验中还是在硅学中,对于二维和三维的所有扰动和噪声水平,NBC 都能保持或提高图像质量。对 WSV 的分析表明,几乎在所有情况下,NBC 都能显著改善 WSV。当 NBC 使 WSV 变差时,要么是视觉上无法察觉,要么是噪声重建之间的转换。对于活体数据,NBC 在所有情况下都能改善图像质量,并保持重建扰动的预期形状。在实践中,非相关 NBC 比相关 NBC 效果更好,建议将其作为 EIT 的通用后处理技术。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Physiological measurement
Physiological measurement 生物-工程:生物医学
CiteScore
5.50
自引率
9.40%
发文量
124
审稿时长
3 months
期刊介绍: Physiological Measurement publishes papers about the quantitative assessment and visualization of physiological function in clinical research and practice, with an emphasis on the development of new methods of measurement and their validation. Papers are published on topics including: applied physiology in illness and health electrical bioimpedance, optical and acoustic measurement techniques advanced methods of time series and other data analysis biomedical and clinical engineering in-patient and ambulatory monitoring point-of-care technologies novel clinical measurements of cardiovascular, neurological, and musculoskeletal systems. measurements in molecular, cellular and organ physiology and electrophysiology physiological modeling and simulation novel biomedical sensors, instruments, devices and systems measurement standards and guidelines.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信