Analysing Pre-Operative Gait Patterns Using Inertial Wearable Sensors: An Observational Study of Participants Undergoing Total Hip and Knee Replacement

IF 0.1 Q4 SURGERY
Egidio Riggio, Federico Canavese, Pragadesh Natarajan, A. Lim, Cha Yin, R. D. Fonseka, David Abi-Hanna, Kaitlin Rooke, L. Sy, Monish M. Maharaj, David Broe, Lianne Koinis, R. Mobbs
{"title":"Analysing Pre-Operative Gait Patterns Using Inertial Wearable Sensors: An Observational Study of Participants Undergoing Total Hip and Knee Replacement","authors":"Egidio Riggio, Federico Canavese, Pragadesh Natarajan, A. Lim, Cha Yin, R. D. Fonseka, David Abi-Hanna, Kaitlin Rooke, L. Sy, Monish M. Maharaj, David Broe, Lianne Koinis, R. Mobbs","doi":"10.3390/std13020011","DOIUrl":null,"url":null,"abstract":"Background. Knee and hip arthroplasty are two of the most frequently performed procedures in orthopaedic surgery. They are associated with positive patient-reported outcomes and significant improvements in quality of life for patients. Despite this, there may be room for further progress by quantifying functional improvements with gait analysis. Our study therefore aims to characterise the disease-specific gait pattern of participants with knee and hip osteoarthritis undergoing total joint replacement using a single chest-based wearable sensor. Methods. Twenty-nine participants awaiting total hip replacement and 28 participants awaiting total knee replacement underwent three-dimensional motion analysis with inertial wearable sensors. These gait metrics were then compared with 28 healthy controls of similar ages. Differences in gait metrics were evaluated using a T-test. The participants were recruited through a single centre to participate in this cross-sectional observational study. Participants with osteoarthritis severity sufficient to warrant surgical intervention were considered for inclusion in our study. The participants were instructed to walk 15–120 m in a hospital environment while fitted with a chest-based wearable sensor. Results. In total, three domains were evaluated, including spatiotemporal, variability and asymmetry parameters. There were marked variations in the gait asymmetry parameters and step length variation in both the hip and knee osteoarthritis patients compared with the healthy controls. The magnitude of gait deterioration in terms of step length asymmetry was greater on average in the hip osteoarthritis group than the knee group. The hip osteoarthritis (+180%, p < 0.001) and knee osteoarthritis (+129%, p = 0.001) groups demonstrated marked differences in step length asymmetry. Discussion. A single chest-based sensor was found to be capable of detecting pathological gait signatures in osteoarthritis patients when compared with age-matched controls. Future studies should compare pre- and postoperative changes to disease-specific gait impairments to validate the use of wearable sensors as a clinical adjunct.","PeriodicalId":40379,"journal":{"name":"Surgical Techniques Development","volume":null,"pages":null},"PeriodicalIF":0.1000,"publicationDate":"2024-05-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Surgical Techniques Development","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/std13020011","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

Abstract

Background. Knee and hip arthroplasty are two of the most frequently performed procedures in orthopaedic surgery. They are associated with positive patient-reported outcomes and significant improvements in quality of life for patients. Despite this, there may be room for further progress by quantifying functional improvements with gait analysis. Our study therefore aims to characterise the disease-specific gait pattern of participants with knee and hip osteoarthritis undergoing total joint replacement using a single chest-based wearable sensor. Methods. Twenty-nine participants awaiting total hip replacement and 28 participants awaiting total knee replacement underwent three-dimensional motion analysis with inertial wearable sensors. These gait metrics were then compared with 28 healthy controls of similar ages. Differences in gait metrics were evaluated using a T-test. The participants were recruited through a single centre to participate in this cross-sectional observational study. Participants with osteoarthritis severity sufficient to warrant surgical intervention were considered for inclusion in our study. The participants were instructed to walk 15–120 m in a hospital environment while fitted with a chest-based wearable sensor. Results. In total, three domains were evaluated, including spatiotemporal, variability and asymmetry parameters. There were marked variations in the gait asymmetry parameters and step length variation in both the hip and knee osteoarthritis patients compared with the healthy controls. The magnitude of gait deterioration in terms of step length asymmetry was greater on average in the hip osteoarthritis group than the knee group. The hip osteoarthritis (+180%, p < 0.001) and knee osteoarthritis (+129%, p = 0.001) groups demonstrated marked differences in step length asymmetry. Discussion. A single chest-based sensor was found to be capable of detecting pathological gait signatures in osteoarthritis patients when compared with age-matched controls. Future studies should compare pre- and postoperative changes to disease-specific gait impairments to validate the use of wearable sensors as a clinical adjunct.
使用惯性可穿戴传感器分析术前步态:对接受全髋关节和膝关节置换术者的观察研究
背景。膝关节和髋关节置换术是骨科手术中最常见的两种手术。它们与患者报告的积极疗效和患者生活质量的显著改善有关。尽管如此,通过步态分析量化功能改善情况仍有进一步提高的空间。因此,我们的研究旨在使用单个胸前可穿戴传感器,分析接受全关节置换术的膝关节和髋关节骨关节炎患者的特定疾病步态特征。研究方法29 名等待进行全髋关节置换术的患者和 28 名等待进行全膝关节置换术的患者使用惯性可穿戴传感器进行了三维运动分析。然后将这些步态指标与 28 名年龄相仿的健康对照者进行比较。步态指标的差异采用 T 检验法进行评估。这项横断面观察性研究通过一个中心招募参与者。我们考虑将骨关节炎严重到需要手术治疗的参与者纳入研究范围。研究人员要求参与者在医院环境中步行 15-120 米,同时在胸前佩戴可穿戴传感器。研究结果总共评估了三个领域,包括时空参数、变异性参数和不对称参数。与健康对照组相比,髋关节和膝关节骨性关节炎患者的步态不对称参数和步长变化都有明显差异。就步长不对称而言,髋关节骨关节炎组的步态退化程度平均大于膝关节骨关节炎组。髋关节骨关节炎组(+180%,p < 0.001)和膝关节骨关节炎组(+129%,p = 0.001)在步长不对称方面表现出明显差异。讨论与年龄匹配的对照组相比,发现单个胸部传感器能够检测骨关节炎患者的病态步态特征。未来的研究应比较术前和术后特定疾病步态障碍的变化,以验证可穿戴传感器作为临床辅助工具的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
10
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信