Failure rate of infra-zygomatic crest (IZC) bone screws in orthodontics: A Systematic review

H. Nandan, Srinivas Gosla Reddy, A. Chug, Ashutosh Dixit, Pragjyoti Jha
{"title":"Failure rate of infra-zygomatic crest (IZC) bone screws in orthodontics: A Systematic review","authors":"H. Nandan, Srinivas Gosla Reddy, A. Chug, Ashutosh Dixit, Pragjyoti Jha","doi":"10.18231/j.jco.2024.019","DOIUrl":null,"url":null,"abstract":"The aim of this review is to provide a precise estimation of infra-zygomatic crest (IZC) bone screw failure rate during orthodontic treatment. Data were obtained using the Cochrane Central Register of Controlled Trails (central), PUBMED, EMBASE, google scholar, OVID, Wiley library till 1 January 2022. The titles and abstract of the electronic search were screened and evaluated by two observers according to the inclusion and exclusion criteria. This review was enrolled in PROSPERO (registration ID number CRD42020206610). There were 1725 records identified through electronic and 1 additional record identified through manual search. After 377 duplicate removal, 1349 studies were screened on the base of title and abstract the final sample included 9 studies that meet the primary inclusion criteria were selected. Each study was assessed using the evaluation method described in the Cochrane handbook for systematic reviews. All studier collectively included of the 1238 IZC miniscrews. Included studies ranged from 20 to 772 IZC miniscrews and the average number was approximate 137 IZC miniscrews per study. The diameter of inserted IZC miniscrews ranged from 1.2 to 2.3 mm and length ranged from 6 to 17 mm. The recorded failure rate ranged from 0% to 47.2%, and the average failure rate for IZC miniscrew was 9.45% (with 95% CI [58.91; 93.82]).IZC miniscrew has low failure rate which suggest that IZC miniscrew are clinically reliable. Miniscrew are a stable anchorage for orthodontic tooth movement and zygomatic buttress of maxilla is suitable region for skeletal anchorage device placement.","PeriodicalId":497876,"journal":{"name":"Journal of Contemporary Orthodontics","volume":"19 9","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-05-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Contemporary Orthodontics","FirstCategoryId":"0","ListUrlMain":"https://doi.org/10.18231/j.jco.2024.019","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The aim of this review is to provide a precise estimation of infra-zygomatic crest (IZC) bone screw failure rate during orthodontic treatment. Data were obtained using the Cochrane Central Register of Controlled Trails (central), PUBMED, EMBASE, google scholar, OVID, Wiley library till 1 January 2022. The titles and abstract of the electronic search were screened and evaluated by two observers according to the inclusion and exclusion criteria. This review was enrolled in PROSPERO (registration ID number CRD42020206610). There were 1725 records identified through electronic and 1 additional record identified through manual search. After 377 duplicate removal, 1349 studies were screened on the base of title and abstract the final sample included 9 studies that meet the primary inclusion criteria were selected. Each study was assessed using the evaluation method described in the Cochrane handbook for systematic reviews. All studier collectively included of the 1238 IZC miniscrews. Included studies ranged from 20 to 772 IZC miniscrews and the average number was approximate 137 IZC miniscrews per study. The diameter of inserted IZC miniscrews ranged from 1.2 to 2.3 mm and length ranged from 6 to 17 mm. The recorded failure rate ranged from 0% to 47.2%, and the average failure rate for IZC miniscrew was 9.45% (with 95% CI [58.91; 93.82]).IZC miniscrew has low failure rate which suggest that IZC miniscrew are clinically reliable. Miniscrew are a stable anchorage for orthodontic tooth movement and zygomatic buttress of maxilla is suitable region for skeletal anchorage device placement.
颧骨下(IZC)骨螺钉在正畸中的失败率:系统回顾
本综述旨在精确估算正畸治疗期间颧骨下嵴(IZC)骨螺钉的失败率。数据通过 Cochrane Central Register of Controlled Trails(中央对照登记)、PUBMED、EMBASE、google scholar、OVID 和 Wiley 图书馆获取,截止日期为 2022 年 1 月 1 日。由两名观察员根据纳入和排除标准对电子检索的标题和摘要进行筛选和评估。本综述被纳入 PROSPERO(注册编号为 CRD42020206610)。通过电子检索确定了 1725 条记录,通过人工检索又确定了 1 条记录。在去除 377 条重复记录后,根据标题和摘要筛选出 1349 项研究,最终选出 9 项符合主要纳入标准的研究。我们采用 Cochrane 系统综述手册中描述的评估方法对每项研究进行了评估。所有研究者共纳入了 1238 个 IZC 微型螺钉。纳入的研究从 20 到 772 个 IZC 迷你螺钉不等,平均每个研究约有 137 个 IZC 迷你螺钉。插入的 IZC 迷你螺钉直径从 1.2 毫米到 2.3 毫米不等,长度从 6 毫米到 17 毫米不等。记录的失败率从 0% 到 47.2% 不等,IZC 迷你螺钉的平均失败率为 9.45%(95% CI [58.91; 93.82])。IZC微型螺钉的失败率较低,这表明IZC微型螺钉在临床上是可靠的。微型螺钉是牙齿正畸移动的稳定锚定装置,而上颌骨的颧骨是适合放置骨骼锚定装置的区域。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信