Comparation between Fibroscan and Hepatus for detecting NAFLD in patients with metabolic dysregulation

Jie Sun, Ping-ping Zhang, Kun Wang, Miao Xu, Jing Sun, Li Li
{"title":"Comparation between Fibroscan and Hepatus for detecting NAFLD in patients with metabolic dysregulation","authors":"Jie Sun, Ping-ping Zhang, Kun Wang, Miao Xu, Jing Sun, Li Li","doi":"10.24871/251202411-20","DOIUrl":null,"url":null,"abstract":"Background The clinical application of the innovative instantaneous elasticity and fat attenuation measurement technology, Hepatus, is currently in the evaluation stage. This study aimed to compare the detection performance of Fibroscan and Hepatus in patients with metabolic dysregulation who are \"at-risk\" for non-alcoholic fatty liver disease (NAFLD).Methods Between January 2021 and April 2021, 149 patients were enrolled in this study. Clinical data were collected, and all patients underwent both Fibroscan and Hepatus assessments to determine liver stiffness measurement (LSM) and attenuation parameters. The correlation between the results obtained from the two transient elastography (TE) devices was analyzed. Receiver operating characteristic curves (ROC) were constructed to compare the diagnostic value of Fibroscan and Hepatus for Hepatic Steatosis Index (HSI)-based NAFLD.Results The detection success rate of Hepatus (100.0%) was higher than that of Fibroscan (96.0%). LSM (r = 0.663, P0.05) and attenuation parameters (r = 0.778, P0.05) obtained by Fibroscan and Hepatus were significantly correlated. Hepatus tended to produce a higher LSM (Hepatus vs. Fibroscan: 6.04 vs. 5.66 kPa, P=0.016) but a lower attenuation parameter than Fibroscan (Hepatus vs. Fibroscan: 264 vs. 277 dB/m, P0.001). The area under the ROC curve for detecting HSI-based NAFLD was 0.811 for Fibroscan and 0.832 for Hepatus.Conclusion Measurements obtained by Fibroscan and Hepatus are strongly correlated, and the diagnostic value of the two TE devices is comparable in detecting HSI-based NAFLD. Hepatus offer a potential TE alternative in NAFLD examination.","PeriodicalId":515400,"journal":{"name":"The Indonesian Journal of Gastroenterology, Hepatology, and Digestive Endoscopy","volume":"28 3","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-05-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Indonesian Journal of Gastroenterology, Hepatology, and Digestive Endoscopy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24871/251202411-20","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background The clinical application of the innovative instantaneous elasticity and fat attenuation measurement technology, Hepatus, is currently in the evaluation stage. This study aimed to compare the detection performance of Fibroscan and Hepatus in patients with metabolic dysregulation who are "at-risk" for non-alcoholic fatty liver disease (NAFLD).Methods Between January 2021 and April 2021, 149 patients were enrolled in this study. Clinical data were collected, and all patients underwent both Fibroscan and Hepatus assessments to determine liver stiffness measurement (LSM) and attenuation parameters. The correlation between the results obtained from the two transient elastography (TE) devices was analyzed. Receiver operating characteristic curves (ROC) were constructed to compare the diagnostic value of Fibroscan and Hepatus for Hepatic Steatosis Index (HSI)-based NAFLD.Results The detection success rate of Hepatus (100.0%) was higher than that of Fibroscan (96.0%). LSM (r = 0.663, P0.05) and attenuation parameters (r = 0.778, P0.05) obtained by Fibroscan and Hepatus were significantly correlated. Hepatus tended to produce a higher LSM (Hepatus vs. Fibroscan: 6.04 vs. 5.66 kPa, P=0.016) but a lower attenuation parameter than Fibroscan (Hepatus vs. Fibroscan: 264 vs. 277 dB/m, P0.001). The area under the ROC curve for detecting HSI-based NAFLD was 0.811 for Fibroscan and 0.832 for Hepatus.Conclusion Measurements obtained by Fibroscan and Hepatus are strongly correlated, and the diagnostic value of the two TE devices is comparable in detecting HSI-based NAFLD. Hepatus offer a potential TE alternative in NAFLD examination.
Fibroscan 和 Hepatus 在检测代谢失调患者非酒精性脂肪肝方面的比较
背景 创新性瞬时弹性和脂肪衰减测量技术 Hepatus 的临床应用目前正处于评估阶段。本研究旨在比较 Fibroscan 和 Hepatus 对代谢失调的非酒精性脂肪肝(NAFLD)"高危 "患者的检测性能。收集了临床数据,所有患者都接受了 Fibroscan 和 Hepatus 评估,以确定肝脏硬度测量(LSM)和衰减参数。研究分析了两种瞬态弹性成像(TE)设备得出的结果之间的相关性。结果 Hepatus 的检测成功率(100.0%)高于 Fibroscan(96.0%)。Fibroscan和Hepatus获得的LSM(r = 0.663,P0.05)和衰减参数(r = 0.778,P0.05)显著相关。Hepatus 产生的 LSM 往往比 Fibroscan 高(Hepatus vs. Fibroscan:6.04 vs. 5.66 kPa,P=0.016),但衰减参数比 Fibroscan 低(Hepatus vs. Fibroscan:264 vs. 277 dB/m,P0.001)。结论 Fibroscan 和 Hepatus 的测量结果具有很强的相关性,两种 TE 设备在检测基于 HSI 的 NAFLD 方面的诊断价值相当。Hepatus为非酒精性脂肪肝检查提供了一种潜在的TE替代方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信