Peripheral air jet injection at part load operation of a low head Francis turbine

SANDEEP KUMAR, BHUPENDRA K GANDHI
{"title":"Peripheral air jet injection at part load operation of a low head Francis turbine","authors":"SANDEEP KUMAR, BHUPENDRA K GANDHI","doi":"10.1007/s12046-024-02524-w","DOIUrl":null,"url":null,"abstract":"<p>The rotating vortex rope in the flow field generates low-frequency, high-amplitude pulsations at part load (PL) operation of a Francis turbine. These high amplitude pressure pulsations are responsible for power swing, cyclic fatigue, heavy structural vibrations, draft tube surge, and mechanical failure of turbine components. The fluid injection methods are generally employed to arrest or mitigate these low frequencies pressure pulsations. In the present work, the air is injected at a rate of 0.5% to 2.5% of the turbine flow rate at PL. The draft tube (DT) cone is modified to accommodate the air injection mechanism. Spectral analysis and spatial harmonic decomposition (SHD) are performed on pressure data for detailed investigation. The SHD is performed to get the synchronous (plunging component) and asynchronous fluctuations (rotating component) of pressure pulsations in the DT cone. The air injection in the DT cone successfully arrested the low-frequency pulsations of high amplitudes.</p>","PeriodicalId":21498,"journal":{"name":"Sādhanā","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-05-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sādhanā","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s12046-024-02524-w","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The rotating vortex rope in the flow field generates low-frequency, high-amplitude pulsations at part load (PL) operation of a Francis turbine. These high amplitude pressure pulsations are responsible for power swing, cyclic fatigue, heavy structural vibrations, draft tube surge, and mechanical failure of turbine components. The fluid injection methods are generally employed to arrest or mitigate these low frequencies pressure pulsations. In the present work, the air is injected at a rate of 0.5% to 2.5% of the turbine flow rate at PL. The draft tube (DT) cone is modified to accommodate the air injection mechanism. Spectral analysis and spatial harmonic decomposition (SHD) are performed on pressure data for detailed investigation. The SHD is performed to get the synchronous (plunging component) and asynchronous fluctuations (rotating component) of pressure pulsations in the DT cone. The air injection in the DT cone successfully arrested the low-frequency pulsations of high amplitudes.

Abstract Image

低水头混流式水轮机部分负荷运行时的外围空气喷射
混流式水轮机在部分负荷(PL)运行时,流场中的旋转涡绳会产生低频、高振幅脉动。这些高振幅压力脉动会导致功率波动、周期性疲劳、严重的结构振动、牵伸管激增以及水轮机部件的机械故障。通常采用注入流体的方法来抑制或减轻这些低频压力脉动。在本研究中,空气注入量为 PL 处涡轮流量的 0.5% 至 2.5%。为适应空气喷射机制,对通风管(DT)锥体进行了修改。为进行详细研究,对压力数据进行了频谱分析和空间谐波分解(SHD)。通过空间谐波分解,可以获得 DT 锥体中压力脉动的同步波动(柱塞分量)和异步波动(旋转分量)。在 DT 锥体中注入空气可成功抑制高振幅的低频脉动。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
文献相关原料
公司名称 产品信息 采购帮参考价格
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信