{"title":"Platinum chromium everolimus-eluting stents for the treatment of (complex) coronary artery disease; from SYNERGY™ to the MEGATRON™.","authors":"Pascal Frederiks, Gianluca Castaldi, Keir McCutcheon, Johan Bennett","doi":"10.1080/17434440.2024.2353722","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>The introduction of drug-eluting coronary stents (DES) into clinical practice in 2002 represented a major milestone in the treatment of obstructive coronary artery disease. Over the years, significant advances in polymer coating and in antiproliferative agent technology have further improved the safety and clinical performance of newer-generation DES.</p><p><strong>Areas covered: </strong>Development of platinum chromium (PtCr) alloys with high radial strength and high radiopacity have enabled the design of new, thin-strut, flexible, and highly trackable stent platforms, while simultaneously improving stent visibility. These advances have facilitated complex percutaneous treatment of a diverse population of patients in clinical practice. This review will provide an overview of the evolution in PtCr everolimus-eluting stents from PROMUS Element™ to SYNERGY™ to the recently introduced SYNERGY MEGATRON™. The clinical data will be summarized and put into perspective, especially focusing on the role of the SYNERGY™ and MEGATRON™ platforms in the treatment of complex coronary artery disease and high-risk patients.</p><p><strong>Expert opinion: </strong>The SYNERGY™ stent demonstrates favorable clinical efficacy and safety outcome data, and whilst the clinical data on MEGATRON™ are sparse, early experience is promising. The specific overexpansion capabilities, visibility, and radial strength of the MEGATRON™ are attractive features for complex coronary interventions.</p>","PeriodicalId":94006,"journal":{"name":"Expert review of medical devices","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Expert review of medical devices","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/17434440.2024.2353722","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/5/13 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: The introduction of drug-eluting coronary stents (DES) into clinical practice in 2002 represented a major milestone in the treatment of obstructive coronary artery disease. Over the years, significant advances in polymer coating and in antiproliferative agent technology have further improved the safety and clinical performance of newer-generation DES.

Areas covered: Development of platinum chromium (PtCr) alloys with high radial strength and high radiopacity have enabled the design of new, thin-strut, flexible, and highly trackable stent platforms, while simultaneously improving stent visibility. These advances have facilitated complex percutaneous treatment of a diverse population of patients in clinical practice. This review will provide an overview of the evolution in PtCr everolimus-eluting stents from PROMUS Element™ to SYNERGY™ to the recently introduced SYNERGY MEGATRON™. The clinical data will be summarized and put into perspective, especially focusing on the role of the SYNERGY™ and MEGATRON™ platforms in the treatment of complex coronary artery disease and high-risk patients.

Expert opinion: The SYNERGY™ stent demonstrates favorable clinical efficacy and safety outcome data, and whilst the clinical data on MEGATRON™ are sparse, early experience is promising. The specific overexpansion capabilities, visibility, and radial strength of the MEGATRON™ are attractive features for complex coronary interventions.

用于治疗(复杂)冠状动脉疾病的铂铬依维莫司洗脱支架;从 SYNERGY™ 到 MEGATRON™。
导言:2002年,药物洗脱冠状动脉支架(DES)被引入临床实践,这是治疗阻塞性冠状动脉疾病的一个重要里程碑。多年来,聚合物涂层和抗增殖剂技术的重大进步进一步提高了新一代药物洗脱冠状动脉支架的安全性和临床表现:具有高径向强度和高放射韧性的铂铬(PtCr)合金的开发使新型、薄支架、柔性和高可追踪性支架平台的设计成为可能,同时提高了支架的可视性。这些进步有助于在临床实践中对不同患者进行复杂的经皮治疗。本综述将概述铂铬(PtCr)依维莫司洗脱支架从 PROMUS Element™ 到 SYNERGY™ 再到最近推出的 SYNERGY MEGATRON™的发展历程。将对临床数据进行总结和透视,尤其是重点关注 SYNERGY™ 和 MEGATRON™ 平台在治疗复杂冠状动脉疾病和高危患者方面的作用:专家意见:SYNERGY™支架的临床疗效和安全性数据良好,而MEGATRON™的临床数据稀少,但早期数据很有希望。MEGATRON™ 的特殊过扩张能力、可视性和径向强度对于复杂的冠状动脉介入治疗具有吸引力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信