{"title":"V-Shaped Incision of the Proximal Cartilage for High-Caliber Mismatch in Bronchoplasty","authors":"Yukio Watanabe MD , Aritoshi Hattori MD , Mariko Fukui MD , Takeshi Matsunaga MD , Kazuya Takamochi MD , Hisashi Tomita PhD , Kenji Suzuki MD","doi":"10.1016/j.atssr.2024.04.006","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>The problem of high-caliber mismatch in bronchoplasty is not uncommon. This report describes a technique using a V-shaped proximal cartilage incision to adjust high-caliber mismatch.</div></div><div><h3>Methods</h3><div>Among 255 patients who underwent tracheoplasty or bronchoplasty at a single institution (Juntendo University School of Medicine, Tokyo, Japan) between February 2008 and December 2022, 12 patients (4.7%) who underwent bronchoplasty with a proximal cartilage V-shaped incision for the adjustment of high-caliber mismatch were investigated. Bronchial anastomosis was performed using a continuous running monofilament suture at the bottom of the cartilage. Interrupted 3-0 or 4-0 monofilament sutures were used for the remaining cartilaginous tissue. Before completing the cartilaginous suture, a V-shaped incision was made in the proximal cartilage at the junction of the membranous portion. The cartilage and membranous portion of the incision were sutured using 3 interrupted sutures with 4-0 polydioxanone sutures. Finally, the membranous portion was sutured to complete the anastomosis.</div></div><div><h3>Results</h3><div>Eleven patients were men, and the median age was 66 years. The histologic diagnoses were adenocarcinoma in 2 patients and squamous cell carcinoma in 10 patients. Three patients underwent operation after definitive chemoradiotherapy. Right sleeve pneumonectomy, right upper sleeve lobectomy, type A extended-sleeve lobectomy, and type C extended-sleeve lobectomy were performed in 7 patients, 3 patients, 1 patient, and 1 patient, respectively. No anastomotic complications were observed. The V-shaped incision group had a significantly higher frequency of right sleeve pneumonectomy than the group without the V-shaped incision (<em>P</em> < .01).</div></div><div><h3>Conclusions</h3><div>Creation of a proximal cartilaginous V-shaped incision is a useful technique for adjusting high-caliber mismatch, especially in right sleeve pneumonectomy.</div></div>","PeriodicalId":72234,"journal":{"name":"Annals of thoracic surgery short reports","volume":"3 1","pages":"Pages 128-132"},"PeriodicalIF":0.0000,"publicationDate":"2025-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of thoracic surgery short reports","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2772993124001864","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Background
The problem of high-caliber mismatch in bronchoplasty is not uncommon. This report describes a technique using a V-shaped proximal cartilage incision to adjust high-caliber mismatch.
Methods
Among 255 patients who underwent tracheoplasty or bronchoplasty at a single institution (Juntendo University School of Medicine, Tokyo, Japan) between February 2008 and December 2022, 12 patients (4.7%) who underwent bronchoplasty with a proximal cartilage V-shaped incision for the adjustment of high-caliber mismatch were investigated. Bronchial anastomosis was performed using a continuous running monofilament suture at the bottom of the cartilage. Interrupted 3-0 or 4-0 monofilament sutures were used for the remaining cartilaginous tissue. Before completing the cartilaginous suture, a V-shaped incision was made in the proximal cartilage at the junction of the membranous portion. The cartilage and membranous portion of the incision were sutured using 3 interrupted sutures with 4-0 polydioxanone sutures. Finally, the membranous portion was sutured to complete the anastomosis.
Results
Eleven patients were men, and the median age was 66 years. The histologic diagnoses were adenocarcinoma in 2 patients and squamous cell carcinoma in 10 patients. Three patients underwent operation after definitive chemoradiotherapy. Right sleeve pneumonectomy, right upper sleeve lobectomy, type A extended-sleeve lobectomy, and type C extended-sleeve lobectomy were performed in 7 patients, 3 patients, 1 patient, and 1 patient, respectively. No anastomotic complications were observed. The V-shaped incision group had a significantly higher frequency of right sleeve pneumonectomy than the group without the V-shaped incision (P < .01).
Conclusions
Creation of a proximal cartilaginous V-shaped incision is a useful technique for adjusting high-caliber mismatch, especially in right sleeve pneumonectomy.