Far cortical locking constructs for fixation of distal femur fractures in an Asian population: A prospective observational study

IF 1.5 4区 医学 Q3 ORTHOPEDICS
Eic Ju Lim , Jae-Woo Cho , Oog-Jin Shon , Jong-Keon Oh , Kyu Tae Hwang , Gwang Chul Lee
{"title":"Far cortical locking constructs for fixation of distal femur fractures in an Asian population: A prospective observational study","authors":"Eic Ju Lim ,&nbsp;Jae-Woo Cho ,&nbsp;Oog-Jin Shon ,&nbsp;Jong-Keon Oh ,&nbsp;Kyu Tae Hwang ,&nbsp;Gwang Chul Lee","doi":"10.1016/j.jos.2024.03.007","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>The stiffness of locked plates suppresses healing process, prompting the introduction of far cortical locking to address this issue. This study aimed to demonstrate the clinical efficacy of far cortical locking constructs in treating distal femoral fractures in an Asian population.</div></div><div><h3>Methods</h3><div>This multicenter prospective observational study was conducted at four university hospitals between February 2018 and February 2021. Demographic data, the presence of metaphyseal comminution, and surgical fixation details were recorded. Clinical outcomes, including single-leg standing, EQ-5D, and EQ-VAS scores, and radiologic outcomes, including the RUST score of each cortex, were evaluated and compared according to the presence of metaphyseal comminution.</div></div><div><h3>Results</h3><div>There were 37 patients (14 men and 23 women) with a mean age of 67.3 ± 11.8 years. Twenty-two patients had metaphyseal comminution (59%), and 15 presented simple fractures in metaphyseal areas. Four patients (13%) could stand on one leg &gt;10s at 6 weeks, and 24 patients (92%) at 1 year. EQ-5D increased from 0.022 ± 0.388 to 0.692 ± 0.347, and the mean EQ-VAS 51.1 ± 13.1 to 74.1 ± 24.1 between discharge (n = 37) and post-operative 1 year (n = 33), respectively. RUST score presented increment for time, from 6.2 ± 1.8 at 6 week to 11.6 ± 1.1 at 1 year. Radiological healing demonstrated rapid increase from week 6 (16/28, 43%) to month 3 (27/31, 87%), with no obvious increase was observed in 6 months (23/26, 89%) or 12 months (25/28, 89%). Simple metaphyseal fractures presented significantly higher RUST scores at 6 weeks and 3 months, but there was no difference in RUST scores at 6 months or 1 year according to metaphyseal comminution.</div></div><div><h3>Conclusions</h3><div>Plate constructs with far cortical locking screws provided safe and effective fixation for distal femoral fractures, with consistent radiological and clinical results, regardless of metaphyseal comminution.</div></div>","PeriodicalId":16939,"journal":{"name":"Journal of Orthopaedic Science","volume":"30 2","pages":"Pages 372-378"},"PeriodicalIF":1.5000,"publicationDate":"2025-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Orthopaedic Science","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0949265824000526","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Background

The stiffness of locked plates suppresses healing process, prompting the introduction of far cortical locking to address this issue. This study aimed to demonstrate the clinical efficacy of far cortical locking constructs in treating distal femoral fractures in an Asian population.

Methods

This multicenter prospective observational study was conducted at four university hospitals between February 2018 and February 2021. Demographic data, the presence of metaphyseal comminution, and surgical fixation details were recorded. Clinical outcomes, including single-leg standing, EQ-5D, and EQ-VAS scores, and radiologic outcomes, including the RUST score of each cortex, were evaluated and compared according to the presence of metaphyseal comminution.

Results

There were 37 patients (14 men and 23 women) with a mean age of 67.3 ± 11.8 years. Twenty-two patients had metaphyseal comminution (59%), and 15 presented simple fractures in metaphyseal areas. Four patients (13%) could stand on one leg >10s at 6 weeks, and 24 patients (92%) at 1 year. EQ-5D increased from 0.022 ± 0.388 to 0.692 ± 0.347, and the mean EQ-VAS 51.1 ± 13.1 to 74.1 ± 24.1 between discharge (n = 37) and post-operative 1 year (n = 33), respectively. RUST score presented increment for time, from 6.2 ± 1.8 at 6 week to 11.6 ± 1.1 at 1 year. Radiological healing demonstrated rapid increase from week 6 (16/28, 43%) to month 3 (27/31, 87%), with no obvious increase was observed in 6 months (23/26, 89%) or 12 months (25/28, 89%). Simple metaphyseal fractures presented significantly higher RUST scores at 6 weeks and 3 months, but there was no difference in RUST scores at 6 months or 1 year according to metaphyseal comminution.

Conclusions

Plate constructs with far cortical locking screws provided safe and effective fixation for distal femoral fractures, with consistent radiological and clinical results, regardless of metaphyseal comminution.
远皮质锁定结构用于固定亚洲人的股骨远端骨折:前瞻性观察研究
背景锁定钢板的刚度抑制愈合过程,促使引入远皮质锁定来解决这一问题。本研究旨在证明远端皮质锁定装置治疗亚洲人群股骨远端骨折的临床疗效。方法本多中心前瞻性观察研究于2018年2月至2021年2月在四所大学医院进行。记录了人口统计学数据、干骺端粉碎情况和手术固定细节。临床结果包括单腿站立、EQ-5D和EQ-VAS评分,放射学结果包括各皮质的RUST评分,根据干骺端粉碎的存在进行评估和比较。结果37例患者(男14例,女23例),平均年龄67.3±11.8岁。22例患者有干骺端粉碎(59%),15例患者有干骺端单纯性骨折。4例患者(13%)在6周时可以单腿站立,24例患者(92%)在1年内可以单腿站立。出院(n = 37)至术后1年(n = 33), EQ-5D从0.022±0.388上升至0.692±0.347,平均EQ-VAS从51.1±13.1上升至74.1±24.1。RUST评分随时间增加,从6周的6.2±1.8分增加到1年的11.6±1.1分。放射学愈合从第6周(16/ 28,43%)到第3个月(27/ 31,87%)迅速增加,6个月(23/ 26,89%)或12个月(25/ 28,89%)无明显增加。单纯干骺端骨折在6周和3个月时RUST评分明显较高,但根据干骺端粉碎情况,6个月和1年时RUST评分无差异。结论钢板结构与远端皮质锁定螺钉为股骨远端骨折提供了安全有效的固定,无论干骺端粉碎与否,其放射学和临床结果一致。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Orthopaedic Science
Journal of Orthopaedic Science 医学-整形外科
CiteScore
3.00
自引率
0.00%
发文量
290
审稿时长
90 days
期刊介绍: The Journal of Orthopaedic Science is the official peer-reviewed journal of the Japanese Orthopaedic Association. The journal publishes the latest researches and topical debates in all fields of clinical and experimental orthopaedics, including musculoskeletal medicine, sports medicine, locomotive syndrome, trauma, paediatrics, oncology and biomaterials, as well as basic researches.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信