Pre-processing the Photoplethysmography Signals for Enhancing the Cardiovascular Diseases Detection for Wrist Pulse Analysis in Nadi Ayurveda

Aditya Tandon, Vivek Kumar, Tanupriya Choudhury
{"title":"Pre-processing the Photoplethysmography Signals for Enhancing the Cardiovascular Diseases Detection for Wrist Pulse Analysis in Nadi Ayurveda","authors":"Aditya Tandon, Vivek Kumar, Tanupriya Choudhury","doi":"10.4108/eetpht.10.5640","DOIUrl":null,"url":null,"abstract":"INTRODUCTION: In recent years, Photoplethysmography (PPG) signal has played a vital role in detecting Cardiovascular Diseases (CVDs) in case of wrist pulse analysis emulating the Nadi Ayurveda. The PPG signals acquired from the sensor measurement are severely distorted by various artifacts, which significantly impact the accuracy of disease detection and hamper the disease diagnosis process. \nOBJECTIVES: Removing the noises is essential before detecting CVDs from the signals and thus, developing a simple and effective noise reduction method for enhancing the PPG signal quality constitutes a challenging research problem, particularly with prominent artifacts. \nMETHODS: This paper designs an effective pre-processing technique that improves denoising methods to enhance the PPG signal quality. The design of pre-processing technique contains two major phases: Primary denoising-based artifact removal and secondary denoising-based Premature Ventricular Contraction (PVC) detection and Power-Line Interference (PLI) noise removal. The primary denoising method involves coarse and fine-grained filtering. The coarse-grained filtering removes the major artifacts, such as Baseline Wander (BLW) and Motion Artifacts (MA), by developing the Two-Stage Adaptive Noise Canceller (TANC) method. The fine-grained filtering process utilizes a detrended filter to filter the refined signal obtained from the TANC method. For the signals filtered from the primary denoising method, the secondary denoising method targets to detect the PVC-induced PPG signals from the decomposed high-frequency signals and removes high-frequency noise, such as PLI from noisy signals, by adopting the Wavelet Transform (WT) method. \nRESULTS: During the signal reconstruction process in the WT method, the research work reconstructs the denoised PPG signals along with the PVC-induced PPG signals. The experimental results of the noise removal methodology illustrated significant improvements in PPG signal quality. \nCONCLUSION: The designed pre-processing technique effectively denoises PPG signals, leading to enhanced signal quality which can further aid in accurate disease detection.","PeriodicalId":506478,"journal":{"name":"EAI Endorsed Transactions on Pervasive Health and Technology","volume":"14 4","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-04-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"EAI Endorsed Transactions on Pervasive Health and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4108/eetpht.10.5640","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

INTRODUCTION: In recent years, Photoplethysmography (PPG) signal has played a vital role in detecting Cardiovascular Diseases (CVDs) in case of wrist pulse analysis emulating the Nadi Ayurveda. The PPG signals acquired from the sensor measurement are severely distorted by various artifacts, which significantly impact the accuracy of disease detection and hamper the disease diagnosis process. OBJECTIVES: Removing the noises is essential before detecting CVDs from the signals and thus, developing a simple and effective noise reduction method for enhancing the PPG signal quality constitutes a challenging research problem, particularly with prominent artifacts. METHODS: This paper designs an effective pre-processing technique that improves denoising methods to enhance the PPG signal quality. The design of pre-processing technique contains two major phases: Primary denoising-based artifact removal and secondary denoising-based Premature Ventricular Contraction (PVC) detection and Power-Line Interference (PLI) noise removal. The primary denoising method involves coarse and fine-grained filtering. The coarse-grained filtering removes the major artifacts, such as Baseline Wander (BLW) and Motion Artifacts (MA), by developing the Two-Stage Adaptive Noise Canceller (TANC) method. The fine-grained filtering process utilizes a detrended filter to filter the refined signal obtained from the TANC method. For the signals filtered from the primary denoising method, the secondary denoising method targets to detect the PVC-induced PPG signals from the decomposed high-frequency signals and removes high-frequency noise, such as PLI from noisy signals, by adopting the Wavelet Transform (WT) method. RESULTS: During the signal reconstruction process in the WT method, the research work reconstructs the denoised PPG signals along with the PVC-induced PPG signals. The experimental results of the noise removal methodology illustrated significant improvements in PPG signal quality. CONCLUSION: The designed pre-processing technique effectively denoises PPG signals, leading to enhanced signal quality which can further aid in accurate disease detection.
预处理光敏血压计信号以增强纳迪阿育吠陀中手腕脉搏分析的心血管疾病检测能力
引言:近年来,在模仿 Nadi Ayurveda 的腕部脉搏分析中,光电血压计(PPG)信号在检测心血管疾病(CVD)方面发挥了重要作用。从传感器测量中获取的 PPG 信号因各种伪像而严重失真,严重影响了疾病检测的准确性,阻碍了疾病诊断过程。目标:因此,开发一种简单有效的降噪方法来提高 PPG 信号的质量是一个具有挑战性的研究课题,尤其是在伪差比较突出的情况下。方法:本文设计了一种有效的预处理技术,可改进去噪方法以提高 PPG 信号质量。预处理技术的设计包含两个主要阶段:基于一次去噪的伪影去除和基于二次去噪的室性早搏(PVC)检测和电源线干扰(PLI)噪声去除。初级去噪方法包括粗粒度和细粒度滤波。粗粒度滤波通过开发两阶段自适应噪声消除器(TANC)方法,去除基线漂移(BLW)和运动伪影(MA)等主要伪影。细粒度过滤过程利用去趋势滤波器对 TANC 方法得到的细化信号进行过滤。对于一级去噪方法过滤后的信号,二级去噪方法的目标是从分解后的高频信号中检测出 PVC 诱导的 PPG 信号,并采用小波变换(WT)方法去除高频噪声,如噪声信号中的 PLI。结果:在小波变换方法的信号重建过程中,研究工作在重建去噪 PPG 信号的同时,也重建了 PVC 诱导的 PPG 信号。去噪方法的实验结果表明,PPG 信号质量有了显著改善。结论:所设计的预处理技术能有效地对 PPG 信号进行去噪处理,从而提高信号质量,进一步帮助准确检测疾病。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书