Comparative Analysis of Current-Voltage Characteristics of Photovoltaic (PV) Systems in Selected Climatic Regions in Cross River State, Nigeria

Emmanuel B. Ettah, Goodness N. Nwabueze, U. J. Ekah
{"title":"Comparative Analysis of Current-Voltage Characteristics of Photovoltaic (PV) Systems in Selected Climatic Regions in Cross River State, Nigeria","authors":"Emmanuel B. Ettah, Goodness N. Nwabueze, U. J. Ekah","doi":"10.9734/jenrr/2024/v16i4345","DOIUrl":null,"url":null,"abstract":"This study investigated the effect of solar radiation’s intensity and ambient temperature on the current-voltage (I-V) characteristics of monocrystalline and polycrystalline photovoltaic (PV) systems in the generation of electricity in Calabar and Okuku, Cross River State, Nigeria. Appropriate measuring devices were employed to record daily readings of these parameters at the study locations, from July to August 2022. The data were collected and results graphically analyzed and calculated. The results indicate that current (Isc), voltage (Voc) as well as the maximum power (Pmax) of both module types increased positively with increase in solar radiation and ambient temperature. Results from collected and computed data also show average daily readings across the locations for solar radiation ranging between 271Wm-2 and 409Wm-2 and ambient temperature between 320C and 370C. The calculated Pmax ranges between 49W and 63W from the 130W solar modules used for the investigation. Another notable result is that the polycrystalline module exhibits higher Pmax than the monocrystalline module in both locations. In spite of the low solar radiation and ambient temperature obtained during this study period, which is considered the worst climatic period of the year (July and August), it is desirable and recommendable to employ solar modules as an alternative power generation in Calabar and Okuku, Cross River State, Nigeria.","PeriodicalId":499811,"journal":{"name":"Journal of Energy Research and Reviews","volume":"23 2","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-04-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Energy Research and Reviews","FirstCategoryId":"0","ListUrlMain":"https://doi.org/10.9734/jenrr/2024/v16i4345","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This study investigated the effect of solar radiation’s intensity and ambient temperature on the current-voltage (I-V) characteristics of monocrystalline and polycrystalline photovoltaic (PV) systems in the generation of electricity in Calabar and Okuku, Cross River State, Nigeria. Appropriate measuring devices were employed to record daily readings of these parameters at the study locations, from July to August 2022. The data were collected and results graphically analyzed and calculated. The results indicate that current (Isc), voltage (Voc) as well as the maximum power (Pmax) of both module types increased positively with increase in solar radiation and ambient temperature. Results from collected and computed data also show average daily readings across the locations for solar radiation ranging between 271Wm-2 and 409Wm-2 and ambient temperature between 320C and 370C. The calculated Pmax ranges between 49W and 63W from the 130W solar modules used for the investigation. Another notable result is that the polycrystalline module exhibits higher Pmax than the monocrystalline module in both locations. In spite of the low solar radiation and ambient temperature obtained during this study period, which is considered the worst climatic period of the year (July and August), it is desirable and recommendable to employ solar modules as an alternative power generation in Calabar and Okuku, Cross River State, Nigeria.
尼日利亚克罗斯河州部分气候区光伏 (PV) 系统电流电压特性的比较分析
本研究调查了太阳辐射强度和环境温度对尼日利亚克罗斯河州卡拉巴尔和奥库库单晶和多晶光伏发电系统电流电压(I-V)特性的影响。2022 年 7 月至 8 月期间,在研究地点使用了适当的测量设备记录这些参数的每日读数。收集数据后,对结果进行了图形分析和计算。结果表明,两种类型模块的电流(Isc)、电压(Voc)和最大功率(Pmax)都随着太阳辐射和环境温度的增加而正增长。收集和计算的数据结果还显示,各地点的日平均太阳辐射读数介于 271Wm-2 和 409Wm-2 之间,环境温度介于 320C 和 370C 之间。调查中使用的 130 瓦太阳能电池组件的计算最大功率介于 49 瓦到 63 瓦之间。另一个值得注意的结果是,在这两个地点,多晶组件的 Pmax 均高于单晶组件。尽管本研究期间的太阳辐射和环境温度较低,被认为是一年中气候最恶劣的时期(七月和八月),但在尼日利亚克罗斯河州的卡拉巴尔和奥库克采用太阳能组件作为替代发电方式是可取的,也是值得推荐的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信