Effect of 30˚C Electrolyte Temperature on The Sensitivity Cu/Ni

M. Toifur, Rizka Nuzul Islamiyati
{"title":"Effect of 30˚C Electrolyte Temperature on The Sensitivity Cu/Ni","authors":"M. Toifur, Rizka Nuzul Islamiyati","doi":"10.21009/spektra.091.01","DOIUrl":null,"url":null,"abstract":"Given the necessity of cryogenic storage and monitoring cryogenic temperatures is equally important. This study aims to determine the resistance value and sensitivity of copper wire before and after electroplating at 30˚C electrolyte temperature as a low temperature sensor. The electrolyte solution consists of NiSO4 260 g, NiCl2 60 g, H3BO3 40 g and Aquades 1000 mL. Electroplating was carried out with an electrolyte temperature of 30˚C, electrode distance of 4 cm, voltage of 4.5 volts and plating time of 4 minutes. The plating results were analyzed to determine the resistance and sensitivity of the sensor at temperatures from 0 to -160˚C. The results showed that the resistance value of the Cu coil obtained RCu = (1.44 ± 0.00) ohm and the resistance of the Cu/Ni coil RCu / Ni = (1.50 ± 0.00) ohm. The resistance value on the Cu/Ni coil (after plating) is greater than the Cu coil (before plating). While the test results of sensor sensitivity show that Cu and Cu/Ni coils have properties as low temperature sensors. Sensor sensitivity increases after plating. The sensitivity value obtained by Cu coil is S(T) = -1E-06T + 6E-05 and Cu/Ni coil S(T) = -2E-06T + 2E-05. The projection sensitivity at a temperature of -200 ˚C obtained is 0.00046 V/˚C less than the Cu/Ni coil 0.00082 V/˚C. So nickel plating on copper coil at 30˚C electrolyte temperature has successfully improved the sensitivity value of the low-temperature sensor.","PeriodicalId":117601,"journal":{"name":"Spektra: Jurnal Fisika dan Aplikasinya","volume":" 3","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-04-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Spektra: Jurnal Fisika dan Aplikasinya","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21009/spektra.091.01","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Given the necessity of cryogenic storage and monitoring cryogenic temperatures is equally important. This study aims to determine the resistance value and sensitivity of copper wire before and after electroplating at 30˚C electrolyte temperature as a low temperature sensor. The electrolyte solution consists of NiSO4 260 g, NiCl2 60 g, H3BO3 40 g and Aquades 1000 mL. Electroplating was carried out with an electrolyte temperature of 30˚C, electrode distance of 4 cm, voltage of 4.5 volts and plating time of 4 minutes. The plating results were analyzed to determine the resistance and sensitivity of the sensor at temperatures from 0 to -160˚C. The results showed that the resistance value of the Cu coil obtained RCu = (1.44 ± 0.00) ohm and the resistance of the Cu/Ni coil RCu / Ni = (1.50 ± 0.00) ohm. The resistance value on the Cu/Ni coil (after plating) is greater than the Cu coil (before plating). While the test results of sensor sensitivity show that Cu and Cu/Ni coils have properties as low temperature sensors. Sensor sensitivity increases after plating. The sensitivity value obtained by Cu coil is S(T) = -1E-06T + 6E-05 and Cu/Ni coil S(T) = -2E-06T + 2E-05. The projection sensitivity at a temperature of -200 ˚C obtained is 0.00046 V/˚C less than the Cu/Ni coil 0.00082 V/˚C. So nickel plating on copper coil at 30˚C electrolyte temperature has successfully improved the sensitivity value of the low-temperature sensor.
30˚C 电解液温度对铜/镍灵敏度的影响
鉴于低温储存的必要性,监测低温同样重要。本研究旨在确定作为低温传感器的铜线在 30˚C 电解液温度下电镀前后的电阻值和灵敏度。电解质溶液由 260 克 NiSO4、60 克 NiCl2、40 克 H3BO3 和 1000 毫升 Aquades 组成。电镀温度为 30˚C,电极距离为 4 厘米,电压为 4.5 伏,电镀时间为 4 分钟。对电镀结果进行了分析,以确定传感器在 0 至 -160˚C 温度下的电阻值和灵敏度。结果显示,铜线圈的电阻值为 RCu = (1.44 ± 0.00) 欧姆,铜/镍线圈的电阻值为 RCu / Ni = (1.50 ± 0.00) 欧姆。铜/镍线圈(电镀后)的电阻值大于铜线圈(电镀前)。传感器灵敏度的测试结果表明,铜线圈和铜/镍线圈具有低温传感器的特性。电镀后传感器灵敏度增加。铜线圈的灵敏度值为 S(T) = -1E-06T + 6E-05,铜/镍线圈的灵敏度值为 S(T) = -2E-06T + 2E-05。温度为 -200 ˚C 时的投影灵敏度为 0.00046 V/˚C,低于铜/镍线圈的 0.00082 V/˚C。因此,在 30 ˚C 电解液温度下在铜线圈上镀镍成功地提高了低温传感器的灵敏度值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信