Soft and hard tissue evaluation of guided socket shield implant cases.

IF 0.9 Q3 DENTISTRY, ORAL SURGERY & MEDICINE
P. Trejo, Raysa Rivas, Corletta C Trejo, Seiko Min, Arisa Nishikawa
{"title":"Soft and hard tissue evaluation of guided socket shield implant cases.","authors":"P. Trejo, Raysa Rivas, Corletta C Trejo, Seiko Min, Arisa Nishikawa","doi":"10.1002/cap.10290","DOIUrl":null,"url":null,"abstract":"BACKGROUND\nThe socket-shield (SS) technique results in long-term functional osseo- and dento-integration, preserving the dimensional stability of hard and soft tissues over time. This study aimed to describe the successful implementation of a surgical technique to facilitate \"SS\" cases.\n\n\nMETHODS\nThe cases included males and females aged 32-81 years consecutively treated between 2020 and 2023 (longest follow-up, 3.5 years). For each case, pre- and post-operative cone-beam computed tomography (Digital Imaging and Communications in Medicine files) and intraoral optical scans (IOS; STL files) were performed. Digital immediate implant placement and simultaneous tooth extraction and SS production were planned using an implant planning software. Implants were planned considering sagittal-ridge and tooth-root angular-configuration. Surgical guides were used to perform the digitally-supported SS technique. All cases were planned and surgically performed by one operator (Pedro M. Trejo). Preoperative digital IOS-models were superimposed to post-operative models to assess soft-tissue changes. Pre and post sagittal views were used to assess the radiographic buccal-plate thickness at various healing times. An investigator not involved with case planning or treatment performed measurements.\n\n\nRESULTS\nResults reflected soft-tissue stability with minimal mean thickness change at 0-, 1-, 2-, and 3-mm measurement levels of 0.03, -0.2, 0.14, -0.07, and 0.04 mm, respectively, with a mean gingival-margin change of 0.04 mm. The free gingival-margin change ranged from a 0.58-mm gain in height to a -0.57-mm loss. The mean radiographic buccal-plate thickness post-operatively was 2.04 mm (range, 0.7-2.9 mm).\n\n\nCONCLUSION\nThe digitally-supported guided SS technique enables predictable immediate implant-placement positions and stable buccal peri-implant soft and hard tissues over time.\n\n\nKEY POINTS\nWhy are these cases new information? The uniqueness of the surgical technique described herein is that it results in favorable positions of immediate, socket-shielded (SSed), implant placements, with soft- and hard-tissue stability as the byproduct. What are the keys to successful management of these cases? Digitally, plan for the best possible implant position within the alveolar housing to satisfy prosthetic requirements, and then adjust this position to accommodate the socket shield dimensions. Digitally, provide a space/gap between the future dentinal shield and the implant. Clinically, allow for time to carve the final position and dimensions of the shield. Plan ahead the extent of the apical third of the SS, and the removal of the apex, if dealing with a long root. What are the primary limitations to success in these cases? Inadequate use of digital technology; case-sensitive technique requires proper execution of each digital and technical clinical step.","PeriodicalId":55950,"journal":{"name":"Clinical Advances in Periodontics","volume":null,"pages":null},"PeriodicalIF":0.9000,"publicationDate":"2024-04-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Advances in Periodontics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/cap.10290","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

BACKGROUND The socket-shield (SS) technique results in long-term functional osseo- and dento-integration, preserving the dimensional stability of hard and soft tissues over time. This study aimed to describe the successful implementation of a surgical technique to facilitate "SS" cases. METHODS The cases included males and females aged 32-81 years consecutively treated between 2020 and 2023 (longest follow-up, 3.5 years). For each case, pre- and post-operative cone-beam computed tomography (Digital Imaging and Communications in Medicine files) and intraoral optical scans (IOS; STL files) were performed. Digital immediate implant placement and simultaneous tooth extraction and SS production were planned using an implant planning software. Implants were planned considering sagittal-ridge and tooth-root angular-configuration. Surgical guides were used to perform the digitally-supported SS technique. All cases were planned and surgically performed by one operator (Pedro M. Trejo). Preoperative digital IOS-models were superimposed to post-operative models to assess soft-tissue changes. Pre and post sagittal views were used to assess the radiographic buccal-plate thickness at various healing times. An investigator not involved with case planning or treatment performed measurements. RESULTS Results reflected soft-tissue stability with minimal mean thickness change at 0-, 1-, 2-, and 3-mm measurement levels of 0.03, -0.2, 0.14, -0.07, and 0.04 mm, respectively, with a mean gingival-margin change of 0.04 mm. The free gingival-margin change ranged from a 0.58-mm gain in height to a -0.57-mm loss. The mean radiographic buccal-plate thickness post-operatively was 2.04 mm (range, 0.7-2.9 mm). CONCLUSION The digitally-supported guided SS technique enables predictable immediate implant-placement positions and stable buccal peri-implant soft and hard tissues over time. KEY POINTS Why are these cases new information? The uniqueness of the surgical technique described herein is that it results in favorable positions of immediate, socket-shielded (SSed), implant placements, with soft- and hard-tissue stability as the byproduct. What are the keys to successful management of these cases? Digitally, plan for the best possible implant position within the alveolar housing to satisfy prosthetic requirements, and then adjust this position to accommodate the socket shield dimensions. Digitally, provide a space/gap between the future dentinal shield and the implant. Clinically, allow for time to carve the final position and dimensions of the shield. Plan ahead the extent of the apical third of the SS, and the removal of the apex, if dealing with a long root. What are the primary limitations to success in these cases? Inadequate use of digital technology; case-sensitive technique requires proper execution of each digital and technical clinical step.
对导槽屏蔽种植体病例进行软组织和硬组织评估。
背景Socket-shield(SS)技术可实现长期的功能性骨牙融合,长期保持软硬组织的尺寸稳定性。本研究旨在描述成功实施 "SS "病例的手术技术。方法病例包括年龄在 32-81 岁之间的男性和女性,他们在 2020 年至 2023 年期间接受了连续治疗(最长随访时间为 3.5 年)。每个病例都进行了术前和术后锥形束计算机断层扫描(医学数字成像和通信文件)和口内光学扫描(IOS;STL 文件)。使用种植规划软件对数字化即刻种植体植入、同步拔牙和 SS 生产进行了规划。规划种植体时考虑了矢状嵴和牙根角度配置。使用手术导板进行数字支持 SS 技术。所有病例均由一名操作者(Pedro M. Trejo)进行规划和手术。术前数字 IOS 模型与术后模型叠加,以评估软组织变化。术前和术后矢状切面用于评估不同愈合时间的颊板厚度。结果显示软组织稳定,0、1、2 和 3 毫米测量水平的平均厚度变化最小,分别为 0.03、-0.2、0.14、-0.07 和 0.04 毫米,平均龈缘变化为 0.04 毫米。游离龈缘的变化范围从增高 0.58 毫米到降低-0.57 毫米不等。术后X光片显示的平均颊板厚度为2.04毫米(范围为0.7-2.9毫米)。关键要点为什么这些病例是新信息?本文所描述的手术技术的独特之处在于,它可以获得良好的即刻种植体植入位置、种植窝遮挡(SSed)以及软组织和硬组织的稳定性。成功处理这些病例的关键是什么?以数字化方式规划种植体在牙槽窝内的最佳位置,以满足修复要求,然后调整该位置以适应牙槽窝屏蔽的尺寸。在数字上,在未来的牙本质屏蔽和种植体之间留出空间/间隙。在临床上,为雕刻牙托的最终位置和尺寸留出时间。提前计划 SS 根尖三分之一的范围,如果牙根较长,还需要去除根尖。这些病例成功的主要限制因素是什么?对数字技术的使用不足;病例敏感技术要求正确执行每个数字和临床技术步骤。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Clinical Advances in Periodontics
Clinical Advances in Periodontics DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
1.60
自引率
0.00%
发文量
40
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信