{"title":"Combining Statistical Noise Levels and Application to Wind Farm Guidelines","authors":"Renzo Tonin","doi":"10.1007/s40857-024-00318-y","DOIUrl":null,"url":null,"abstract":"<div><p>It is stated in wind farm standards that logarithmic addition and subtraction of <i>L</i><sub>AF90<i>,T</i></sub> sound pressure levels is “not strictly mathematically correct”. An analytical and experimental study reported in Tonin 2024 (a related article) examines the underlying accuracy of combining statistical noise levels as a general proposition, particularly the <i>L</i><sub>AF90,<i>T</i></sub> and the <i>L</i><sub>AF10,<i>T</i></sub>. The objective of that study was to explore the accuracy of combining statistical noise levels and what might influence that accuracy. The objective of this study, as foreshadowed in Tonin 2024, is to apply the results to wind farms. It was concluded in Tonin 2024 that values of <i>D</i><sub>90</sub> (being the difference between the logarithmic sum and actual values of <i>L</i><sub>AF90,<i>T</i></sub>) are negative in the range 0 to − 3 dB (for the cases in the study), meaning that the logarithmic sum of <i>L</i><sub>AF90,<i>T</i></sub> for the ambient and source sound pressure level distributions is less than the actual value of <i>L</i><sub>AF90,<i>T</i></sub> for the combined distribution. As a result, in deriving the wind farm noise level (as a contribution), the actual value of <i>L</i><sub>AF90,<i>T</i></sub> will be less than that determined by logarithmic subtraction of the individual components. In respect of the question of the underlying accuracy of combining statistical noise levels for wind farms, it is concluded that the difference between the logarithmic addition of the <i>L</i><sub>AF90,<i>T</i></sub> and the true value is less than 1 dB (for the cases in the study). The results are applied herein to a typical wind farm concluding that the simple energy subtraction method adopted in wind farm guidelines is conservative even allowing for the hypothesis that the fluctuation strength of wind farm noise is not invariant but increases with distance. It is also concluded that if wind farm guidelines were to assess wind farm noise on the basis of <i>L</i><sub>Aeq,<i>T</i></sub> rather than <i>L</i><sub>AF90,<i>T</i></sub> then adding a value of 2.5 dB to the derived wind farm noise level <i>L</i><sub>AF90,<i>T</i></sub> as currently specified in the guidelines (i.e., with <i>D</i><sub>90</sub> = 0 dB) would be conservative even allowing for the hypothesis that the fluctuation strength of wind farm noise is not invariant but increases with distance.</p></div>","PeriodicalId":54355,"journal":{"name":"Acoustics Australia","volume":"52 2","pages":"263 - 272"},"PeriodicalIF":1.7000,"publicationDate":"2024-04-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acoustics Australia","FirstCategoryId":"101","ListUrlMain":"https://link.springer.com/article/10.1007/s40857-024-00318-y","RegionNum":4,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
It is stated in wind farm standards that logarithmic addition and subtraction of LAF90,T sound pressure levels is “not strictly mathematically correct”. An analytical and experimental study reported in Tonin 2024 (a related article) examines the underlying accuracy of combining statistical noise levels as a general proposition, particularly the LAF90,T and the LAF10,T. The objective of that study was to explore the accuracy of combining statistical noise levels and what might influence that accuracy. The objective of this study, as foreshadowed in Tonin 2024, is to apply the results to wind farms. It was concluded in Tonin 2024 that values of D90 (being the difference between the logarithmic sum and actual values of LAF90,T) are negative in the range 0 to − 3 dB (for the cases in the study), meaning that the logarithmic sum of LAF90,T for the ambient and source sound pressure level distributions is less than the actual value of LAF90,T for the combined distribution. As a result, in deriving the wind farm noise level (as a contribution), the actual value of LAF90,T will be less than that determined by logarithmic subtraction of the individual components. In respect of the question of the underlying accuracy of combining statistical noise levels for wind farms, it is concluded that the difference between the logarithmic addition of the LAF90,T and the true value is less than 1 dB (for the cases in the study). The results are applied herein to a typical wind farm concluding that the simple energy subtraction method adopted in wind farm guidelines is conservative even allowing for the hypothesis that the fluctuation strength of wind farm noise is not invariant but increases with distance. It is also concluded that if wind farm guidelines were to assess wind farm noise on the basis of LAeq,T rather than LAF90,T then adding a value of 2.5 dB to the derived wind farm noise level LAF90,T as currently specified in the guidelines (i.e., with D90 = 0 dB) would be conservative even allowing for the hypothesis that the fluctuation strength of wind farm noise is not invariant but increases with distance.
期刊介绍:
Acoustics Australia, the journal of the Australian Acoustical Society, has been publishing high quality research and technical papers in all areas of acoustics since commencement in 1972. The target audience for the journal includes both researchers and practitioners. It aims to publish papers and technical notes that are relevant to current acoustics and of interest to members of the Society. These include but are not limited to: Architectural and Building Acoustics, Environmental Noise, Underwater Acoustics, Engineering Noise and Vibration Control, Occupational Noise Management, Hearing, Musical Acoustics.