3T multiparametric MRI’s accuracy in detecting prostate cancer using Prostate Imaging Reporting and Data System (PIRADS) version 2.1 with prostate biopsy as a reference

IF 0.7 Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Mohammad Abdullah Dhulaimi, Moroj Ahmad Aldarmasi, Areen Ghazi Almasri, Syed Mohammad Mosharraf
{"title":"3T multiparametric MRI’s accuracy in detecting prostate cancer using Prostate Imaging Reporting and Data System (PIRADS) version 2.1 with prostate biopsy as a reference","authors":"Mohammad Abdullah Dhulaimi, Moroj Ahmad Aldarmasi, Areen Ghazi Almasri, Syed Mohammad Mosharraf","doi":"10.1186/s43055-024-01244-9","DOIUrl":null,"url":null,"abstract":"Multiparametric magnetic resonance imaging (MRI) is valuable in detecting prostate cancer due to its high sensitivity to malignant lesions. It is commonly utilized to improve the identification of clinically significant cancers within the prostate. This study aimed to correlate the findings from 3T multiparametric MRI of the prostate using the updated Prostate Imaging Reporting and Data System version 2.1 (PIRADSv2.1) from 2019 with reference to prostate biopsy results. Additionally, PIRADSv2.1 was used to calculate the sensitivity, specificity, positive predictive value, and negative predictive value of the 3T multiparametric MRI of the prostate. A retrospective study was conducted at a tertiary center, wherein we identified patients who underwent a prostate biopsy between June 2019 and June 2021 and had a corresponding MRI of the prostate performed at the same institution, evaluated with PIRADSv2.1 criteria. A total of 50 patients were eligible for final analysis. The prevalence of prostate cancer was 69% (95% confidence interval (CI) 54–81%). Receiver operating characteristic (ROC) curves were generated for 3T multiparametric MRI of the prostate using PIRADSv2.1 to diagnose prostate cancer; the area under the ROC curve was 0.81 (95% CI 0.68–0.95, p < 0.001). The sensitivity, specificity, positive predictive value, and negative predictive value of the 3T multiparametric prostate MRI using PIRADSv2.1 were 74.0%, 87.0%, 92.9%, and 59.1%, respectively. PIRADSv2.1 exhibited good overall performance in the diagnosis of prostate cancer.","PeriodicalId":11540,"journal":{"name":"Egyptian Journal of Radiology and Nuclear Medicine","volume":"298 1","pages":""},"PeriodicalIF":0.7000,"publicationDate":"2024-04-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Egyptian Journal of Radiology and Nuclear Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/s43055-024-01244-9","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Multiparametric magnetic resonance imaging (MRI) is valuable in detecting prostate cancer due to its high sensitivity to malignant lesions. It is commonly utilized to improve the identification of clinically significant cancers within the prostate. This study aimed to correlate the findings from 3T multiparametric MRI of the prostate using the updated Prostate Imaging Reporting and Data System version 2.1 (PIRADSv2.1) from 2019 with reference to prostate biopsy results. Additionally, PIRADSv2.1 was used to calculate the sensitivity, specificity, positive predictive value, and negative predictive value of the 3T multiparametric MRI of the prostate. A retrospective study was conducted at a tertiary center, wherein we identified patients who underwent a prostate biopsy between June 2019 and June 2021 and had a corresponding MRI of the prostate performed at the same institution, evaluated with PIRADSv2.1 criteria. A total of 50 patients were eligible for final analysis. The prevalence of prostate cancer was 69% (95% confidence interval (CI) 54–81%). Receiver operating characteristic (ROC) curves were generated for 3T multiparametric MRI of the prostate using PIRADSv2.1 to diagnose prostate cancer; the area under the ROC curve was 0.81 (95% CI 0.68–0.95, p < 0.001). The sensitivity, specificity, positive predictive value, and negative predictive value of the 3T multiparametric prostate MRI using PIRADSv2.1 were 74.0%, 87.0%, 92.9%, and 59.1%, respectively. PIRADSv2.1 exhibited good overall performance in the diagnosis of prostate cancer.
使用前列腺成像报告和数据系统(PIRADS)2.1 版和前列腺活检作为参考,3T 多参数磁共振成像检测前列腺癌的准确性
多参数磁共振成像(MRI)对恶性病变的敏感性很高,因此在检测前列腺癌方面很有价值。它通常用于提高对前列腺内具有临床意义的癌症的识别率。本研究旨在参考前列腺活检结果,使用2019年更新的前列腺成像报告和数据系统2.1版(PIRADSv2.1)对前列腺进行3T多参数磁共振成像。此外,PIRADSv2.1还用于计算前列腺3T多参数磁共振成像的敏感性、特异性、阳性预测值和阴性预测值。我们在一家三级中心进行了一项回顾性研究,确定了在2019年6月至2021年6月期间接受前列腺活检并在同一机构进行了相应前列腺磁共振成像的患者,并根据PIRADSv2.1标准进行了评估。共有 50 名患者符合最终分析条件。前列腺癌的发病率为 69%(95% 置信区间 (CI) 54-81%)。使用 PIRADSv2.1 对前列腺进行 3T 多参数磁共振成像诊断前列腺癌时,生成了接收者操作特征(ROC)曲线;ROC 曲线下的面积为 0.81(95% CI 0.68-0.95,P < 0.001)。使用 PIRADSv2.1 的 3T 多参数前列腺 MRI 的灵敏度、特异性、阳性预测值和阴性预测值分别为 74.0%、87.0%、92.9% 和 59.1%。PIRADSv2.1 在诊断前列腺癌方面表现出良好的整体性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Egyptian Journal of Radiology and Nuclear Medicine
Egyptian Journal of Radiology and Nuclear Medicine Medicine-Radiology, Nuclear Medicine and Imaging
CiteScore
1.70
自引率
10.00%
发文量
233
审稿时长
27 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1